Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹3.3 Cr+₹17.7 L (5.76%)Rejected-Finance | ₹3.3 Cr+₹17.7 L (5.76%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹3.3 Cr+₹22.5 L (7.30%)Rejected-Finance | ₹3.3 Cr+₹22.5 L (7.30%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹3.4 Cr+₹36.6 L (11.9%)Rejected-Finance | ₹3.4 Cr+₹36.6 L (11.9%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹3.5 Cr+₹40.3 L (13.1%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹3.5 Cr+₹40.3 L (13.1%) | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
24 Oct 2020, 6:00 pmClosed
Chief Engineer lucknow Zone
17, Cariappa Marg, Cantonment, Lucknow -226002
AUGUMENTATION OF ELECTRIC SUPPLY AT MH AGRA UN-DER GE (EAST) AGRA
2020_MES_371937_1
CELZ/AGR/T-05 of 2020-2021
Open Tender
Civil Works
Lump-sum
450 days
Agra
As per NIT
7 documents required · 7 mandatory
₹2,000
GE(E) Agra
₹5 L
Yes
14 Dec 2020
25 Aug 2020
26 Oct 2020
25 Aug 2020
24 Oct 2020
7 Oct 2020
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Construction of Sub Station building complete all as shown on drawings and specified.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply)
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Sewage Disposal)
Total amount of Sch 'A' Part VI (Fencing & Gate)
Total amount of Sch 'A' Part VII (External Electrification)
Schedule 'A' Part - VIII (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 signifies this fact only.
INTERNAL ELECTRIFICATION Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit 25 mm dia medium grade in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.
Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit 25 mm dia medium grade in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.
M&L for point wiring complete with PVC insulated and unsheathed,FRLS cable 2.5 sqmm (nominal area) ,ISI marked,stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floorslab,pressed GI concealed termined boxes not less than 1.6mm thick of required size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 2.5 Sqmm,FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified.
Energy saving 2 feet LED batten tube light fitting with high brightness 9 Watt LED retrofit rod with a nominal system output of 120 lim/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000Kintegrated high efficiency LED drive>85% non corrosive including PVC insulated three core 23/0.0076 copper cable and including suitable size of pvc flexible conduit from celling rose to tube light fitting complete with ISI marked all as specified and directed Make-Philips/Crompton/Bajaj
Retrofit LED light fitting,1X20 Watt,(min 120 lim/watt) 230 volts, 4 feet ,energy efficient type,ceiling /wall mounting, box type fitting, with epoxy powder coated CRCA sheet housing with reflector cover channel,complete with all accessories internaly prewired with 1 No LED 28 watt tube rod including including PVC insulated three core 23/0.0076 copper cable and including suitable size of pvc flexible conduit from celling rose to tube light fitting complete ISI Marked all as specified and directed. Make Philips cat part No LT4F20WLEDT8/WD or equivalent in Bajaj/Crompton
LED security light 25 watt ,5700K made out of pressure die cast aluminium housing with toughned glass , IP66 protection and impact resistance IK07 ,fixed with wall with cap type bracket having length not less than 0.31 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light . including PVC insulated three core 23/0.0076 copper cable and including suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed by Engr-In-Charge.Make: Havells cat part No- LHETAXU7PA6S025 or equivalent in Philips and Crompton/Bajaj.
Ceiling fan 1200 mm sweep single phase 230V AC, five star BLDC fans ISI marked rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long for connection complete all as specified.Make Bajaj model Electra 50 or equivalent in Philips/Crompton.
Exhaust Fan high quality engineering plastic, resistant to colour change with anti- static properties (ventil air) 200 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from ceiling rose to exhaust fan motor complete all as specified and directed. Make- Usha/Baja/havells/CG.
Exhaust Fan high quality metallic body, resistant to colour change 450 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from ceiling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model no Supreme Dlx /havells/CG
MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked all as specified and directed . Make:Schneider/Siemens/ABB
MCB single pole 2 Amp rating 'C' Series,10 KA 240 Volts,AC 50 Hz ,ISI marked all as specified and directed . Make:Schneider/Siemens/ABB
MCB single pole 2 Amp rating C' Series ,10 KA 240 Volts,AC .,50 Hz ISI marked all as specifed and directed . Make:Schneider/Siemens/ABB
MCB single pole 6 Amp rating 'C' Series ,10 KA 240 Volts,AC ., 50 Hz ISI marked all as specified and directed . Make:Schneider/Siemens/ABB
MCB SPN 16 Amps 'C" series,,10 KA 240 Volts ,AC , 50 Hz ISI marked all as specifed and directed. Make:Schneider/Siemens/ABB
Submain wiring with two single core 4 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified.(For connection to flood light) Note:- Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.
Supply and laying 11 KV (Earthed) , aluminium conductor, screened, XLPE insulated , armoured shielded and PVC sheathed cables ISI marked, IS 7098 (Part-II) amended upto date triple entruded, cross sectional area 120 Sqmm, 3 Core complete all as specified and directed.
Supply and fixing on existing pole and testing 11 KV ( earthed ) grade AB cable comprise three single power core stranded aluminium conductor 185 sqmm cables screened with black extruded semi conducting compound, natural coloured, XLPE insulated core sreened with black extruded semi conducting compound and one layer of copper tape and coloured with black extruded PVC ( core identification by colour tape, marking red, yellow and blue placed longitudinally under the copper tape ) and twisted around non compacted circular aluminium alloy a base messenger wire 150 sq mm, ISI Marked , IS : 8130-1984, IS-398(Part-IV)-1994, IS : 7098(Part II) & IS-5831-1984 with upto date amendment and including supporting hardware such as clamps, insulators etc as per manufacturer instructions to fix ed on existing polecomplete .
Supply, jointing and testing straight through cold shrinkable joint including all materials and accessories suitable for 3 core x 120 sqmm to 3 core 185 Sq mm XLPE armoured/AB cable aluminium conductor cable of 11000 Volt grade all as per manufacturers recommendation complete all as specified and directed. Make : Dension/M Seal/Cab Seal.
Supply, jointing and testing indoor type cold shrinkable end terminal cable joint including all materials and accessories suitable for 3 core x 120 to 185 sqmm XLPE armoured/AB aluminium conductor cable of 11 kV grade all as per manufacturers recommendation complete all as specified and directed. Make : Dension/M Seal/Cab Seal
Supply, jointing and testing outdoor type cold shrinkable end terminal cable joint including all materials and accessories suitable for 3 core x 120 to 185 sqmm XLPE armoured/AB aluminium conductor cable of 11 kV grade all as per manufacturers recommendation complete all as specified and directed. Make : Dension/M Seal/Cab Seal
Supply, install, test & commissioning of HT 11 KV, 630 Amps, VCB( Vaccum circuit braker - 09 Nos ( as two nos Incomer, one no bus coupler and six nos out going feeder ) ICOG panel indoor type totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltag rated should be used.back entry type complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. The switchgear and control gear panels shall be of the fully arc proof LSC 2B, PM, IAC AFLR for 26.3 kA for 3 Sec complete all as specified and as directed. The VCB and VCB Panel should be similar make only and comprising of the following accessories consisting as per details mentioned in Annexure - "A" to BOQ. NOTE :- (i) Annexure- "A" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Disconnect carefully and shifting of Transformer 11KV/415 volt, 400/500 KVA to new location using special T&P and making connections means electrically and mechanically to make it functional complete including foundation and platform with step of size 2.5 mtr x 2.0 mtr x 1.5 mtr height made out of brick construction including excavation, PCC and rendering etc as per existing pattern complete all as per drawing No TD-699 sheet 1/1 and related TD drgs and dismentling existing plateform etc complete all as specified and directed.
Disconnect carefully and shifting of Transformer 11KV/415 volt, 400/315 KVA to new location using special T&P and making connections means electrically and mechanically to make it functional complete including foundation and platform with step of size 2.5 mtr x 2.0 mtr x 1.5 mtr height made out of brick construction including excavation, PCC and rendering etc as per existing pattern complete all as per drawing No TD-699 sheet 1/1 and related TD drgs and dismentling existing plateform etc complete all as specified and directed.
Disconnect carefully and shifting of DG set 500 KVA, panel board alongwith voltage stabiliser to new location using special T&P and making connections means electrically and mechanically to make it functional complete including PCC foundation plateform (1:2:4,M20 grade) of weight 2.5 times of the operating weight of DG set and approximate depth of 200 mm below ground surface and height of minimum 150 mm above ground surface is required so as to provide leveled surface for placement of the acoustic enclosure.The length and breadth of the plateform shall be atleast 250mm more than the size of enclosure .Genset shall be mounted on AVMs inside the enclosure.The plateform levels to be checked diagonally as well as across the length for even flatness.The plateform shall be within +/- 0.5 degrees (angle) of any horizontal plane.The contractor shall submit the drawing to Engineer in charge for approval before proceeding with the work complete all as specified and directed.
Supply, installation, commissioning and testing of transformer copper wound step down 630 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed air naturally cooled (ONAN Type), with external cooling tubes/radiators, Double wound core type copper wound having no load voltage ratio 11 KV/415 Volts corresponding to principal tapping,delta connected primary side (HV Side) and star connected on secondary side (LV Side) in accordance with vector symbol DYN 11 (Vector group-4) with neutral brought out on LV side and having tapping on HV side for constant out put so as to alter vary secondary voltage from ± 2 ½ %, ± 5% and ± 7 ½ % in step to be changed by mean of manual off load tap changing arrangements complete confirming to IS-1180 Pt-I 2014 all as specified. The transformer shall comprise of the following accessories consisting as per details mentioned in Annexure - "B" to BOQ. NOTE :- (i) Annexure- "B" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. -
Supply,installation,testing & commissioning of 11 KV Outdoor type 05 way RMU (at main gate near FON JCO mess) extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-03 nos as incomer and fixed type Motorised Vacuum Circuit Breakers-02 nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. . RMU should be tested for an internal arc fault of 21kA for 3 sec. for tank holding the HV components/cable box and paint shade and thickness should be as per AIS 632 IS -5. . RMU should be complete with following accessories consisting as per details mentioned in Annexure - "C" to BOQ. NOTE :- (i) Annexure- "C" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. Note for item No 8.26 to 8.28: i) Make of various components / accessories to be used and incorporated in the RMU shall be as recommended by OEM . ii) the complete enclosure with all accessories and breakers shall be of OEM only . No channel partner panel fabrication is permitted.
Supply,installation,testing & commissioning of 11 KV Outdoor type 04 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-02 nos as incomer and fixed type Motorised Vacuum Circuit Breakers-02 nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376,60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. RMU should be complete with following accessories consisting as per details mentioned in Annexure - "D" to BOQ. NOTE :- (i) Annexure- "D" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. -
Supply,installation,testing & commissioning of 11 KV Outdoor type 05 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-02 nos as incomer and fixed type Motorised Vacuum Circuit Breakers-03 nos as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to ful fill the requirement as per IEC 60376,60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. RMU should be complete with following accessories consisting as per details mentioned in Annexure - "E" to BOQ. NOTE :- (i) Annexure- "E" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning of SF6 CIRCUIT BREAKER 630 Amps ( Out door ), 12 kV, 50 Hz, lightning impulse 75 KV peak ( outdoor type ) with IP 54 protection SF 6 insulated compact switch gear equipped according to international standered ICE 62271-200 intensive to environmental conditions in compact version with stainless steel tank and comprising, 630 Amps LOAD BREAK SWITCH and protective relays for adjustable relay to protect transformer upto 200 to 615 KVA alongwith compact battery , cable termination from the front of side/back side, breaking capacity min 20/21 kA/3 sec enclseod in metallised cast resin/stainless steel enclosure, complete all as specified and tested as per latest IEC rules 62271-200 complete. Make-ABB/Schineider/C & S/ Siemens.
Supply, installation, testing and commissioning outdoor type cubicle Panel board CPRI approved and extensible on both sides made out of 3.15 mm thick CRCA sheet steel & MS angle section 50 x 50 x 6mm and leg length should not be less than 90 cm,out of which 45 cm should be above ground frame with front & back openable, double door system lockable / openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air "U" type gasket suitable for 3 phases, 4 wire, design verified as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA with internal arc containment with IP 54 protection, with electrical grade aluminum for rated continuous current of 1500 Amps for main bus bar with 65 KA rated short time current (rms) for 1 sec & 105 KA (Peak) rated dynamic short circuit withstand with heat shrinkable sleeving along with shrouds for joints and earth bus bar of aluminum 50 x 10 sqmm size (min) with short circuit rating of 30 KA for 1 sec, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shade of RAL-7035 provided with suitable gasket to make it dust / vermin proof & general construction comprising of the following accessories consisting as per details mentioned in Annexure - "F" to BOQ. NOTE :- (i) Annexure- "F" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. -
Supply, installation, testing and commissioning outdoor type cubicle Panel board CPRI approved and extensible on both side made out of 3.15 mm thick CRCA sheet steel & MS angle section 50 x 50 x 6mm and leg length should not be less than 90 cm,out of which 45 cm should be above ground frame with front & back openable, double door system lockable / openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air "U" type gasket suitable for 3 phases, 4 wire, design verified as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA with internal arc containment with IP 54 protection, electrical grade aluminum for rated continuous current of 1000 Amps for main bus bar with 65 KA rated short time current (rms) for 1 sec & 105 KA (Peak) rated dynamic short circuit withstand heat shrinkable sleeking along with shrouds for joints and earth bus bar of aluminum 50 x 10 sqmm size (min) with short circuit rating of 30 KA per sec, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shade of RAL-7035 provided with suitable gasket to make it dust / vermin proof & general construction comprising consisting of the following accessories consisting as per details mentioned in Annexure - "G" to BOQ. NOTE :- (i) Annexure- "G" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. -
Supply, installation, testing and commissioning outdoor type cubicle Panel board CPRI approved and extensible on both side made out of 3.15 mm thick CRCA sheet steel & MS angle section 50 x 50 x 6mm and leg length should not be less than 90 cm,out of which 45 cm should be above ground frame with front & back openable, double door system lockable / openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air "U" type gasket suitable for 3 phases, 4 wire, design verified as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA for 1 sec & rated with internal arc containment with IP 54 protection, with electrical grade aluminum for rated continuous current of 600 Amps for main bus bar with 65 KA rated short time current (rms) for 1 sec & 105 KA (Peak) rated dynamic short circuit withstand heat shrinkable sleeking along with shrouds for joints and earth bus bar of aluminum 50 x 10 sqmm size (min) with short circuit rating of 30 KA per sec, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 micron with paint shade of RAL-7035 provided with suitable gasket to make it dust / vermin proof & general construction comprising of the following accessories consisting as per details mentioned in Annexure - "H" to BOQ. NOTE :- (i) Annexure- "H" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. -
Supply, installation, testing and commissioning outdoor type cubicle Panel board extensible on both side made out of 3.15 mm thick CRCA sheet steel & MS angle section 50 x 50 x 6 mm frame with front & back openable, double door system lockable / openable by keys from both sides having flush pattern fency locks with louvers & air vent gasket for natural flow of air "U" type gasket suitable for 3 phases, 4 wire, design verified as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA with internal arc containment with IP 54 protection rupturing capacity at 415 volts, electrical grade aluminum for rated continuous current of 200 Amps for main bus bar with 65 KA rated short time current (rms) for 1 sec & 105 KA (Peak) rated dynamic short circuit withstand heat shrinkable sleeking along with shrouds for joints and earth bus bar of aluminum 50 x 10 sqmm size (min) with short circuit rating of 30 KA per sec, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust / vermin proof & general construction comprising of the following consisting as per details mentioned in Annexure - "I" to BOQ. NOTE :- (i) Annexure- "I" to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. -
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 500 sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 400 sq mm 3.5 core complete all as specified and directed
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 240 sq mm 3.5 core complete all as specified and directed
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 185 sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 120 sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 95 sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 50 sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty)1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 35 sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade ISI marked as per IS-7098 Part-I with stranded aluminium conductorthrough pipe/road crossing in ducts, on poles, trenches etc of size 16 sqmm 3.5 core complete all as specified and directed.
Busbar chamber of capacity 200 A, 4 Nos, 415 V , 50 Hz, on wall /pole/panel with proper lugs having 4 Nos of copper bus bars complete all as specified and directed. (Make SHI, HPL, Havells/Shallab) .
Busbar chamber of capacity 315 A, 4 way, 415 V 4 pole, 50 Hz, on wall /pole/panel with proper lugs having 4 Nos of copper bus bars complete all as specified and directed. (Make: SHI, HPL, Havells/Shallab) .
MCCB 160 Amp capacity with sheet metal enclosure, MCCB ,4 Pole, 50Hz , Icu= 25 KA at 415 volts, with thermal magnetic release & Ics=100% Icu with adjustable over load setting (minimum 70% to 100%) complete all as directed. Make : Legrand/ Schiider/ L & T/ABB/Siemens.
MCCB 100 Amp capacity with sheet metal enclosure, MCCB ,4 Pole, 50Hz , Icu= 25 KA at 415 volts, with thermal magnetic release & Ics=100% Icu with adjustable over load setting (minimum 70% to 100%) complete all as directed. Make : Legrand/ Schiider/ L & T/ABB/Siemens.
Earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel wire 4mm dia as earth lead Earth plate to pole test point including 25mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 550mm thick cover in 1:2:4 TYPE B-1 reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009
Earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel Strip of size 25 x 4 mm as earth lead Earth plate to bldg test point including 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 550mm thick cover in 1:2:4 TYPE B-1 reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009
Steel tubular swaged pole 11 M long type 410-SP-55 complete with CI base plate . Finial taper plug, bolts, nuts and screws etc including necessary painting inside with black bitumen paint and out side with two coats of aluminum paint over one coat of red oxide Primer and numbering of poles and black & white striping up to 1.5 Mtr height, 300mm wide complete all as specified and directed (earth work, PCC and cross arms, bolts, nuts, washers shall be measured and paid separately)
Stay assembly complete comprising of 7/3.0 mm galvanized stay stranded wire of required length to pole with and including flat iron clamp bolt, nuts and washers etc. including galvanized 14mm dia 400mm long stay bow with 20mm dia 215 cm and long stay rod with threaded ends G.I. nuts and washers galvanized steel plate of size 300x300x 6mm thick , 2 Nos thimble, MS clamps made out of 50 x6 mm flat iron loop insulator 90mmx140mm dia hole, 25mm porcelain complete all as specified and shown in electrical plate No. 1 of SSr Part-I including the necessary excavation in post holes in any type of soil returning, filling, well ramming and disposal of surplus soil to a distance n.exc 50M for from the starting point, PCC ( 1:3:6) type C-2 using 40mm graded stone aggregate size 600x600x600mm complete all as specified and shown in electric plate No 1 of SSR Part I.
Steel tubular( swan nack ) swaged pole 09 mtr long type 410-SP-31 complete with CI base plate . Finial taper plug, bolts, nuts and screws etc including necessary excavation and earth work, in loose/soft soil of size 600 x 600 x 1900mm, PCC 1:3:6 type C-2 in foundation, PCC 1:2:4 type B-1 in plinth block/coping disposal of surplus soil up to 50 M, Painting inside with black bitumen paint and out side with two coats of aluminum paint over one coat of red oxide Primer and numbering of poles and black & white striping up to 1.5 Mtr height, 300mm wide complete. (All type of PCC work, Cross arms, bolts, nuts, washers shall be measured and paid separately in respective item)
Sheet moulding compound(SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of sreet lights mounted on ploe with the provisions of cable entry and exit Make Sintex/hensel cat part No KF8350/ Siemens/L&T product code NO GSJB-2817 of size 280mmX170mmX130mm all as directed by the Engineer-in-ChargeSupply and Fix sheet moulding compound(SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of sreet lights mounted on ploe with the provisions of cable entry and exit Make Sintex/hensel cat part No KF8350/ Siemens/L&T product code NO GSJB-2817 of size 280mmX170mmX130mm all as directed by the Engineer-in-Charge
Twin core aluminium conductor 4 sqmm PVC insulated , shetaed wire drawn in pole from juction box to street light and including provn of holes in existing pole wherever required complete all as specified and directed.
Street light timer switch using timer for automatic switching off/on street light based on LUX level of natural light , The sensor along with suitable power contactor MCB support terminal shall be housed in enclosure 4 pole made out of anti rust/ shock proof/ termite proof/ confirming to IP54 suitable for 5 KW load three phase( Contactor shell be used Make of ABB/BCH/Legrand) Make Timer Nature switch/ Havells /Legrand
LED security light with aluminium pressure die cast housing , high purity PC Fresnel diffuser with silicon gaskets for IP-65 protection, power consumption < 20W & luminaire lumen > 2500lm and system efficiency > 100lm/W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm, LED Make:- Nichia/ Cree/Osram, CRI>70, ambient temperature range 0-450C, THD<10%, colour temperature 5700K, surge protection in CM-3.5KV, 50000 burning hours as per L70 criteria, multistage constant current-constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard including GI pipe medium grade ISI mark of size 32mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamps as required to fix to wall all as specified and directed. Make:- Wipro Cat Part No. LR02-291-XXX-57-XX or equivalent of Phillips / Bajaj
Flood light IP-66 LED light fitting of capacity 110 watt, 240 volt single phase 50 Hz consisting of aluminium pressure die cast housing with high purity PC freshnel diffuser with glass silicon gaskets complete assembly with LED accessories toughened prewired upto terminal block confirming to IS 10322 part 5/sec 1 : 1967 with inbuilt integrated electronic LED driver voltage surge protection not less than 3 KV, 2/3stage isolated driver, the LED lumen output colour temperature consisting complaint to LM 11000 K stranded system lumens of LED luminaries high lumen out put minimum 130 lm/watts , with suitable bracket, clamp, nut bolt washer, porcelean connecter, twin core pvc insulated aluminium cable 4.0 Sqmm , sheathed from fitting to junction box. Make : Philips Cat pt No BVP192LED110CW HO NB FG GR PSU OF Phillips OR EQUIVALANT of Bajaj/Wipro/Jaguar
Cable jointing kit suitable for 16 sqmm to 35 sqmm 1100 Volts grade LT cable for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all specified and directed Make : 3M / M-seal/ Denson/Reychem
Cable jointing kit suitable for 50 sqmm to 95 sqmm 1100 Volts grade LT cable for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all specified and directed Make : 3M / M-seal/ Denson/Reychem
Cable jointing kit suitable for 120 sqmm to 240 sqmm 1100 Volts grade LT cable for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all specified and directed Make : 3M / M-seal/ Denson/Reychem
Cable jointing kit suitable for 400 sqmm 1100 Volts grade LT cable for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all specified and directed Make : 3M / M-seal/ Denson/Reychem
Auto transfer switch, four pole, AC-315 amps, 50 Amps, 415 volt with sheet steel enclosure as per Havells Cat Pt No IHFYCDE315 of Havells Make or equevalant to L&T/Legrand or as approved.
Compact low tension all aluminum bus duct 1500A, 415 V sandwich type 3 phase + 100% Neutral, duly enclosed in sheet steel enclosure made out of hot galvanized sheet steel along with connected fittings viz horizontal / vertical, elbows, end joints, end flanges, horizontal / vertical Tee joints, copper flexible etc (minimum 1.5 mm thick) epoxy powder coated with high resistance to chemical agents, rigid and robust, compact and corrosion less, bus duct enclosure shall be designed for very high mechanical, electrical and heat loss efficiency, Enclosure shall be with IP-65 protection for both indoors and outdoors suitable for power distribution, single / multiple bolted mono block junction contact assembly made with splice plates (fish plates) shall be used for installing successive feeders / elbows / flanges etc, provided with aluminum protective earth strip / flat of 50% cross sectional area of phase conductor, internally / externally throughout the length of enclosure and shall be effectively connected to the enclosure by riveting / bolting or any suitable means for specified earth continuity, provided with GI canopy not less than 2 mm thick for outdoor stretches complete all as per NEC : SP-30 : 2011, IS-8623, IEC-61439-6, IEC-60364-5-54, IEC-529 & latest relevant standards, all as specified and directed. Make :- LEGRAND / L&T / GE / SCHNEIDER /SIEMENS Note :-(i) Compact Bus Duct shall be fixed to top of gallery / roof / floor / duct / trench / walls with necessary micro concrete along with fasteners, fixing arrangement like cross arms, bracing, supports clamps etc, connections at end point shall be done using copper flexible & their cost is deemed to be included in the quoted rate.
Supply, installation, commissioning of HT 11 KV , 3-Phase outdoor gang operated air break switch(Isolator), ISI Marked, CPRI tested, factory assembled, mechanically operated , mounted on insulators and steel frame suitable for 2-Pole, Horizontal or Vertical mounting fixed type complete with nine numbers of porcelain insulators( Three post insulators per pole) with bottom MS channel of adequate dimensions and strength, self lubricating central bush bearing , copper contacts made of ETP grade high conductivity copper and spring loaded for adequate contact pressure, duly plated to improve resistance to corrosion, All MS plate and hardware to be duly hot dip galvanized, with tin plated copper wire of adequate cross sections , operating mechanism through an insulated operating mechanism worked from ground level and mechanical locking facility, Rated Voltage-12 KV, Rated Continuous current-200 Amps, 3 Ploe, Rated frequency-50Hz, Power frequency withstand voltage across the isolating distance-32KV, Power frequency withstand voltage to Earth-28KV, Lightning Voltage withstand test across isolating distance-85KV Peak, Lightning voltage withstand test across phase to earth-75 KV, Rated short time & Peak withstand current-20KA, complete all as specified.
Single pole , 9 KV, horn gap non linear meta oxide resistance surge lighteing arrester as per IS-3070 ( Part I)1985suitable for working voltage of 11 KV with rated system voltage of 12 KV, out door type, maximum continuos operating voltage not less than 7.65 KV (rms), nominal discharge current 10KA(peak), power frequency reference lot less than MCOV, max residual voltage for discharge current of 10 KA and 8/20 micro sec-current wave- 40 KVp, long duration discharge class-II( as per IEC), pressure relief class/current-A/40KA,28/75 KV insulation level, 29.9 KV switching residual discharge loltage, 100 KA9peak) and 25mm/KV minimum creaping distance of highest system voltagewith all fittings, complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled red & white with words "DANGER 11 KV"written in English, Hindi & local language, compulsory figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT of size 25x20 cm.
Cable route/path indicator made out of 40 x 40 x 4 mm angle iron, 1 mtr long and plate of size 100 x 150 x 6 mm welded only on one side end having embosed on plate as "cable HT/LT" including PCC of size 30 cm x 30 xm x 30 cm duly embedded the angle iron including excavation/earth work complete
Dismantling of LT UG cable any size/type complete all as directed and specified. Note: Serviceable cable will be be re-use under item No 8.75 in the same work and unserviceable cable will be given to contractor as schedule of credit
Dismantling of HT UG cable any size/type complete all as directed and specified. Note: Serviceable cable will be be re-use under item No 8.76 in the same work and unserviceable cable will be given to contractor as schedule of credit
Dismantling of Electric Panel any size/type for re-use complete all as directed and specified.
Dismantling of HT four pole structure complete all as directed and specified.
Erecting only Steel tubular swaged pole complete (poles retrieved from srl item No 8.70 after dismantling)with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-55 11 mtr long, all as specified and directed including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well raming and dispasal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing complete, embedded portion shall be painted with two coat of black bituminous paint all as specified.
Fire stand with bucket 10 Ltr (06 Nos of water filled, 4 Nos filled with sand) fire hook 2 Nos, 2 Nos CO2 extinguisher capacity 4.5 Kg each confirming to IS-15683 -2018 to be stored in high pressure steel body cylinder complete all as specified of make :-Minimax / Cease Fire / Safewise/ Newage.
S&F of stainless steel hollow section sign board as per site requirement for fixing as in sign board with all fitting and fixture at site for fixing of retro- reflective sheet complete all as specified and directed.
Glow sign board on retro reflective sheet with back ground of any colour as directed, self illuminated depicting single line schematic diagram of the installation for any other specified matter duly marked as directed by Engr in charge. Note :- The frame work made out of stainless steel of glow sign board shall be measured and paid separately under item No. 8.73 of BOQ
Laying only in trench/pipe/on wall and connection and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty 1100 volts grade with stranded aluminium conductor of size 10 sqmm to 120 sqmm 3.5 core complete all as specified and directed. Note :- Cable obtained from item No. 8.67 shall be reused under this item and necessary transportation and preparation by shall be deemed included in quoted rate
Description all as per item No 8.75 here-in-before but HT UG cable 120 sq mm 3 core complete all as specified and directed Note :- Cable obtained from item No.8.68 shall be reused under this item and necessary transportation and preparation by shall be deemed included in quoted rate
Fire retardant / extinguishing PVC based Elect insulated synthetic mat of 2.5 mm thick + 10% conforming to BIS : DOCNO ETD-02 (5231)P, meeting requirements of IS. 3043, IS :5216 (P+1,2&3), IS :8437 and IEC 479 Pub-1, JEC1111 & 61112, tested for break down strength, Tensile / Elongation Ageing properties, insulation resistance, effects of Acid, Alkaline, Diesel & Transformer oil, leakage current test, fire test etc having min width of 1000 mm + 20 mm, complete as specified suitable for users voltage upto 11 KV with HT trolley movement. Make :- Suntex Entor / Laxmi Rubber / Dura Rubber or Equivalent as approved.
Drilling suitable dia horizontal bore holes for insertion / laying of 100 mm / 150 mm bore HDPE pipe of any description below / under existing road surface floor at a level not less than 1 mtr etc with using mechanical or manual device as required at site including making good the disturbed surface to match the existing after laying pipes complete all as specified and directed.
SHARDA CONSTRUCTIONS
M/s Prem Associates
BRITE INDUSTRIES
R D Bansal
Bal Singh and Sons
Chauhan Associates
JAKSON LIMITED
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .