| 1 | L1₹19.0 LAdmitted-Finance AT BENIDIH PO GARSARA PS PALAJORI DIST DEOGHAR JHARKHAND | ₹19.0 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical MAHAGAMA MAHAGAMA MAHAGAMA MAHAGAMA GODDA JHARKHAND 814154 | GODDA | JHARKHAND | 814154 | - | - | Rejected-Technical REJECTED BY TCM |
| 3 | Rejected-Technical MAHAGAMA | - | - | Rejected-Technical REJECTED BY TCM |
| Sl No | Description | Qty | Unit | ROY CONSTRUCTIONS L1 |
|---|---|---|---|---|
| 1.00Item Description/ Heading | ||||
| 1.01 | Providing of 3.3 KV grade fail safe relay and earth leakage relay system voltage 3.3 KV with resin cast potential transducer, CT with Set | 4 | Nos | 2,56,650 ₹10,26,600 Lowest |
| 1.02 | Providing of electronic buzzer aux supply220VAC | 4 | Nos | 2,685 ₹10,740 Lowest |
| 2.00 | Providing of plug-in relay with base, Aux supply-220VAC | 12 | Nos | 4,530 ₹54,360 Lowest |
| 3.00 | Installation, Testing and commissioning of 3.3KV grade NGR system | 4 | Nos | 71,000 ₹2,84,000 Lowest |
| 4.00 | Control wiring of NGR and Panel both side | 4 | Nos | 18,650 ₹74,600 Lowest |
| 5.00 | Contractor's profit @ 10% Rs. | 1 | Nos | 1,44,000 ₹1,44,000 Lowest |
| 6.01 | CMPF 12% on labour cost Rs. | 1 | Nos | 18,103.2 ₹18,103.2 Lowest |
| 6.02 | CMPS @7% | 1 | Nos | - |
| 7.00 | Total impact of GST for the purpose of CTC | 1 | Nos | 2,90,232.58 ₹2,90,232.58 Lowest |
Tender Value
₹19.0 L
EMD Value
₹23,800
Closing Date
20 Mar 2026, 5:00 pmClosed
AREA ENGINEER E AND M
AT PO CHITRA DEOGHAR JHARKHNAD
Providing installation and commissioning of 04 nos of 3point 3 KV Neutral Ground resister complete with NGR monitoring system and new earth fault relay for 33or11or3point 3 KV main substation at Chitra Colliery S.P Mines AREA
2026_ECL_356344_1
ECL/SPM/GM/EM/eNIT/1-8/2526/47
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Chitra Colliery S P Mines Area
please refer nit documents
6 documents required · 6 mandatory
₹23,800
Yes
27 Mar 2026
11 Mar 2026
21 Mar 2026
11 Mar 2026
20 Mar 2026
12 Mar 2026
11 Mar 2026 - 14 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Item Description/ Heading | |||||
| 1.01 | Providing of 3.3 KV grade fail safe relay and earth leakage relay system voltage 3.3 KV with resin cast potential transducer, CT with Set | 4 | Nos | - | - |
| 1.02 | Providing of electronic buzzer aux supply220VAC | 4 | Nos | - | - |
| 2 | Providing of plug-in relay with base, Aux supply-220VAC | 12 | Nos | - | - |
| 3 | Installation, Testing and commissioning of 3.3KV grade NGR system | 4 | Nos | - | - |
| 4 | Control wiring of NGR and Panel both side | 4 | Nos | - | - |
| 5 | Contractor's profit @ 10% Rs. | 1 | Nos | - | - |
| 6.01 | CMPF 12% on labour cost Rs. | 1 | Nos | - | - |
| 6.02 | CMPS @7% | 1 | Nos | - | - |
| 7 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 1.04 MB
BOQ_369186.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .