GEMC-511687700521498
Awarded to CONCEPT ELECTRONICS PRIVATE LIMITED
₹2.8 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE Battery Analyzer | BT521 | - | 1 NOS | ₹2.8 L | 281,583 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.8 LQualified Make: FLUKE
Model: BT521 NO 1940 27TH CROSS 9TH MAIN NO 49 30TH CROSS 7TH BLOCK JAYANAGAR BANASHANKARI 2ND STAGE BANGALORE KARNATAKA 560070 | BENGALURU URBAN | KARNATAKA | 560070 | Make: FLUKE
Model: BT521 | L1 | Qualified | |
| 2 | Disqualified Make: ANALYTICAL
Model: APHY3056 ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: ANALYTICAL
Model: APHY3056 | - | Disqualified | |
| 3 | Disqualified Make: NA
Model: DIGITAL MULTI METER 21 C INDUSTRIAL ESTATE OPP POLICE LINE GANGA NAGAR | Make: NA
Model: DIGITAL MULTI METER | - | Disqualified | |
| 4 | Disqualified Make: KYORITSU
Model: KEW 1021R AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | Make: KYORITSU
Model: KEW 1021R | - | Disqualified | |
| 5 | Disqualified Make: RISHABH
Model: RISHABH 616 G F LEFT SIDE L 95 STREET NO 7 NEAR BENGALI DHABA MAHIPALPUR EXT SOUTH WEST DELHI DELHI 110037 UDYAM DL 10 0020521 | NEW DELHI | DELHI | 110037 | Make: RISHABH
Model: RISHABH 616 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
20 Sept 2018, 7:00 pmClosed
digital multimeter Average Turn Over of Last 3 Years 10 Lakh (s) Experience with Gov. Required 10 Year (s) Digital Multimeter ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 3.5 3.5
4.5
6.5 Measurement Type True RMS Average
True RMS Counts 6000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 600 600
1000 DC Voltage Accuracy 0.1 0.005
0.05
0.1
0.5
1 DC Voltage resolution 0.001 0.001
0.01
1
10
100 AC Voltage Range 600 600
1000 AC Voltage Accuracy 1 0.08
1 AC Voltage resolution 0.1 0.001
100 1/5 DC Current Range 10 3
10 DC Current Accuracy 1.5 0.005
1.5 DC Current resolution 100 0.001
100 AC Current Range 10 3
10 AC Current Accuracy 1.5 0.5
1.5 AC Current resolution 100 0.001
100 Resistance Range 40 40
50
60
100
500 Resistance Accuracy 1 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.001 0.001
100 Capacitance Range ( Micro farad ) NA 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) NA 1.5
3.5
5
NA Capacitance resolution ( nF ) NA 0.001
NA Frequency Range ( KHz ) NA 50
200
300
NA Frequency Accuracy ( % ) NA 0.1
NA Frequency resolution ( Hz ) NA 0.001
NA Temperature Range ( Degree C ) NA -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) NA 1.5
NA Temperature resolution ( Degree C ) NA 0.001
NA OTHER FEATURES Continuity test and Diode test Not Available * Data logging Available * If Data Logging Feature is Available
Internal Memory min. 5000 points/200 readings * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) 58 X 108 X 220 mm * Weight 850 * Other Features Measure Battery * 2/5 Internal Resistance
Battery Voltage
ACV
DCV
Ripple Voltage
ACA & DCA with Current Clamp
Meter & Sequence mode with Voltage and Resistance Threshold Limits to declare PASS/FAIL Indication
Auto HOLD & Save
with Software and USB Cable to transfer Data to PC SAFETY Safety Rating Category III 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification CE * POWER REQUIREMENTS Power Requirements Battery Operated * if Battery Operated
then Type of Battery Rechargeable * if rechargeable
then chemistry of the battery lithium ion * if Non-rechargeable
then size of the battery cell NA * number of non- rechargeable the battery/cell 1 * Voltage of rechargeable Battery 7.4 * capacity of rechargeable battery(milli Ampere Hour) 3000 * Suitable charger adaptor provided YES * ACCESSORIES Standard Accessories Supplied with the Equipment Battery Analyzer Test Leads with 4wire test pin
Interactive Test Leads (4 wire test pin) with Temperature Sensor
Voltage to Current Adapter with basic multimeter Test Leads with AC/DC * 3/5 Current Probe
Mains Adapter with Internal Battery
Magnetic Hanger with Soft Carry Case
USB Cable with Software
long length Test probes
4 wire pin set and fuses (2 no) WARRANTY Warranty 3 1
5 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Condition 50 * Operating Humidity (RH) 80 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest false * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest false * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH false * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test 45213 15-06-2018 * Name and address of the Lab for the specification test TRANSCAL Ltd
Bengaluru * * Bold specifications are the golden parameters. Consignees and Quantity 4/5 S.No. Consignee Address Quantity Delivery Days 1 Desu Saikumar 560038
Old Madras Road
Near NGEF Bus Stop
Baiyappanahalli 1 15
621762
GEM/2018/B/88275
GeM Contract
digital multimeter
GeM Contract
15 days
Karnataka; Bengaluru Urban
PRODUCT
Awarded to CONCEPT ELECTRONICS PRIVATE LIMITED
₹2.8 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE Battery Analyzer | BT521 | - | 1 NOS | ₹2.8 L | 281,583 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter Average Turn Over of Last 3 Years 10 Lakh (s) Experience with Gov. Required 10 Year (s) Digital Multimeter ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 3.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type True RMS Average | - | - | - |
| True RMS Counts 6000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 600 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.1 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 0.001 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 600 600 | - | - | - |
| 1000 AC Voltage Accuracy 1 0.08 | - | - | - |
| 1 AC Voltage resolution 0.1 0.001 | - | - | - |
| 100 1/5 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 1.5 0.005 | - | - | - |
| 1.5 DC Current resolution 100 0.001 | - | - | - |
| 100 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 1.5 0.5 | - | - | - |
| 1.5 AC Current resolution 100 0.001 | - | - | - |
| 100 Resistance Range 40 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.001 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) NA 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) NA 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) NA 0.001 | - | - | - |
| NA Frequency Range ( KHz ) NA 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) NA 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) NA 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) NA -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) NA 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) NA 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Not Available * Data logging Available * If Data Logging Feature is Available | - | - | - |
| Internal Memory min. 5000 points/200 readings * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) 58 X 108 X 220 mm * Weight 850 * Other Features Measure Battery * 2/5 Internal Resistance | - | - | - |
| Battery Voltage | - | - | - |
| ACV | - | - | - |
| DCV | - | - | - |
| Ripple Voltage | - | - | - |
| ACA & DCA with Current Clamp | - | - | - |
| Meter & Sequence mode with Voltage and Resistance Threshold Limits to declare PASS/FAIL Indication | - | - | - |
| Auto HOLD & Save | - | - | - |
| with Software and USB Cable to transfer Data to PC SAFETY Safety Rating Category III 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification CE * POWER REQUIREMENTS Power Requirements Battery Operated * if Battery Operated | - | - | - |
| then Type of Battery Rechargeable * if rechargeable | - | - | - |
| then chemistry of the battery lithium ion * if Non-rechargeable | - | - | - |
| then size of the battery cell NA * number of non- rechargeable the battery/cell 1 * Voltage of rechargeable Battery 7.4 * capacity of rechargeable battery(milli Ampere Hour) 3000 * Suitable charger adaptor provided YES * ACCESSORIES Standard Accessories Supplied with the Equipment Battery Analyzer Test Leads with 4wire test pin | - | - | - |
| Interactive Test Leads (4 wire test pin) with Temperature Sensor | - | - | - |
| Voltage to Current Adapter with basic multimeter Test Leads with AC/DC * 3/5 Current Probe | - | - | - |
| Mains Adapter with Internal Battery | - | - | - |
| Magnetic Hanger with Soft Carry Case | - | - | - |
| USB Cable with Software | - | - | - |
| long length Test probes | - | - | - |
| 4 wire pin set and fuses (2 no) WARRANTY Warranty 3 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Condition 50 * Operating Humidity (RH) 80 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest false * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest false * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH false * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test 45213 15-06-2018 * Name and address of the Lab for the specification test TRANSCAL Ltd | - | - | - |
| Bengaluru * * Bold specifications are the golden parameters. Consignees and Quantity 4/5 S.No. Consignee Address Quantity Delivery Days 1 Desu Saikumar 560038 | - | - | - |
| Old Madras Road | - | - | - |
| Near NGEF Bus Stop | - | - | - |
| Baiyappanahalli 1 15 | - | - | - |
Exempted
22 Sept 2018
17 Sept 2018
contract_GEMC-511687700521498.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_621762.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .