Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC | ₹6.4 Cr | L1 | Accepted-AOC QUOTED L1 |
| 2 | L2₹7.0 Cr+₹62.0 L (9.72%)Rejected-AOC 3 KHATAU APARTMENT TILAK ROAD JOSHI LANE GHATKOPAR EAST MUMBAI 400 077 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | ₹7.0 Cr+₹62.0 L (9.72%) | L2 | Rejected-AOC NOT ADMITTED |
| 3 | L3₹7.1 Cr+₹77.0 L (12.1%)Rejected-AOC | ₹7.1 Cr+₹77.0 L (12.1%) | L3 | Rejected-AOC NOT ADMITTED |
| 4 | L4₹7.3 Cr+₹91.2 L (14.3%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹7.3 Cr+₹91.2 L (14.3%) | L4 | Rejected-AOC NOT ADMITTED |
| 5 | L5₹7.5 Cr+₹1.1 Cr (17.0%)Rejected-AOC 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹7.5 Cr+₹1.1 Cr (17.0%) | L5 | Rejected-AOC NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹7.5 L
Closing Date
20 Oct 2021, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
DEMOLITION AND RECONSTRUCTION OF BLDG P-3 AND P-4 UNDER GE NW MANKHURD
2021_MES_466381_1
8803/E8
Open Tender
Civil Works
Lump-sum
450 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (NW) MANKHURD
₹7.5 L
Yes
26 Nov 2021
10 Aug 2021
21 Oct 2021
10 Aug 2021
20 Oct 2021
3 Oct 2021
Amount
SCH 'A' PART-I : "BUILDING WORKS" Total of Schedule 'A' Part-I brought forwarded from Serial Page No. 27(R)(R).
SCH 'A' PART-II "EXCAVATION AND EARTH WORK " Total of Schedule 'A' Part-II brought forwarded from Serial Page No. 28(R).
SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Schedule 'A' Part-III brought forwarded from Serial Page No. 29(R).
SCH 'A' PART-IV "INTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-IV brought forwarded from Serial Page No. 30(R)(R) to 33(R)(R).
SCH 'A' PART-V "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-V brought forwarded from Serial Page No.34(R)(R) to 37(R)(R).
SCH 'A' PART-VI "EXTERNAL WATER SUPPLY" Total of Schedule 'A' Part-VI brought forwarded from Serial Page No. 38(R).
SCH 'A' PART-VII "ROAD/PATH/CULVERT" Total of Schedule 'A' Part-VII brought forwarded from Serial Page No. 39(R)
SCH 'A' PART-VIII "SEWAGE DISPOSAL" Total of Schedule 'A' Part-VIII brought forwarded from Serial Page No. 40 (R)(R) to 41(R)(R).
SCH 'A' PART-IX "AREA DRAINAGE" Total of Schedule 'A' Part-IX brought forwarded from Serial Page No. 42(R).
SCH 'A' PART-X "COMPOUND WALL" Total of Schedule 'A' Part-X brought forwarded from Serial Page No. 43(R) to 45(R).
SCH 'A' PART-XI "RETAINING WALL" Total of Schedule 'A' Part-XI brought forwarded from Serial Page No. 46(R).
SCH 'A' PART-XII "DEMOLITION" Total of Schedule 'A' Part-XII brought forwarded from Serial Page No. 47(R).
SCH 'A' PART-XIII "MISC WORKS"
"EXTERNAL ELECTRIC SUPPLY"
Supply and Installation of 11 KV Outdoor type package substation with facility for internal lighting, earthing, padlocks etc. Connection between air insulated switchgear & transformer shall be using 3 nos. 1C X 185 sq.mm. Aluminium unarmored (E) XLPE cable and connections from Transformer to LT Panel shall be by Aluminium Bus bar with Outdoor Type 3.0 mm thick M.S Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer Compartment. The enclosure exterior shall be powder coated with PP based paint. HT & LT compartment will be provided with the door and pad locking arrangement, including PCC foundation of dimension as per manufacturer's recommendation. Transformer Compartment will be provided with Cover. The Compartment illumination lamp with door operated switch shall be provided for HT and LT compartment. Lifting (Bucket) Arrangement shall be provided with each PSS. (A) HT Switchgear-: 11kV, 630Amps 21kA for 1 sec., Fixed type Schneider SF6 Breaker, Indoor , Manual, Non‐Extendable with 01 Incoming & 01 Outgoing to Transformer with self‐ powered series trip microprocessor base numerical over current & earth fault relay (IDMTL+Inst.) for protection of transformer‐ RT2
(B) Transformer -: TRANSFORMER (Manufactured as per IEC) -: Air cooled i) Applicable Standard : IS 11171 ii) Type : Cast Resin Dry Type iii) Rated kVA : 630 kVA iv) Rated Voltage Ratio : 11000/433 VOLT v) Rated Frequency : 50 Hz vi) Insulation Class : Class F vii) Winding Material : Copper viii) Vector Group : Dyn11 ix) Cooling : Air Natural x) Tappings on HV Side: +5 % to ‐10 % In step of 2.5 % xi) Losses : : No load Losses at Rated Voltage and Frequency : As per IS 2.6KW xii) Full load losses at rated current ,rated frequency and at 75 Degree.C ref temperature and at principal tap : As per IS 6.5KW xii) Temperature Rise by winding resistance method over 50 Degree.C of Ambient : 90 Degree.C (C) LT Busbar-: Main Busbar are of Aluminium however Copper Flexible are provided between Transformer & LT Incomer Connection alongwith Main Busbar, Voltage Rating‐ 415V, Current Rating ‐ 1000A. (D) LT PANEL-: 1000A 4P Fixed Type ACB with Micro Processor based OC+EF+SC relay On, OFF, TRIP lamps 1000/1 Amps Ring type CT for metering, R/Y/B indicating lamps and Multi Function Meter ‐EM64XX.
Notes-: For ittem no 14.01 to 14.03 (i) The drawing and specifications of the PSS and VCB and its components shall be got approved by the contractor from the GE before procurement. (ii) The PSS and VCB shall be got inspected and tested in the factory by the rep nominated by the AO before delivery from factory. The records of the testing shall be signed by the rep of the AO, contractor and rep of manufacturer. (iii) Cost of provision of any other misc accessories, components, parts other than those mentioned above in case technically required as per manufacturers instructions/ directions of GE to make the panel functional in all respects has to be provided and cost shall also be deemed to be included in the quoted rates. (iv) The Enclosure shall be factory fabricated from one ot the manufacturer mentioned for PSS and VCBs in Make list or their any other approved ranchise having CPRI approval certification subject to prior written approval of GE (v) The PSS and VCB after installation shall also be got tested at site by the rep nominated by the accepting officer and the records of the testing shall be signed by the rep of AO, GE, Engr-in-charge and the contractor. (vi) All the arrangements and testing equipments etc for testing as per note (ii) & (v) above shall be provided by the contractor and cost of the same shall be deemed to be included in the contractor's quoted rates. Note-: VCB to be coupled with existing VCB shall be provided with bus bar extension box including bus bar of same rating.
Supply and lay cable XLPE Insulated screened PVC bedded, unarmored, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 10 Sqmm 4 Core complete all as specified and directed( For UPS).
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through/end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armored, Al conductor cable of size 500 to 630 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply install, test and commissioning LT Panel board (CPRI Approved) Powder coated cubical type Indoor factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accommodate all accessories/fittings, compartmentalized in construction to accommodate all accessories. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colourcoaded sleeves. The cubicle shall have a bottom channel of size not less than 65 x 50 mm. A detachable predrilled powder coated gland plate should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. Adhesive type gasket shall be used to make panel vermin proof , complete as specified and consisting the following :( Location-: Bldg no. P-4). i) Busbar Copper TPN 1500 Amps -1 Set of 4 Nos. ii) ACB 1000 Amp 50 KA TP, EOD, Thermal Magnetic type - 1 Nos (Incommer) iii) MCCB 500-630 Amp 50 KA TP, Thermal Magnetic type - 2 Nos (UPS Panel and BBT) iv) MCCB 250-320 Amp 36 KA TP, Thermal Magnetic type - 1 Nos (AC plant panel) v) MCCB 125 Amps 36 KA TP, Thermal Magnetic type - 1 Nos (TS Hall Panel ) vi) MCCB 63 Amps 18KA TP, Thermal Magnetic type - 1 (Spare) vii) MCB 40 Amps 10KA TP - 1 (Spare) viii) MF Meter of 4410 Series -01 Nos ix) Indicating Lamps LED Type-03 Nos Note –: The Lay out drawing of the panel shall be got approved by the contractor from GE before the panel fabrication work.
All as per item no 14.07 but with the following acessories ( Location-: Bldg No. P-3) i) Busbar Copper TPN 1500 Amps -1 Set ii) Air Circuit Breaker 1000 Amps, FP 50 KA, EOD, Thermal Magnetic type -2 Nos iii) On load Change Over 4 Pole 1000 Amps - 1 Nos iv) MCCB 500-630 Amp 50 KA TP, Thermal Magnetic type - 2 No (UPS Panel and BBT) v) MCCB 250-320 Amp 36 KA TP, Thermal Magnetic type - 1 No (AC plant panel) vi) MCCB 125 Amps 25 KA TP, Thermal Magnetic type - 1 No (TS Hall Panel) vii) MCCB 63 Amps 16 KA TP, Thermal Magnetic type - 1 No viii) MCB TPN 40 Amps - 1 No ix) Indicating Lamps LED Type-03 Nos x) MF Meter of 4410 Series -01 No
Supply install, test and commissioning LT Panel board (CPRI Approved) Powder coated cubical type Indoor factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accommodate all accessories/fittings, compartmentalized in construction to accommodate all accessories. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colourcoaded sleeves. The cubicle shall have a bottom channel of size 50x50 mm. A detachable predrilled powder coated gland plate should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. Adhesive type gasket shall be used to make panel vermin proof , complete as specified and consisting the following (Loaction-:UPS Panel). i) Busbar Copper TPN 1000 Amps -1 Set ii) MCCB TP 500-630 Amps 50 KA, Thermal Magnetic type - 01 Nos iii) MCCB FP 50-63 Amps 18 KA, Thermal Magnetic type - 14 Nos iv) MCB SPN 32 Amps - 02 nos v) MF Meter of 4410 Series -01 No vi) Indicating Lamps LED Type-03 Nos
Supply install, test and commissioning LT Panel board (CPRI Approved) Powder coated cubical type Indoor factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accommodate all accessories/fittings, compartmentalized in construction to accommodate all accessories. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channelof size 50x50 mm. A detachable predrilled powder coated gland plate should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. Adhesive type gasket shall be used to make panel vermin proof , complete as specified and consisting the following (Loaction-:TS Hall panel). i) Busbar Copper TPN 320 Amps -1 Set ii) MCCB FP 200 Amps 36 KA, Thermal Magnetic type - 01 Nos iii) MCCB FP 40 Amps 18 KA, Thermal Magnetic type - 02 Nos iv) MCB TPN 63 Amps - 05 Nos v) MCB SPN 40 Amps - 02 nos vi) MF Meter of 4410 Series -01 No vii) Indicating Lamps LED Type-03 Nos
Supply Installation , Testing and Commissioning of 630A Aluminium Sandwich Type Construction 3P4W 100%N Body Enclosure as Integral Earth Operating Voltage 1000V Suitable for 50 / 60 Hz with impulse withstand voltage of 12kV, Insulation Voltage 1000V Rated Short time Current 36kA for 1 Sec .Overall Dimension Of 130x130mm. aluminium conductor with CU coating on entire surface, insulated with red class F thermosetting plastic material and factory fitted in one side of the each trunking components. The enclosure shall provide a protection not less than IP- 55 as per IEC-60529 for indoor application for both Feeder and Distribution elements. The busbar Trunking shall comply with standard IEC 61439-6 and the rated current of the busbar trunking systems shall be referred to the average ambient temperature of 40 °C .The Bus duct enclosure consists of four C-ribbed section bars, bordered and riveted, with excellent mechanical, electric and heat loss efficiency.The sheet metal is made of 1.5 mm thick hot-galvanizes steel treated according to UNI EN 10327 and painted with RAL7035 resins with high resistance to chemical agents.The enclosure shall provide a protection of IK 10 against mechanical impact.The enclosure paint shall have maximum resistance to corrosion with salt spray life of 1500hrs. Tapoff Box with Mechanical Interlocking Feature for MCCB Power Isolation in Incomer busbar on Door Opening with the following accessories including fabrication cost complete all as specified and directed. Make : L&T, Legrand C&S, Schneider. i) straight feeder plug in feeder ii) Flange End iii) Elbow 90 degree iv) Spring Hanger (Vertical run) v) Edgewise Hanger (Horizontal run) vi) End Cover vii) Tee Elbow viii) Copper flexible (Braided) ix) Adopter Box x) 4 Pole plug in box - 28 Nos xi) MCCB 63 Amp, 415 V, 4 pole with spreader terminal- 28 Nos Note-: All miscellaneous accessories required at site during execution, though not mentioned in above description but technically required shall be provided and rate shall be inclusive in the quoted rate.
Supply and fix on load changeover switch of capacity 63 Amps with enclosure including such as Hinges,nut,bolts,washers,clamps etc
Supply and fix GI cable tray of thickness 16 SWG and size 300mm x 50mm depth with cover including all coupler plates, hanger hinges, nut, bolts, washers, clamps etc
Supply and fix GI cable tray of thickness 16 SWG and size 300mm x 25mm depth with cover including all coupler plates, hanger hinges, nut, bolts, washers, clamps etc
Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom & 70mm top made up of 3 mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 Nos of M20 x 600 long J type foundation bolts and one mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed.
M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrolyte not less than 50 Kg buried directly in ground including earth bore hole work (earth bore of size 150mm dia and not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) In -Pipe Technology, Designed & Manufactured using M.S Pipes, Outer Dia is 50 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrolyte backfill: Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size: 25 kilograms, Recommended for normal soil conditions. Conforms to IS : 3043 – 1987. Make: Ashlok or any ISO Certified approved make.
Supply and installation Servo Controled Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 25 KVA, including filling of oil, connection to LT panels and including the following acessories & Functions and all as specifiec and directed. (i) LCD Display Displaying Date, Time, Input Voltage, Out Put Voltage (ii) Log Book Memory (iii) Programmable Features (Cut OFF Voltage, Over load Trip,Time Delay set, Operation Mode Auto/Manual) (iv) Protection - Automatic Switch Off against under voltage, over voltage, over load, short circuit & Single phasing
"EXTERNAL WATER SUPPLY"
Cutting of existing CI pipe 80mm bore in position for inserting DI Tee of size 80 x 80 x 80 mm complete all as directed for taking 80 mm dia DI branch line complete all as specified and directed.
Supply, laying, connect and testing DI water tubing of 80 mm bore with spigot and socket ends class K-9 conforming ti IS:8329 /2000 in any length suitable for rubber tyton joint including one rubber joint laid in trench complete all as specified and directed.
M & L for DI fittings class K-12 conforming to IS:9523/2000 upto 100mm dia of any type, size, such as bend, tapper, tee piece, cross etc complete all as specified and directed.
Meterial and labour for construction of block masonary valve pit of size 100cmx100cmx100cm (internal dimension) and MS plate cover not less than 3 mm thick with angle iron frame of size 45 x 45 x 5mm thick, including all hings and locking arrangements and handle including necessary excavation in any type of soil, returning filling in and removal of surplus soil to distance not exc 50 mtr, rendering block masonary wall plaster in cement motor (1:4) (internaly/externaly) and applying two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces etc complete all as specified and directed.
Hem Construction Company
Nexus Infratech
Vishal Builders
surendra infrastructure pvt ltd
MUKESH CONSTRUCTION CO
United Sales Corporation
Parmatma Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .