Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAdmitted-Finance AT BENIDIH PO GARSARA PS PALAJORI DIST DEOGHAR JHARKHAND | ₹19.0 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical MAHAGAMA MAHAGAMA MAHAGAMA MAHAGAMA GODDA JHARKHAND 814154 UDYAM JH 09 0004074 | GODDA | JHARKHAND | 814154 | - | - | Rejected-Technical REJECTED BY TCM |
| 3 | Rejected-Technical MAHAGAMA | - | - | Rejected-Technical REJECTED BY TCM |
| Sl No | Description | Qty | Unit | ROY CONSTRUCTIONS L1 |
|---|---|---|---|---|
| 1.00Item Description/ Heading | ||||
| 1.01 | Providing of 3.3 KV grade fail safe relay and earth leakage relay system voltage 3.3 KV with resin cast potential transducer, CT with Set | 4 | Nos | 2,56,650 ₹10.3 L |
| 1.02 | Providing of electronic buzzer aux supply220VAC | 4 | Nos | 2,685 ₹10,740 |
| 2.00 | Providing of plug-in relay with base, Aux supply-220VAC | 12 | Nos | 4,530 ₹54,360 |
| 3.00 | Installation, Testing and commissioning of 3.3KV grade NGR system | 4 | Nos | 71,000 ₹2.8 L |
| 4.00 | Control wiring of NGR and Panel both side | 4 | Nos | 18,650 ₹74,600 |
| 5.00 | Contractor's profit @ 10% Rs. | 1 | Nos | 1,44,000 ₹1.4 L |
| 6.01 | CMPF 12% on labour cost Rs. | 1 | Nos | 18,103.2 ₹18,103.20 |
| 6.02 | CMPS @7% | 1 | Nos | - |
| 7.00 | Total impact of GST for the purpose of CTC | 1 | Nos | 2,90,232.58 ₹2.9 L |
Tender Value
₹19.0 L
EMD Value
₹23,800
Closing Date
20 Mar 2026, 5:00 pmClosed
AREA ENGINEER E AND M
AT PO CHITRA DEOGHAR JHARKHNAD
Providing installation and commissioning of 04 nos of 3point 3 KV Neutral Ground resister complete with NGR monitoring system and new earth fault relay for 33or11or3point 3 KV main substation at Chitra Colliery S.P Mines AREA
2026_ECL_356344_1
ECL/SPM/GM/EM/eNIT/1-8/2526/47
Open Tender
Electrical and Maintenance Works
7 days
Chitra Colliery S P Mines Area
please refer nit documents
6 documents required · 6 mandatory
₹23,800
Yes
27 Mar 2026
11 Mar 2026
21 Mar 2026
11 Mar 2026
20 Mar 2026
12 Mar 2026
11 Mar 2026 - 14 Mar 2026
Item Description/ Heading
Providing of 3.3 KV grade fail safe relay and earth leakage relay system voltage 3.3 KV with resin cast potential transducer, CT with Set
Providing of electronic buzzer aux supply220VAC
Providing of plug-in relay with base, Aux supply-220VAC
Installation, Testing and commissioning of 3.3KV grade NGR system
Control wiring of NGR and Panel both side
Contractor's profit @ 10% Rs.
CMPF 12% on labour cost Rs.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 1.04 MB
BOQ_369186.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid