| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.7 L+₹2.4 L (9.71%)Rejected-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.4 L+₹4.0 L (16.5%)Rejected-AOC NOT AVAILABLE | L3 | Rejected-AOC L3 | |
| 4 | L4₹29.3 L+₹5.0 L (20.5%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
1 Apr 2021, 6:00 pmClosed
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati 15 Assam Pin 781015
CONSTRUCTION OF STORAGE SHED OF GE AF BORJHAR
2021_MES_427932_1
CWE (AF)/BOR/TOKEN-56 OF 2020-21
Open Tender
Construction Works
Item Rate
180 days
Borjhar
As per Tender documents
8 documents required · 8 mandatory
₹500
GE AF Borjhar
₹70,000
Yes
5 May 2021
4 Mar 2021
3 Apr 2021
4 Mar 2021
1 Apr 2021
18 Mar 2021
Amount
SCHEDULE A PART-I Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth for foundation etc or for shafts, wells, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in in soft/loose soil complete all as specified and directed
Description all as per Item No 1 above but depth beyond 1.5m and n.exc. 3.00m complete all as specified and directed
PCC (1:4:8) type D-2 (using 40mm graded stone aggregates) as in foundations, fillings and mass concrete complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, sides and soffits of foundation and plinth beams, and similar works, verticle or to batter for rough finished surfaces of concrete complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, for rough finished surfaces of concrete complete all as specified and as directed.
RCC (1:1.5:3) type A -1 (using 20mm graded crushed stone aggregates) as in foundations including rafts, foundation beams, plinth beams, bases for columns, etc, and mass concrete complete all as specified and as directed.
RCC (1:1.5:3) type A -1 (using 20mm graded crushed stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Description all as per Item No 8 above but 5 mm dia and over upto 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Hardcore of broken stone or boulders of gauge n exc. 63mm, deposited, spred and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
75mm thick PCC (1:4:8) type D2 using 40mm graded crushed stone aggregates as in sub base of floor, complete all as specified and directed.
50mm thick PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates as in flooring and finishing the surface even and smooth using extra cement complete all as specified and directed.
Rolled mild steel work in tubular trusses and posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as directed.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe - 290 (Gde E-165) complete all as specified and as directed.
Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30cm long, diametre of neck 20mm complete all as specified and as directed.
M&L for pre-painted galvalume aluminium zinc coating GI based corructed steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based corructed steel sheet 0.60 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Preparation of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in thick in soils complete all as specified and directed.
Removing excavated material to a distance exc. 500 m but n.exc. 1.50 KM and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick/concrete surfaces on walls with CM (1:4) finished even & smooth without using extra cement complete all as specified and as directed.
Applying two coats of cement base paints on new plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
75mm thick PCC (1:3:6) type C2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays, finished the surface even and smooth without using extra cement including providing joints in between bays and wall, filled with mastic filling using one part of bitumen & three parts of sand complete all as specified and as directed.
SCHEDULE 'A' PART-II : Point wiring with 1.5 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit with clamps not less than 20 mm dia and 1.2 mm thick complete with all fittings and accessories, fixed to walls/ceiling, including factory made sunk type mild steel terminal boxes 1.25 mm thick (wall thickness) conforming to IS-5133 (Part-I) with 3mm thick hylem sheet top cover for mounting switches/ sockets/regulator etc including 1.5 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One light point/ One fan point/bell point controlled by one No 5 Amp switch complete all as specified and as directed.
Description as per item No 26 here-in before but for one 5 Amps socket on same board complete all as specified and as directed.
Description as per item No 26 here-in before but for one 5 Amps 5 Pin switch socket combination on independent board complete all as specified and as directed.
Switch piano flush type single pole one way 5 amps, 230 V complete all as specified and as directed.
Ceiling rose, surface, bakelite 65 x 50 mm, three terminals, AC, 230 Volts complete all as specified and as directed.
Socket outlet 3 pin 5 Amp flush type complete all as specified and as directed.
Switch socket combination 2 in1, 3 pin 5 and 15 Amp flush type complete all as specified and directed.
Sub main wiring with 2 runs (Phase & Neutral) of single core 2.5 Sqmm (Nominal area) stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through in and including PVC casing caping of required size (ISI Marked) including 1 x 2.5 Sqmm (Nominal area) FRLS PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: Two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm earth continuity conductor including casing caping shall be measured as one run length.
Heavy duty cable 1100 volts grade, PVC insulated stranded aluminium conductor, twin core flat or circular 10 Sqmm cable served with inner sheathing of PVC tape and overall PVC sheathed as in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, complete all as specified and as directed.
GI pipe light grade, 25 mm dia including necessary fittings, fixing clamp to wall, complete all as specified and as directed.
LED batten tube light fittings , 24 W, in extruded aluminium housing with diffuser with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. Make: Crompton Cat No. LCCLB24-24CDL or equivalent model of make Phillips/Wipro/Jaquar/Surya/Magik.
MCB DB , SPN 8 way, double door with 200 Amp rated bus bar, horizontal type IP-43 including earth and neutral link ,complete with fixing accessories all as specified and directed. Make: Legrand/ Schneider/Siemens.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-40 Amps complete all as directed.
S&F MCB SPN, 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-40 Amps complete all as directed.
Ms N D Enterpise
M/s A R Traders
M/s Beekey Seekey Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .