Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹7.1 L+₹3,110 (0.44%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹8.4 L+₹1.4 L (19.4%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹8.6 L+₹1.6 L (22.2%)Rejected-Finance NO 131 5TH CROSS PASCHIM COUNTY MEDARAHALLI CHIKKABANAVRA POST BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹8.6 L+₹1.6 L (22.3%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-Finance BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
14 Feb 2022, 6:00 pmClosed
AGE I AF CHIMNEY HILLS BANGALORE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINTENANCE AND REPAIR OF SOLAR STREET LIGHT AND SOLAR WATER HEATER, STREET LIGHTS AND OTHER MISC WORK AT 58 SU AF STATION CHIMNEY HILLS
2021_MES_498263_2
8492/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I AF CHIMNEY HILLS BANGALOR
₹15,000
Yes
25 Apr 2022
31 Jan 2022
16 Feb 2022
31 Jan 2022
14 Feb 2022
7 Feb 2022
31 Jan 2022 - 4 Feb 2022
Amount
Material and Labour for servicing of Solar street light fitting of 2x11/1x11 watt capacity including servicing of module cleaning, battery inspection, checking of distilled water in battery , inspection of electronic circuits etc.
Supply and Fix in repair battery box for battery housing suitable for solar light fittings
Supply and Fix in repair battery 110 AH 12 Volts suitable for solar lights
Supply and pore battery electrolyte (distilled water with acid) once in every quarter for each battery
Supply and Fix in repair luminaire assembley for 1x11 watt LED lamps (new solar light fittings) with complete accessories all as specified and as directed.
Material and Labour or repairs to solar water heater system by checking the leakage / sepage of the system if found rectified through the authorised dealers. Draining out the system by opening the cold water out let and hose to the bottom tank,dry out the system refilling the same after rectifing the leakes ,topping up with anti freeze solution of soft water,check the corrosion sacrificial anode,replace if found defective,clean the collector of capacity 100 LPD complete all as specified and as directed.
All as per Item ser No 6 here in before but capacity of 200 LPD
All as per Item ser No 6 here in before but capacity of 500 LPD
Supply and laying in repair CPVC pipes 20mm, SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S&F in repairs CPVC Ball valve suitable for 20mm dia pipe complete all as specified and directed
Supply and Fix framed work such as grills, gratings, etc., with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work confirming to Fe.290.Gde-E-165
M & L for preparation of new steel surface of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed
Supply and Fix in replacement of solar standalone street light having in-built SCC, 12 watts luminaire(one No.), system voltage 12 V, 60 Wp solar panel, Battery 40 Ah low maintenance lead acid tubular type, HDG tubular pole 5 mtr, etc including civil work for fixing the stand post complete all as specified and directed Make : Havells cat No SOLAR AIO 20 W or Eqvt
Supply and Fix in repair thoughened Glass 6mm for Solar Water Heater Flat Plate collector, fix and seal as recommended by the manufacturer and all as directed
Supply and fix in replacement LED street light 60 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 Make:- Havells Cat Part No ENDURAPEARLPLUSSL60WLED757SASYTOPC or equivalent in crompto/ Phillips
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core including dismantling of old U/S cable
All as per item no.16 above but 16 Sqmm 4 core
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of cable.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and lay brunt bricks class 'B' of standard size in trenches for protection of UG cable.
Supply and spread dry clean fine stone dust in trenches as cable cushioning to UG cable all as per clause 19.75 of SSR part -I
Supply and fix in repair GI tubing 40 mm bore, light grade fixed to wall/floor and laid in trench complete for cable protection including fixing arrangements.
Supply and fix for Hard PVC junction box (Make :- Sintex) of size 200x150x150 mm weather proof with bus bar for three phase and neutral link including MCB SP 6 Amps -1 No and necessary cable gland- 2 Nos for 10 sqmm 4 core cable and locking arrangement and fixing with existing PCC / steel tubler electric pole above the copping with suitable MS clamps, nuts & bolts and necessary electric connection etc.and necessary connection with suitable size cable complete all as directed .
Material and Labour for Aluminium painting to Steel tubular Street light pole for 5.5 mtr from top towards bottom and next 0.45 mtr Navy Blue and next 1.10 mtr white and 0.45 mtr Synthetic enameld paint yellow & black colour (Tiger cross) on Coping and writing pole No with white paint inside of black circle above the Navy blue painting and aluminium painting to GI bracket / pipe etc.and sticking of reflector stricker red in colour on the Poles at the height of 1.5 metre above the copping and all as specified and and as directed.
Material and Labour in replacement sub main wiring with two single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor FRLS cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit 20mm dia including accessories fixed on poles with proper bracings complete all as specified and directed. Note:- Two runs of 1.5 sqmm, one run of 1.5 sqmm conductors and one run of PVC conduit shall be measured as one unit
Replacement of unserviceable wire/cable from junction box to light fitting fixed on pole on existing PVC conduit by PVC insulated unsheathed copper conductor FRLS of 1.5 sqmm 2 runs. Note:- Two runs of 1.5 sqmm conductors shall be measured as one unit
Supply and errection of steel tubular swaged pole 09 M long type 410-SP-31 complete with CI base plate, finial taper plug, bolts, nuts and screws etc including necessary excavation and earth work, in loose/soft/hard soil of size 600 x 600 x 1500mm, PCC 1:3:6 type C-2 in foundation, PCC 1:2:4 type B-1 in plinth block/coping disposal of surplus soil up to 50 M, Painting inside with black bitumen paint and out side with two coats of aluminum paint over one coat of red oxide Primer and numbering of poles and block & white striping up to 1.5 Mtr height, 300mm wide complete all as specified and directed
Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick, burried directly in ground (earth pit not less than 2.25 Metre, deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4 mm dia thick galvanised earth wire by means of bolts, nuts, washers, check nuts of galvanised iron or steel all as specified or indicated including excavation and earth work PCC 1:2:4 type B-1(using 20 mm graded aggregate) in chamber RCC cover 40mm thick in 1:2:4 type B-1 (20mm graded aggregate) with 8 mm MS rod as 15cm in both ways with hooks, funnels with watering pipe, wire mesh and copper lugs,GI protection pipe and testing on completion.
KUZHIKKAL ENTERPRISES
manoj trading agencies
Aditya Associates
ANAND REFRIGERATION
VARGHESECHACKO AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .