| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.4 L+₹4.7 L (21.5%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹27.0 L+₹5.3 L (24.6%)Rejected-AOC ROOM NO 214 GANESH MURTHY NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-AOC L3 | |
| 4 | L4₹27.3 L+₹5.6 L (25.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹28.4 L+₹6.7 L (31.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
20 Mar 2021, 6:00 pmClosed
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN 500043
REPAIRS TO STREET LIGHTS HIGH MAST LIGHTS POST TOP LANTERNS IN THE INNER ROADS AT AFA HYDERABAD
2021_MES_423542_1
8135/02/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AFA) Hyderabad
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹50,000
Yes
9 Apr 2021
19 Feb 2021
22 Mar 2021
19 Feb 2021
20 Mar 2021
6 Mar 2021
19 Feb 2021 - 2 Mar 2021
Amount
Attending day to day maintenance for checking the serviceability / repairing all Security lights / Post top lanterns / Flood lights / Dispersal lights and TMS / Hanger lights including disconnecting and taking down unserviceable all type of light fitting (LED/HPSV/MH/CFL fittings etc.) of any type and make complete from the PCC Pole / Steel tubular poles / High mast / building along the inner road of all AFA Area , including repairs to unserviceable wiring, connectors at pole junction boxes / connecting from OH lines to light fittings, minor supplying of spares like holders, connectors, screws washers etc and reconnecting / refixing and testing complete all as directed.
Note:- (i) Necessary defective spares which are required to be replaced to make proper functioning of all type security lights, shall be measured and paid seperately under relevent items as directed by Engr-in Charge.
(ii) Contractor will have to provide well experienced 1 No Electrician with 1 No Helper along with vehicle, tools and ladder etc for checking the serviceability/repairing on requirement basis in addition to man power required for execution of other routine works.
(iii) All Tools & Plants required for repair work shall be provided / arranged by the contractor at his own arrangement and expense to the trade men & helpers.
(iv) All complaints should be attended with in 24 hours of reporting of complaints. Penalty charges for non attending complaints with in 24 hrs shall be Rs 300/- per complaint .
(v) A joint inspection for checking of serviceability of security lights will be carried out with contrator's representative, user's representative and MES personal in every week.
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 25 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTS-25-CDL-M/ Havells(ENDURAPEARLSL25WLED757SASYTOPCMP)/Luker(LST24) /Bajaj(BRLEP25WLED WH)
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 30 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTS-30-CDL-M/ Havells(ENDURAPEARLSL30WLED757SASYTOPCMP)/Luker(LSTE30) /Bajaj(BRLEP30WLED WH)
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 1 x 45-48 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTS-45-CDL-M/ Havells(ENDURAPEARLNEOSL45WLED757PASYTOPC)/Luker(LST48) /Bajaj(BRLEP45WLED V2)
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 70-72 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTP-72-CDL-M/ Havells(ENDURACITYLINERNEOOSL70WLED757PASYBOTG)/Luker(LST72) /Bajaj(BRLEP72WLED V2)
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 90 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTP-90-CDL-M/ Havells(ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO)/Luker(LST90) /Bajaj(BRLEP90WLED V3)
Supply and fix LED Flood light fitting 50 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution, including taking out the existing unserviceable complete all as specified and as directed. Make: Crompton(LFL-50-CDL/60-M/ Havells(JETAQUANTOPLUSFLP50WLED757SYMLENS)/Luker(LFL50SEN) /Bajaj(BJFL150WLED-I )
Supply and fix LED Flood light fitting 150 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution,including taking out the existing unserviceable complete all as specified and as directed. Make: Crompton(LFLN-150-CDL/60-M/ Havells(JETAIRISFLS150WLED757PSYMLTG)/Luker(LFLSL150) /Bajaj(BJFL50WLED I )
Supply and fix LED Flood light fitting 350 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution,including taking out the existing unserviceable complete all as specified and as directed. Make: Crompton(LSFO-350-CDL/60-M/ Havells(JETAVALOURFL350W3MLED757MODNBLTG)/Luker(LFLHL350) /Bajaj(BJFL350WLED)
Supply and fix LED Narrow Beam Light fitting 9/10 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution,including taking out the existing unserviceable complete all as specified and as directed. Make:-Luker LODWW10 OR Equivallent in CG/Baja/ Phillips/Havells
Supply and fix RGB Flood light fitting 30 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution, including taking out the existing unserviceable complete all as specified and as directed. Make:-Luker/Oreva/Bajaj/Fortune Arts
Supply and fixing in repairs of Aviation obstruciton lights LED lights 302 Nos, Yellow aluminum housing red coloured polycarbonate enclosure and accessories complete all as specified and as directed. . . Make :- Bajaj/K-Light/Eye Light/Precise Technologies
Supply & fixing including taking out unserviceable electronic driver for LED street light upto 30 watt complete all as directed. Note :- Driver will be procured as per sample, as required at site compatable for existing light fittings
Supply & fixing including taking out unserviceable electronic driver for LED street light 45 / 50 watt complete all as directed. ote :- Driver will be procured as per sample, as required at site compatable for existing light fittings
Supply & fixing including taking out unserviceable electronic driver for LED street / flood light 70 to 150 watt complete all as directed. note :- Driver will be procured as per sample, as required at site compatable for existing light fittings
M&L for repairing of Electronic chip, suitable for LED Street light upto 20/25/30 watt capacity, by replacing faulty electronic components to make the light fitting serviceable complete all as specified and as directed. Note :- Chip will be procured as per sample, as required at site compatable for existing light fittings
M&L for repairing of Electronic chip, suitable for LED Street light upto 45/50/60 watt capacity, by replacing faulty electronic components to make the light fitting serviceable complete all as specified and as directed. Note :- Chip will be procured as per sample, as required at site compatable for existing light fittings
Supply & fixing including taking out unserviceable Surge Protection Device for LED street/flood light rated power above 75W upto 150W complete all as directed. Note :- Note :- Surge Protection Device will be procured as per sample, as required at site compatable for existing light fittings
Supply & fixing electronic ignitors suitable for 70 watts SV/MH lights including taking out unserviceable one complete all as directed.Make :- CG/Bajaj/ Havells
Supply & fixing electronic ignitors suitable for 150 watts SV/MH lights including taking out unserviceable one complete all as directed.Make :- CG/Bajaj/ Havells
Supply & fixing electronic ignitors suitable for 250 watts SV/MH lights including taking out unserviceable one complete all as directed. Make :- CG/Bajaj/ Havells
Supply & fixing including taking out unserviceable capacitor suitable for SV/MH lights Fittings of capacity 70 watts complete all as directed. .
Supply & fixing including taking out unserviceable capacitor suitable for SV/MH lights Fittings of capacity 150 watts complete all as directed. .
Supply & fixing including taking out unserviceable capacitor suitable for SV/MH lights Fittings of capacity 250 watts complete all as directed. .
Supply & fixing including taking out unserviceable ballast electromagnetic type suitable for 70 watts SV/MH light fittings complete all as directed. . Make :- CG/Bajaj/ Havells/Philips
Supply & fixing including taking out unserviceable ballast electromagnetic type suitable for 150 watt SV/MH light fittings complete all as directed. . Make :- CG/Bajaj/ Havells/Philips
Supply & fixing including taking out unserviceable ballast electromagnetic type suitable for 250 watt SV/MH light fittings complete all as directed. . Make :- CG/Bajaj/ Havells/Philips
Supply & fixing bulb tubular thread type suitable for 70 watt SV/MH light fitting including taking out unserviceable lamp complete all as directed. .
Supply & fixing bulb tubular thread type suitable for 150 watt SV/MH light fitting including taking out unserviceable lamp complete all as directed. .
Supply & fixing bulb tubular thread type suitable for 250 watt SV/MH light fitting including taking out unserviceable lamp complete all as directed. . .
Taking out the existing unserviceable Traffic Signal Blinker light fittings of any description and supply and fix new LED Blinker light 20Watt (Traffic Signal Light) fittings including suitable clamp, electrical connections etc complete all as directed.
Excavation in trenches in soft / loose soil not exc 1.5 m wide and not exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
Excavation in trenches in hard / dense soil not exc 1.5 m wide and exc 1.5 m but not exc 3.0 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and as directed.
Re laying of old retreived bricks vide excavation in trenches of exisitng laid cables complete all as specified and as directed.
M&L for brick sub class B locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 35 sqmm 3.5 core including removing and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 25 sqmm 3.5 core including removing and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 16 sqmm 4 core including removing and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 10 sqmm 4 core including removing and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 10 sqmm 2 core including removing and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 50 mm complete all as specified and as directed .
M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 40 mm complete all as specified and as directed .
Boring of holes under road, pavement hard standing by using trenchless technology using ultrasound technique and necessary machine to insert pipe of 50 to 100mm light grade GI pipes as per site requirement with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, alongwih Butt fusion welding machine with all accessories, T&P etc required all as specified and as directed. Note :- Protection pipe will be measured and paid separately
M&L for Re Stringing and Fixing only in position of sagged ACSR conductor of required size in over head line including binding with aluminium binding wire complete after removing and refixing of UG cables/services wires to the ACSR conductor complete all as specified and as directed by the Engr-in-charge
Supply & Fix PVC LT line separators 4 way with nut, bolt arrangement, in the existing O/H line on pole on height 7.0-7.50 mtrs above ground level conductor complete all as specified and as directed .
Trimming of trunk and branches of trees not exceeding 30 cm grith and disposal of the same to a distance n.exc 50m and clearing site complete all as directed to clear the OH line (HT/LT) for a span irrespective of length. complete all as specified and as directed .
M&L for Cutting of Vegetations, creapers, grasses, earth heaps etc, cleaning and levelling of cutting areas in various electrical installation areas, surrounding of HT/LT poles/structures complete all as specified and as directed .
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping to pole for embedding stay road all as specified, including necessary form work and applying two coats of white wash to exposed surface of coping / platform complete all as specified and as directed .
M&L for PCC 1:3:6 type C-2 mix using 40 mm graded stone aggregate for foundation / platform / pedestal / stay wire etc, complete all as specified and as directed .
S & F cable junction box 200 x 160 x 98 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, unts, bolts, washers etc., including taking out of old unserviceable cable junction box complete all as specified and as directed Make Cat No . K-9250 of HENSEL or equivalent in SPELSBERG / RITTAL/SINTEX
S & F cable junction box 167 x 125 x 82 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, unts, bolts, washers etc., including taking out of old unserviceable cable junction box complete all as specified and as directed Make Cat No . D-9100 of HENSEL or equivalent in SPELSBERG / RITTAL/SINTEX
M&L for cable two core PVC insulated, PVC sheathed multi stranded aluminium conductor cable size 2.5 Sqmm for connection junction box to security light complete all as specified and as directed .
Removing the existing unserviceable GI pipe bracket along with clamps and supply and fix GI pipe light grade bracket 32 mm dia, 1.2 mtr long bent to shape as required and fixed with suitable size of MS clamps, (40 mm x 5 mm MS Flat) nut, bolt, washers etc to poles/walls complete all as directed.
M&L for Painting to the existing cross arms /clamps / bracings/ nuts bolts and washers complete with two coats of Aluminium paint after cleaning the surfaces at height of 7 to 8.5 mtrs pole above ground level with out disturbing the conductors completely and making good complete all as specified and as directed
S&F all in one integrated Solar Smart LED Street light fitting 30 Watt, Solar panel of 6V 12W Polycrystalline type should be on the top of the fitting with Lithium- Ferrous Battery of 24 AH , pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution including suitable GI pipe bracket, complete all as specified and as directed. Make:- Luker/Havells/Phillips/Bajaj/Crompton
Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32 x 6 mm as earth lead by means of brazing etc all as shown in electrical plate No 3 connected to earthing test point as specified or indicated including testing on completion. Note:- (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. 3) All the joints should be brazed only brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed ..
M&L decorative gate lights made up unbreakable polycarbonate matireal suitable for 20W LED with B22 base commplete all as specified and directed Make : Havell/Luker/Philips/Bajaj/Crompton
M&L decorative gate lights made up of high grade unbreakable polycarbonate material suitable for 7W LED with B22 base commplete all as specified and directed Make : Havell/Luker/Philips/Bajaj/Crompton
Supply and fixing IP-65 rated LED Bollards fitting black painted MS housing with cast aluminium dome shaped threaded top cover with cylindrical,reeded poly carbonate diffuser and accessories suitable for 10 watt LED lamp including nuts, bolts and washers for fixing complete including all fixing arrangements/ footing/ foundation all as directed by Eng-in-charge. Make Crompton Cat part No-LBLTW-10-CDL equivalent in Luker/Havells/Phillips/Bajaj
S & F TPN tier distribution board IP-43 double door 12 +2 way MCCB + 6+36 modules . Complete with following and all as specified and directed make Hager Cat Part No.VYP12DM or equivalent in Havells/L&T/C&S/Legrand (i) MCCB,4P,160A-01No. (ii) MCB,SP,6 to 32A-36 (iii) MCB,TP,6 to 32A-3Nos.
M&L decorative robust and reilable LED Post top light 30 watt with transperant diffuser Complete all as specified and directed MakeC&S , Cat Part LTGLC30WHPLED/W or equivalent in Luker/Havells/Phillips/Cromption/Bajaj
M&L for Repairing of Street Light Timer Panels Indoor /Outdoor type 415Volts,50Hz including replacement of Spare parts and all as directed by Engineer-In-Charge. Note: Spare parts will be measured and paid separately under relavent item No. 66 to 76
(i) Checking/Overhaulin/repairing of MCCB 4 pole 63 Amps to 120Amp, 25 KA, 415 Volts, 50 HZ, AC supply, - 01 Nos(Incoming)
(iv) Checking/repair/replacement of Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply - 01 No
(v) Checking/repair/replacement of 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No
(vi) Checking/repair/replacement of LED indicating lamps with holder for main supply - 1 Set of 3 (R-Y-B)
Supply only MCCB 4 pole 63 Amps, 25 KA, 415 Volts, 50 HZ, AC supply, Make: Havells/L&T/C&Sv
Supply onlyMCCB 4 pole ,120Amp, 25 KA, 415 Volts, 50 HZ, AC supply, Make: Havells/L&T/C&S
Supply only Voltmeter, digital type,0-500V,AC, 96x96mm Make: AE/MECO/L&T
Supply onlyAmmeter digital type,CTR 5A, 96x96mm Make; AE/MECO/L&T
Supply onlyCT's 63/5Amps Class 1 accuracy-01Set
Supply onlyCT's 120/5Amps Class 1 accuracy-01Set
Supply only Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply.Make: L&T/GIC/Legrand
Supply only of 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No Make:L&T//Havells/C&S
Supply only LED ,230Volts AC indicating lamps with holder for main supply (R-Y-B)
M&L straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 10 to 35 sqmm 3.5/4.0 core and testing complete all as specefied and as directed.
Supply only LED strip outdoor type blue/red/green with strip driver 14.6 watt 12 volt 50 hz complete all as specified and directed Make : Luker cat part No.LS05050 OR equivalent in Havells/CG/Fortune Arts
Servicing, Greasing and repairing High mast lights including disconnecting and taking down unserviceable all type of light fitting (LED/HPSV/MH fittings etc.) of any type and make complete from the Steel tubular poles / Octagonal pole of High mast , including repairs to unserviceable gears, pulley, bearing, flexible stainless steel wire/jointing of wire and gaskets including wiring, connectors at pole junction boxes / connecting from light fittings, minor supplying of spares like gaskets, connectors, screws, washers etc and reconnecting / refixing after testing complete all as directed.
Note:- (i) Necessary defective spares which are required to be replaced to make proper functioning of all type High mast lights, shall be measured and paid seperately under relevent items as directed by Engr-in Charge.
(ii) Contractor will have to provide well experienced 1 No Electrician with 1 No Helper along with vehicle, tools and ladder etc for checking the serviceability/repairing on requirement basis in addition to man power required for execution of other routine works.
(iii) All Tools & Plants required for repair work shall be provided / arranged by the contractor at his own arrangement and expense to the trade men & helpers.
Supply only of 3 Pole power contactor of AC 3 duty rating of 63 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No
Supply only of Auxilary contact ,2 No 0.5 module having 240 volts rated ,Complete all as specified and directed
Supplying , laying & testing in maintenance copper trailing cable 5 core 4 sqmm FRLS insulated PCP scheathed connected high mast lights confiring to relevant IS specification including dismantling and taking out the unserviceable cable complete all as specified and directed
M&L for repairing of feeder pillar box by welding of broken door with new accessories and making all doors to freely operatable by using grease and applying two coats of spray paint approved shade complete all as specified and directed
Sypplying and fix under water LED light 12 watt 220 volt of aluminium body RGB in colour 50 hz. complete all as specified and directed. Make: Luker/Havells/ CG/Bajaj/Phillips/C&S/Fortune Arts
RAJU AND CO
Pragathi Infrastructure Co.
M.chandraiahsons
RAJU ENTERPRISES
POWER CONSTRUCTION COMPANY
Srinivasa Consructions
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .