Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹38.9 L+₹12,445.41 (0.32%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹39.3 L+₹55,046.67 (1.42%)Rejected-Finance | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹39.4 L+₹65,922.50 (1.70%)Rejected-Finance C 223 MIANWALI COLONY GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | L4 | Rejected-Finance Rejected due to highest rate quoted | |
| 5 | L5₹40.0 L+₹1.3 L (3.29%)Rejected-Finance RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L5 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | PAWAN KUMAR L1 | Chaudhary Constructions L8 | M/S ujjwal associates L4 | M/S Rohit Enterprises L11 | M/S GEETANJALI ENTERPRISES L9 | MRITUNJYA ASSOCIATES L5 | innovision limited L6 | M R INTERIOR HUB L7 | P R Constructions L3 | Manisha Yadav L2 | ARE ESS ENGINEERING SERVICES L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down PVC (SWR) pipes of any description with fitting and making good to disterbed surfaces.
Notes : The Area includes in this items to working in shaft portion upto 6th storied building. | 190 | RM | 5 ₹950 Lowest | 7 ₹1,330 | 10 ₹1,900 | 15 ₹2,850 | 10 ₹1,900 | 22 ₹4,180 | 13 ₹2,470 | 8 ₹1,520 | 9 ₹1,710 | 5 ₹950 Lowest | 10 ₹1,900 |
| 2.00 | S&F 110mm bore PVC(SWR) pipes single socketed in any length pressure rating 4Kg/Sq cm medium Grade fixed to walls/floor with dash through nut and bolt at every 2mtr length including) including all fittings complete all as specified and directed by Engineer-in-charge.
Notes : The Area includes in this items to working in shaft portion upto 6th storied building. | 115 | RM | 250 ₹28,750 | 224 ₹25,760 | 180 ₹20,700 | 250 ₹28,750 | 320 ₹36,800 | 555 ₹63,825 | 170 ₹19,550 Lowest | 222 ₹25,530 | 189 ₹21,735 | 208 ₹23,920 | 300 ₹34,500 |
| 3.00 | S&F 75mm bore PVC(SWR) pipes single socketed Pressure rating @4Kg/Sq cm medium grade in any length with rubber ring joint, fixed to walls/floor including taking down eaves, gutters rain water pipes (any size or pattern) including all fittings complete all as specified and directed by Engineer-in-charge.
Notes : The Area includes in this items to working in shaft portion upto 6th storied building. | 75 | RM | 200 ₹15,000 | 224 ₹16,800 | 150 ₹11,250 | 180 ₹13,500 | 280 ₹21,000 | 333 ₹24,975 | 135 ₹10,125 Lowest | 200 ₹15,000 | 169 ₹12,675 | 198 ₹14,850 | 250 ₹18,750 |
| 4.00 | S&F 110mm bore PVC (SWR) bends any radius With access door complete all as specified and directed by Engineer-in-charge. | 15 | Each | 100 ₹1,500 | 224 ₹3,360 | 150 ₹2,250 | 200 ₹3,000 | 200 ₹3,000 | 444 ₹6,660 | 115 ₹1,725 | 210 ₹3,150 | 69 ₹1,035 Lowest | 209 ₹3,135 | 300 ₹4,500 |
| 5.00 | S&F PVC(SWR) single equal branch pieces 110 mm bore "T" type with oval access doors complete all as specified and as directed by Engineer-in-Charge. | 20 | Each | 100 ₹2,000 Lowest | 224 ₹4,480 | 150 ₹3,000 | 200 ₹4,000 | 200 ₹4,000 | 444 ₹8,880 | 350 ₹7,000 | 240 ₹4,800 | 199 ₹3,980 | 239 ₹4,780 | 300 ₹6,000 |
| 6.00 | S&F PVC(SWR) single equal branch pieces 110 mm bore "Y" equal or unequal with access door complete all as specified and as directed | 4 | Each | 100 ₹400 Lowest | 277 ₹1,108 | 150 ₹600 | 180 ₹720 | 300 ₹1,200 | 444 ₹1,776 | 475 ₹1,900 | 300 ₹1,200 | 199 ₹796 | 299 ₹1,196 | 300 ₹1,200 |
| 7.00 | S&F 75mm bore PVC (SWR) bends any radius With access door complete all as specified and as directed | 15 | Each | 80 ₹1,200 | 177 ₹2,655 | 100 ₹1,500 | 160 ₹2,400 | 150 ₹2,250 | 222 ₹3,330 | 95 ₹1,425 | 200 ₹3,000 | 59 ₹885 Lowest | 165 ₹2,475 | 250 ₹3,750 |
| 8.00 | S&F PVC(SWR) single equal branch pieces 75 mm bore "T" type with oval access doors complete all as specified and as directed by Engineer-in-Charge. | 15 | Each | 80 ₹1,200 Lowest | 177 ₹2,655 | 100 ₹1,500 | 140 ₹2,100 | 150 ₹2,250 | 222 ₹3,330 | 350 ₹5,250 | 200 ₹3,000 | 169 ₹2,535 | 199 ₹2,985 | 250 ₹3,750 |
| 9.00 | S&F 75mm bore( SWR) vent cowl complete all as specified and as directed | 14 | Each | 100 ₹1,400 | 77 ₹1,078 | 100 ₹1,400 | 40 ₹560 Lowest | 80 ₹1,120 | 222 ₹3,108 | 80 ₹1,120 | 100 ₹1,400 | 49 ₹686 | 99 ₹1,386 | 250 ₹3,500 |
| 10.00 | Taking up or down Steel Tubing 15mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Notes : The Area includes in this items to working in shaft portion upto 6th storied building. | 125 | RM | 10 ₹1,250 | 7 ₹875 | 2 ₹250 Lowest | 15 ₹1,875 | 10 ₹1,250 | 44 ₹5,500 | 90 ₹11,250 | 5 ₹625 | 5 ₹625 | 4 ₹500 | 10 ₹1,250 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
17 Jul 2025, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
CERTAIN REPAIRS TO SUNKEN PORTIONS FLOORING PLASTERING JOINERY SANITARY FITTINGS PERIODICAL AND INTERNAL WATER SUPPLY INCL MISC REPAIR WORKS TO BLDG IN BLOCK NO FROM 1 TO 14 AT TEJAS ENCLAVE AT AFSSR GURGAON UNDER GE (AF) GURGAON
2025_MES_716988_1
GE/GUR-/NIT-42/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹88,000
21 Aug 2025
26 Jun 2025
19 Jul 2025
26 Jun 2025
17 Jul 2025
10 Jul 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .