Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹34.8 Cr
EMD Value
₹44.8 L
Closing Date
7 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer, BUILDING DIVISION NAWADA
EE
Executive Engineer , Building Division Nawada, BCD, BIHAR
Superintending Engineer, BUILDING CIRCLE GAYA
SE
CONSTRUCTION OF 10 COURT BUILDING(G+5) ,AMINITY BUILDING (G+4) ,HAZAT BUILDING (G+1) IN SUBDIVISIONAL COURT CAMPUS AT RAJAULI ,NAWADA
144131
NIT 06/BCD/NAWADA/2026-27
Open Tender
CIVIL
Nawada
• Bid Security Amount in Rupees (A) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1
Total Bid Security Amount in Rupees 4475400.00
IFB
• (i) Legal Status of Bidder 4.3(a)
(ii) Place of Registration.
(iii) write Principal place of Business.
(iv) Power of attorney of signatory Bid 4.2(iv)
• Total value of civil engineering construction work, in Rupees, Performed in last five years.
Minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work ,which must be at least equal to 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year
2021-2022
2022-2023
2023-2024
2024-2025
2025-2026
• Amout in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost
4.5(A) (b)
• 4.5A( c) (c) Executed in any one year, the minimum quantities /amount of the following items of work (units shall be same as in Requirement column).
SI No Item Unit 50%
1 Earth work CUM 3871.935
2 P.C.C CUM 685.69
3 R.C.C CUM 3246.725
4 BRICK WORK CUM 1565.57
5 TILES/KOTA/GRANITE SQM 5617.465
6 REINFORCEMENT KG 423185.5
7 MS GRILL (MILD STEEL) kG 21497.5
8 SS WORK (Stainless steel work) kG 2968.15
9 FIRE FIGHTING RS 4032747.5
10 FURNITURE RS 14858669
11 P.H.E/SANITARY RS 2802342.5
12 ELECTRICAL WORK RS 17095583.5
• (a) Amount of Existing commitments and ongoing works in Rupees Sec 2-1.4(A)
(b) Amount of Work for which Bid already submitted, in Rupees Sec 2-1.4(B)
• Numbers and Maximum age of Equipments with bidder
Type of Equipment Nos. Maxm. Age Sec 2-1.5
Concrete Batching & Mixing plant Minimum capacity 15m3/hr . 5 1
Pump for concreting 5 1
Transit Mixture 5 1
Vibrator (Plate & Niddle) 5 5
Water Tanker 5 2
Steel shuttering 5 10000sft
• Name of the Personnel and Experince in years and Personnel / Qualification 4.5(B) (b)
Personnel / Qualification
Project Manager B.E. Civil + 10 Years Exp. (5 years as Manager having MBA) or equivalent or retired E.E. 1 No.
Site Engineer B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 2No
Plant Engineer B.E. Mech./ Civil + 03 Years Exp. or Dip. Mech + 05 Years Exp. or Retired J.E. 1 No.
Quantity Surveyor B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp. 1 No.
Site Supervisor Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 3 Nos.
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (for work under this bid). 4.2(i)
Proposed methodology and programme of construction Select from drop down list the proposed methodology and programme of construction, backed with equipment planning and deployment 4.3(l)
• Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
• Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct. Sec-2, Affidavit
Undertaking Select from drop down list. Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
Registration No.
IT.& ST Registration & clearance Certificate
Labour License
Character Certificate
NOC for Debar (If required)
CIVIL
PERCENTAGE
L1
1
14 documents required · 14 mandatory
₹10,000
Processing Fee: 11800
₹44.8 L
19-11-2026 03:00 pm AT OFFICE OF SE GAYA CIRCLE , BCD, GAYA
23 Nov 2026
23 Nov 2026
8 Dec 2026
23 Nov 2026
7 Dec 2026
23 Nov 2026
120 days
Amenity
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Eartg work in excavation
Extra for every additional lift of 1.5m or part thereof in:
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurement to be taken of the face area timbered):
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
1:2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.cum 1Cement: 3coarse sand:6 graded stone aggregate 20 mm nominal size)
Extra for providing and mixing water prooding material in cement concrete work in the proportion recommended by the manufacturers.
Foundations, footings, bases of columns, etc., for mass concrete.
Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cost in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Stairs, (excluding landings) except spiral staircases.
Arches,domes,vaults upto 6m span
Metre
Wheather shade, Chajja, corbels etc., including edges.
Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia.
TMT -500-16 mm dia.
TMT -500-20 mm dia.
TMT -500-25 mm dia.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength andadmixtures in recommended proportions as per IS: 9103 to accelerate,reinforcement,durability as per direction of Engineer-incharge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.
All work upto plinth level
All work from plinth level upto floor V level.
Providingand laying inpositionmachinebatched,machinemixedand machine vibrateddesignmix cement concrete of specified grade for reinforced cement concretestructural elements, excluding thecost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete
pro and laying in position M20 all work up to plinth level
wall ,column ,pillar ,post
beam ,plinth beam roofs,lintel etc
Providing and laying in position specified grade of reinforced cementconcrete excluding the cost of centring,shuttering,finishing andreinforcement-All work puto plinth level
Brick work with bricks with fly ash bricks as per IS 12894(2002) & 3495 in foundation and plinth in :
cement mortar 1:4 (1 cement : 4 coarse sand)
cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with Cement mortar 1:6 (1 cement: 6 coarse sand )
Extra for Brick work in superstructure above plinth level upto floor V level
brick work with 100A cm 1:4
brick work with 100A cm 1:4in s/s
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high loss finish etc. complete at all levels.
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including rubbing,moulding and polishing of cut edges etc. complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
Extra for providing lipping with 2nd class wood battens 25 mm minimum depth on all edges of shutters (Over all area of door shutter to be measured).
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately).
Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In• Charge. {Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete
Providing and fixing aluminium sliding door bolt anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc.
Providing and fixing aluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc.
Providing and fixing aluminium handles anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge.
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer in-charge
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-incharge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc.,with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-charge.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on backside of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge,all complete.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing 1 mm thick M.S.sheet sliding - shutters with frame and diagonal braces of 40x40x6 mm angle iron,3 mm M.S. gusset plates at the junction and corners, 25 mm dia pulley, 40x40x6 mm angle and T-iron guide at the top bottem respectively including applying a priming coat of approved steel primer.
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer.
Providing and fixing steel glazed doors, windows and ventilators of standard rolled steel sections, joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6(1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal-sash putty of approved make complete including applying a priming coat of approved steel primer; excluding the cost of metal beading and other fitting except necessary hinges or pivots as required.
Providing and fixing pressed steel door frame confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge.
Metre
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
steel work in welded and builtup section
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Extra for providing and fixing steel beading of approved shape and section with screws instread of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.
Providing designation FLY ASH brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting (upto 30 cm hieght) with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1 st quality conforming to IS : 13755 of NITCO , ORIENT , SOMANY , KAJARIA or equivalent make in colours such as white , Ivory , Grey , Fume , Red , Brown , laid on 20 mm thick cement motar 1:4 (1 cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments etc, complete.
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with
Providing and fixing 10 mm thick acid and / or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and / or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand
Kota stone slabs 20 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Details of cost for 10 sqm
Providing& fixing inpositionPhenol bondedBamboowood flooring with planks of sizes 14mm thick, minimum 1800mm length and minimum100mmwide, inapprovedcolour, textureandfinish,having PerformanceAppraisalCertificate(PAC) issuedbyBuildingMaterials&
12 mm cement plaster of mix
1:6 (1 cement : 6 coarse sand)
cement plaster 12mm thick with cm 1:4
15 mm cement plaster on rough side of single or half brick wall of mix.
6 mm cement plaster to ceiling of mix.
15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall
Extra for plastering exterior walls of height more than 10m form ground level for every additional height of 3 m or part there of
Finishing walls with Acrylic Smooth exterior paint of required shade
Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade .New work (two or more coats ) over and including priming coat with cement primer
cement paint with primer over new work
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: New steel work (two or more coats) With ready mixed zinc chromate yellow primer of approvedbrand and manufacture on steel alvanized iron/steelworks
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.
Forming groove of uniform size from 12x12 mm and upto 25x15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
Neat cement punning
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement
15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of :
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/ sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5 cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
Providing and laying integral cement based water proofing treatment including prepatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water froofing compound conforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test, All above operations to be done in order and as directed and specifed by the Engineer-in-Charge
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
Brick work 7cm thick with brick of class designation 100A cement mortar 1:3 (1 cement: 3 coarse sand) in super structure
Grading roof for water proofing treatment with
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063)
Metre
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-
Metre
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self-centering arrangement that freely rotates / moves in all directions.The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding
Metre
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent(including the cost of chemical emulsion)
With chlorpyriphos/Lindone E.C. 20% with 1% concentration
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.55 litres per linear metre including drilling and plugging holes etc.
Metre
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor
Supplying and fixing C.I. cover without frame for manholes :
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
Providing and fixing soil, waste and vent pipes :
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing and fixing wooden Dais all complete as per building specification and direction of E/I.
Providing and fixing wooden Wall panelling all complete as per building specification and direction of E/I.
Providing and fixing wooden apperance box with fencing (Size 2.10 Long x 1.50 Wide x 1.05 Mtr Hight) all complete as per building specification and direction of E/I.
Providing and fixing wooden witness box with fencing (Size 1.20 Long x 1.20 Wide x 1.05 Mtr Hight) all complete as per building specification and direction of E/I.
Per 1000 Nos.
Amenity
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete.
Providing and fixing white vitreous china water closet squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, 10 litre low level PVC flushing cistern (of approved make) with fittings CI/MS brackets, 32 mm diameter flush pipe with fittings and clamps, over flow arrangement with specials and mosquito proof coupling of approved municipal design including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including ntegrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass lush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms.
Providing and fixing white vitreous china wash basin with C.I. / M.S. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
32 mm dia
40 mm dia
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required :
Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete.
Providing and fixing 600 x 120 x 5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc. complete
Providing and fixing toilet paper holder:
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for therma expansion.(SW)
Coupler
Single tee with door
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC pipes,having thermal stability for hot & cold water supply,
metre
metre
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
15mm nominal outer dia pipes
20mm nominal outer dia pipes
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
32mm dia nominal bore
40mm dia nominal bore
Providing and fixing brass stop cock of approved quality :
15 mm dia
20 mm dia
Making connection of G.I distribution branch with G.I main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.
Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end).
20 mm nominal bore
32 mm nominal bore
40 mm nominal bore
Providing and fixing gun metal non-return valve of approved quality (screwed end).
PVC water tank
15 mm nominal bore
Providing and fixing PTMT grating of approved quality and colour.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy aluminium rod with L.P / H.P.H.D plastic ball.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931
Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
Cutting holes up to 30 x 30 cm in walls including making good the same:
Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof.
Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba.
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal\ size) as per standard design
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS : 2800 (part I), including collecting samples form different strata, preparing and submitting strata chart / bore log, including hire & running Charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 90 metre depth below ground level, all type of soil.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS : 4097, including providing gravel fine / medium / coarse , in required grading & sizes as per actual requirement , all complete as per direction of Engineer - in-Charges.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I ) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by 'V' notch method or any approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threated mild steel cap or spot welded plate to the top of bore well housing / Casting pipe, removable as per requirement, all complete for borewell of :
Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tube well as per IS : 2800 (part I ), including necessary bots & nuts of required size complete.
Providing and fixing Ball plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (Part I)
S/F/F 2 H.P. Cromption or any other apprioved ISI Mark
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc.And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil.
Metre
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
metre
Providing, laying Non pressure NP2 class (light duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete.
Metre
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design
Metre
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
With F.P.S. bricks (For Storm water)
With F.P.S. bricks (For Sewer)
Extra for depth for manholes
F.P.S. bricks (For Storm water)
F.P.S. bricks (For Sewer)
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design
Brick drain
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer- incharge.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete
Providingandlayingatorneargroundlevel factorymadekerbstone ofM-25gradecementconcreteinpositiontotherequiredline, level andcurvature, jointedwithcementmortar1:3(1cement: 3coarse sand), includingmaking jointswithorwithoutgrooves(thicknessof jointsexceptatsharpcurveshallnot tomorethan5mm), including makingdrainageopeningwherever requiredcompleteetc. asper directionofEngineer-in-charge(lengthof finishedkerbedgingshall bemeasured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of/and manure before and after flooding trench with water (including cost of imported earth,sludge or manure).
Supplying and stacking of good earth at site including royalty but excluding carriage (earth measusred in stacks will be reduced by 20% for payment).
Supplying and stacking Sludge at site including royalty and carriage (Sludge measusred in stacks will be reduced by 8% for payment)
Supplying and stacking a' site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment). Screened through sieve of l.S. designation 4.75 mm
Rough dressing the trenched ground including breaking clods.
Uprooting weeds form the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing the ground
Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately).
Mixing earth and sjudge or manure in porportion specified or directed.
Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more tili the grass forms a thick lawn free form weeds and fit for mowing including supplying good earth if needed. In rows 5 cm apart in either direction.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m dia. And 1.2 m deep.
Holes 60 cm dia And 60 cm deep
Providing, stacking and Displaying Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot / Plastic pot and as per direction of the officer-in-charge.
Providing, stacking and Displaying Ficus Starlight with fresh, healthy and attractive foliage 45 cm to 60 cm spread 75 to 90 cm ht. plant, specimen bushy plant,in 35 cm Cement Pot/ Plastic Pot and as per direction of the officer-in-charge.
Providing and stacking of Polyalthia longifolia (Ashok) height 180-195 cm. in gunny bag size 30 cm as per direction of the officer-in-charge
Supply, installation, testing and commissioning of Electric motor driven main fire pump set suitable for automatic operation of hydrant complete in all respect consisting of following as per specifications .
a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable forautomatic operation and consisting of following,complete in all respects, as required : (Diesel DrivePump)Horizontal type,multistage, centrifugal pumpof cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Supply, Installation, testing and commissioning of electric driven pressurisation (Jockey) pump set suitable for automatic operation and consisting of following: complete in all respect as required .
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (Make: Kriloskar / KSB)
Supplying, installation, testing and commissioning ofelectric driven terrace pump suitable for automaticoperation and consisting of following, complete in all respects, as required: (Terrace Pump
Supply, Installation, Testing & Commissioning of cubicle type panel made out of 2mm thick CRCA sheet, totally enclosed, IP 42, floor mounted with channel base frame, dust and vermin proof, indoor, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including control wiring with 2.5 sq mm size FRLS wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories as per specifications . (Make :- National / S.D. Fire)
Fabrication, supply, Insallation testing&commissioning of Electrical control panelof cubical construction, floormounted type, fabricated out of 2mm thick CRCAsheet, compartmentalised with hinged lockable doors,dust and vermin proof, powder coated of approved shadeafter7tanktreatmentprocess,cablealley, interconnectionwith suitable size copper conductorcable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earthterminals, numbering etc. complete in all respect,suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specificationwith following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
Supply, Installation, testing and commissioning of pressure switches with isolation ball valve for Hydrant / Electric Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-10 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications.
Suppling and fixing 150mm dia way fire brigade connection of cast iron body with 3 nos SS male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required as per specifications. (Make : Kalpex, Safe Fire, Kartar, Newage, S.D. Fire)
Supply, installation, testing and commissioning of mild steel pipe (IS : 1239 Part-1) heavy class including cutting, threading, welding etc. bends, elbows, reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including the cost of structural work for supports fabricated from standard sections of required sizes and thickness e.g. MS rods, angles channels, slotted angle, etc. cutting to sizes, drilling welding fixing to insert plates, including painting with one coat of primer and two or more coats of synthetic enamel paint of approvedd make and shade including all steel work. Note: Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints. (Make : Nezone/Tata/Jindal)
25 mm dia
50 mm dia
65 mm dia
100 mm dia
150 mm dia
200 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneousGunmetal/StainlessSteel couplingof 63mmdiawith cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Supply, fixing, testing and commissioning of Slim seal butterfly valves B 190 class (PN 1.6) complete with matching flanges, inserion, nuts, bolts and washer etc. of following sizes. (Make : AIP / L.P. / Surya)
Supplying and fixing single headed, stainless steel ISI marked oblique pattern hydrant landing valve with 80mm dia flanged outlet complete with ABS blank cap and chain, twist release type plug and all accessories as per IS : 5290-1983 (Type-'A'). (Make : Safeguard, Kalpex, Safe Fire, S.D. Fire)
Supplyingandfixingorificeplatemadeoutof6mmthickstainlesssteel (Grade304)withorificeof requiredsizetobefittedbetweenflange& landingvalveof external and internal hydrants toreducepressureat the outlet to the level of 3.5 kg/cm2 complete as required
Providing and fixing cast iron double flanged wafer type Non- return valve PN 1.6 of approved quality conforming to IS:5312 with C.I. wheel, bolts, nuts, washers, 3 mm thick inserion rubber gaskets complete. (Make : AIP / L.P. / Surya)
Providing and placing in proper position stainless steel 63mm dia short size branch pipes with 20mm dia nozzles wfith 63mm instantaneous coupling ISI marked (IS : 903). (Make : Safeguard, Kalpex, Safe Fire, S.D. Fire)
Providing and placing in proper position Non-percolating flexible hose (RRl type-'A' ISI marked (IS: 636) 63mm dia x 15m long complete with instantaneous type stainless steel 63mm dia. IS marked male and female coupings (IS : 903). (Make : Safeguard, Kalpex, Safe Fire, S.D. Fire)
Supplying, fixing, testing&commissioning of double flangedsluice valveof ratingPN1.6withnonrisingspindle,bronze/gunmetal seat, ISImarkedcompletewithnuts,bolts,washers,gasketsandconforming to IS 780 of following sizes as required
Providing , fixing, testing and commissioning of First Aid Fire Hose Reel wall mounting , swinging type complete with drum, bracket, stop valve 20 m dia. 30M long hosereel tubing with shutoof nozzle conforming to IS:8090-1976 with 5mm orifice, Mollimax, on Guard, S.D. Fire
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories
Supplyingandfixingairvesselmadeof250mmdia,8mmthickMS sheet, 1200mminheightwithair releasevalveon topand flanged connectiontoriser,drainarrangementwith25mmdiagunmetalwheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
Providing, fixing, testing&commissioningof installationcontrolvalve ofcast ironbody,brass/bronzeworkingpartscomprisingofwatermotor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarmwhen the wet riser/sprinkler system activates, pressure gauges, emergency releases,strainer,pressureswitch,cockvalvecompletewithdrainvalve andbypass, test control box, ball valves,MSpipeof required size, flanges, orifice plate, gasket etc of follwing sizes as required
Supplying,installation,testing&commissioningofsprinkler flexiblepipe (ULListed)ofstainlesssteelcompletewith15NPTonreducer thread withmaximumworkingpressureof175PSI testpressureof 875PSI (Burst)withbranchline(Inlet)25mmNPTmalethreadtosprinklerhead (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete as required
Supply, Installation , Testing and commisoning Cable 2 x 1.5 mm dia as per necessary fitting. Make :- LNT/ Polycab/ Anchor / National
Supply, installation, testing & commissioning of Smoke Detector & Fire AU Two Loop Control Panel with LCD display, battery backup facility, complete in all respect.
Supply, installation, testing & commissioning of Addressable Smoke Detector with base, complete in aI1 respect.
Supply, installation, testing & commissioning of Addressable Manual Call Point (MCP), complete in all respect.
Supply, installation, testing & commissioning of Fire Alarm / Horn cutn iitrobe, complete in all respect.
Supplying a d fixing of Single door Hose Box, 18 SWG M.S. body with hin ed lockable do rs, suitable for accommodate 1 No. RgL Hose and 1 No. Sort Branch Pipe Size : 20 mm x 20 mm x 10 mm)
Providing & fixing of ABC Powder type (Stored Pressure) Firt Extingtiishet 6 Kg. Capacity,. III Mark (IS:15683), Glled with MAP Powder, Complete in !all respect..
Providing & Jixing of Carbon Dloxlde (CO2) type fire extinguisher 4.5 Kg. Capacity, ISI Mk (IS:15683), fitted with 1 Mtr. Hose & PVC Horn, Complete
Providing & fixing of Autoglow Photoluaiinscent Signages (Eco Sheet) of illumination of Emergency EXIT / Fire Exit Signs that marks the life savtng Exit/Way Finding paths for Emergency Evacuation, General Safety and Caution Warning(Size: 100 mm x 300 mm)
Providing and fixing ISI marked Life Guard ABC type multipurpose Fire Extinguishers 4 Kg. Capacity, fitted with pressure guage complete in all respects, ready to use, complete installation kit. (Make : Ceasefire, Kalpex, Safe Fire, S.D. Fire)
Providing and fixing ISI marked Life Guard Water type multipurpose Fire Extinguishers 9 Lt. Capacity, fitted with pressure guage complete in all respects, ready to use, complete installation kit. (Make : Safepro, Fire Tips, S.D. Fire)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Supplying and fixing 2 pin, 6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing 4'X20 watt LED batten with minimum efficacy 100 lm/w in aluminium housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. (For Non-residential building)
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types aluminium extruded suspended type LED luminaire with minimum efficacy 100 lm/w ensuring uniform and continuous illumination including suspension system complete with electronic driver etc and connection with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supply, Instaiiation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 1eiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required.
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd.
Supply of Pilot lamp for indicator
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Metre
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supplying and fixing following types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Meter
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.(for Ground to Each Floor Panel)
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Meter
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Meter
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD).Lift with power operated centre opening door and AC variable voltage &variable frequency control. All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Metre
Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required
Supply and Fixing Modular type 2 Pin Telephone Socket for Speaker Outlet on the existing modular plate & box including making connection, excluding modular plate etc as required
Supplying and Drawing 2 pair 0.5 sq mm. FR PVC insulated copper conductor telephone cable through existing PVC concult including connection etc as required.
Supplying, Installation, Testing Commissiong of MATRIX Digital ISDN Switching System Eternity - GENX 12S AC (MATRIX Make) Equipped for: 2 P&T Lines, 2 Digital Port & 56 Analog Extension, Expandable up to 240 Lines
Supply, installation, testing and commissioning of Digital Phone
Supply, installation, testing and commissioning of telephone instrument.
Supply, Installation, Testing & Commissioning of 100 Pair Distribution Tag Box all Component as per specification.
Supply installation testing & commissioning of 20 Pair Distribution Tag Box all Component as per specification.
Supplying and drawing 20 pair 0.5 sq mm. FR PVC insulated copper conductor
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Metre
Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell )
Supplying, Installation, Testing & Commisioning of 2 Mtrs long factory made CAT 6U/UTP RJ 45 patch cord ( Make - Legrand/D-Link/Molex )
Supplying, Installation, Testing & Commisioning of 1 Mtrs long factory made CAT 6U/UTP RJ 45 patch cord ( Make - Legrand/D-Link/Molex )
Supplying fitting fixing 6U Network Rack CRCA 'D' Grade thickness (mm) 1.2, RAL 9017 (Matt Black). Glass - 4mm Toughened Tinted Glass Door, Accessories:, Cooling Fan (230V A/C 90 CFM)-2 Nos, PDU 230VAC - 1 No. Cable Manager Metai. 1 No, Mounting Hardware (20 sets of M6 screws,washer,cage nuts (nickel coated)) 1 No, Wall Screws (4 sets of 2" screws,washer,rubber grommet (nickel coated)) 1 No, Door Lock 1 No. Front Metal Band -1 No. In the rack there must be maintained 1 U = 1.75 inches space. complete etc as required. (Make - Legrand/ Netrack/ Rittal)
Supplying fitting fixing 12U Network Rack CRCA 'D' Grade thickness (mm) 1.2, RAL 9017 (Matt Black). Glass - 4mm Toughened Tinted Glass Door, Accessories:, Cooling Fan (230V A/C 90 CFM)-2 Nos, PDU 230VAC - 1 No. Cable Manager Metai. 1 No, Mounting Hardware (20 sets of M6 screws,washer,cage nuts (nickel coated)) 1 No, Wall Screws (4 sets of 2" screws,washer,rubber grommet (nickel coated)) 1 No, Door Lock 1 No. Front Metal Band -1 No. In the rack there must be maintained 1 U = 1.75 inches space. complete etc as required. (Make - Legrand/ Netrack/ Rittal)
Supplying Fitting fixing Cat6 U/UTP 24 Port 19" Modular Type Paech Panel Loded with 24x Toolless RJ 45 which is 6 in a block complete etc as required. ( Make - Legrand/D-Link )
Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP)
Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link)
Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
Point
Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. )
Supply, installation, testing and commissioning of Silent Type diesel generating set comprising with diesel engine water cooled, synchronous alternator, AMF Control Panel single/three phase, acoustic enclosure, battery with charger and related accessories, including PCC 1:2:4 platform, incoming cable 10 meter, earthing Cu/GI Plate 2 No /2 No., exhaust pipe B class with insulation as per CPWD specifications and CPCB-IV Norms
Providingang and laying in position reinforced cement concrete 1 : 2 : 4 (1 : cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size ) in foundation of pump, DG set etc including form work etc. as required. (excluding reinforcement) for Genset , Plinth) 3.2 m X 5.2 m = 15 cum)
Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local language duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
Wiring for light point/fan point /exhaust fan point/call bell point with 1.5sq mm FR PVC insulated copper conductor S/C cable in surface/recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I box etc. as required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Wiring for circuit/submain wiring along with earth wire with the following size of FR PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recessed, complete with tinned copper busbar, neutral busbar, earthbar, dinbar, interconnections, powder-painted including earthing etc as required.(But without MCB/RCCB/Isolator)
S/F following rating, double pole, 240 volts, isolator in the existing MCB DB omplete with connections testing and commissioning etc as required.
S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
Supplying and fixing 2 pin, 6 amps ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
Supply, Instaiiation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 1eiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number pvc insulated and pvc sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refiling the trench etc. as reqd.
Earthing with G.I earth pipe 4.5 mtr. Long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal /coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying & fixing 40/45 watt LED type flood light with die cast 0 aluminium housing for ingress protection of IP65 and complete with all accessories etc. and connection with FR pvc insulated copper conductor cable and earthing the body etc. As reqd.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/foundation (during casting )for cable entry including bending the pipe to the required shape complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire ondition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local language duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
Wiring for light point/fan point /exhaust fan point/call bell point with 1.5sq mm FR PVC insulated copper conductor S/C cable in surface/recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I box etc. as required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Wiring for circuit/submain wiring along with earth wire with the following size of FR PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
Meter
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required .(but without MCB/RCCB/Isolator)
supplying and fixing four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing commissioning etc. As reqd.
S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. As reqd.
P/F following capacity 4 pole on load/panel mounted changeover switches inside the existing cubical pannel board including drilling holes in cubical panel, making connections etc as required.
S/F 50 mm x 5mm copper strip (2.30 kg /mtr) for busbar as required.
Supply of Pilot lamp for indicator
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Metre
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supply, Instaiiation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 1eiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/ w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/ building including connection earthing the body etc as required. (120 watt)
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/foundation (during casting )for cable entry including bending the pipe to the required shape complete as required.
Supplying and fixing of light class G.I. Pipe of 80 mm dia. (nominal) 3 meters length along with pole for protection of under ground cable as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 m long etc. with charcoal /coke and salt as required.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, installation, testing and commissioning of Silent Type diesel generating set comprising with diesel engine water cooled, synchronous alternator, AMF Control Panel single/three phase, acoustic enclosure, battery with charger and related accessories, including PCC 1:2:4 platform, incoming cable 10 meter, earthing Cu/GI Plate 2 No /2 No., exhaust pipe B class with insulation as per CPWD specifications and CPCB-IV Norms
62.5 KVA, 3 Phase 415V Water Cooled with AMF Control Panel Make - Kirlosker/Ashok Layland/ Captiva/Catepiller
Providingang and laying in position reinforced cement concrete 1 : 2 : 4 (1 : cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size ) in foundation of pump, DG set etc including form work etc. as required. (excluding reinforcement) for Genset , Plinth) 3.2 m X 5.2 m = 15 cum)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Meter
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Meter
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD).Lift with power operated centre opening door and AC variable voltage &variable frequency control. All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements
Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
Supply, Installation, Testing and Commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supply, Installation, Testing and Commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supply, Installation, Testing and Commissioning of response indicator on surface/ recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supply, Installation, Testing and Commissioning of intelligent addressable programmable sounder complete as required.
Supply, Installation, Testing and Commissioning of fault isolator complete with base as required.
Supply, Installation, Testing and Commissioning of addressable fire control module complete as required.
Supply, Installation, Testing and Commissioning of addressable manual call point complete as required.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local language duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Metre
Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required
Supply and Fixing Modular type 2 Pin Telephone Socket for Speaker Outlet on the existing modular plate & box including making connection, excluding modular plate etc as required
Supplying and Drawing 2 pair 0.5 sq mm. FR PVC insulated copper conductor telephone cable through existing PVC concult including connection etc as required.
Supplying, Installation, Testing Commissiong of MATRIX Digital ISDN Switching System Eternity - GENX 12S AC (MATRIX Make) Equipped for: 2 P&T Lines, 2 Digital Port & 56 Analog Extension, Expandable up to 240 Lines
Supply, installation, testing and commissioning of Digital Phone
Supply, installation, testing and commissioning of telephone instrument.
Supply, Installation, Testing & Commissioning of 100 Pair Distribution Tag Box all Component as per specification.
Supply installation testing & commissioning of 20 Pair Distribution Tag Box all Component as per specification.
Supplying and drawing 20 pair 0.5 sq mm. FR PVC insulated copper conductor
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Metre
Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell )
Supplying, Installation, Testing & Commisioning of 2 Mtrs long factory made CAT 6U/UTP RJ 45 patch cord ( Make - Legrand/D-Link/Molex )
Supplying, Installation, Testing & Commisioning of 1 Mtrs long factory made CAT 6U/UTP RJ 45 patch cord ( Make - Legrand/D-Link/Molex )
Supplying fitting fixing 6U Network Rack CRCA 'D' Grade thickness (mm) 1.2, RAL 9017 (Matt Black). Glass - 4mm Toughened Tinted Glass Door, Accessories:, Cooling Fan (230V A/C 90 CFM)-2 Nos, PDU 230VAC - 1 No. Cable Manager Metai. 1 No, Mounting Hardware (20 sets of M6 screws,washer,cage nuts (nickel coated)) 1 No, Wall Screws (4 sets of 2" screws,washer,rubber grommet (nickel coated)) 1 No, Door Lock 1 No. Front Metal Band -1 No. In the rack there must be maintained 1 U = 1.75 inches space. complete etc as required. (Make - Legrand/ Netrack/ Rittal)
Supplying Fitting fixing Cat6 U/UTP 24 Port 19" Modular Type Paech Panel Loded with 24x Toolless RJ 45 which is 6 in a block complete etc as required. ( Make - Legrand/D-Link )
Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP)
Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link)
Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
Point
Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. )
Supply and erection of 4 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Meter
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Meter
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering.
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required.
Supplying and fixing post top / gate light (width 250/300 mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( But without lamp)
12 watt LED lamp
Meter
Meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT 06_AND Papercutting.pdf
NIT • 1.14 MB
CHECK LIST AND OTHER DOCUMENTS.pdf
NIT • 14.19 MB
Joint Venture Guidelines.pdf
NIT • 1.20 MB
NIT 6_SBD.doc
NIT • 0.87 MB
BOQ 10 COURT.xlsx
NIT • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .