Closing Date
22 Jun 2026, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist-Darjeeling, WB-734009
REPAIR AND MAINT OF DIFFERENT CAPACITY DG SETS, CABLES, SWITCH GEARS AND OTHER MISC E/M WORKS UNDER AGE E/M OF GE SUKNA AT MIL STN SUKNA
2026_MES_768142_1
GE Sukna/9045
Open Tender
Civil Works
Works
180 days
SUKNA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SUKNA
₹90,000
20 Jun 2026
27 May 2026
24 Jun 2026
28 May 2026
22 Jun 2026
15 Jun 2026
28 May 2026 - 22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for daily inspection, maintenance and servicing of all DG sets of following capacity and locations including Alternator, AMF/ Non AMF panels of connected DG set for daily routine check ( 'A' - check as specified below ) for smooth functioning as per the Manufacturers instructions by Employing experienced one DG Mechanic etc. complete all as specified and as directed by the Engineer-in-Charge. 'A' Check/ daily routine check by each Month include the followings for item No.1 :-(i) Check Engine oil level and toping up as and when required (Engine oil shall l be supplied by MES free for filling )(ii) Check Engine Coolant level if required top up (Coolant shall be measured and paid separately under relevant item)(iii) Check Belts if there is belt slippage adjust or replace(New belt shall be measured and paid separately under relevant item] (iv) Check oil bath cleaner oil level .(v) Check Exhaust System for leakage. (vi) Drain sediment from Fuel filter & Fuel Tank.(vii) Check dry type air filter element and clean or replace (Replacement required shall be measured and paid separately)(viii) Check engine alternator coupling and mounting bolts. (ix) Tight all bolts and nuts in Alternator Terminal Box.(x) Check carbon brushes (Brush type) and connections in Alternator.(xi) Check and tight all Electric connections in DC control wiring.(xii) Check all Radiator rubber Hoses.(xiii) Record oil pressure, water and oil Temp.(xiv) Record RPM, Voltage, AMPS and Hz(xv) Check Anti Vibrating Mountings.(xvi) Check throttle linkage.(xvii) Check starting battery electrolyte level and specific gravity, top up level regularly Note for item No.1.00 to 1.38:i) Routine check / repair work of AMF Panel will be measured and paid separately under respective item of sch here in after. | 9 | Per Month | - | - |
| 1.01 | ii) Repair/maintenance of Panels of DG set other than AMF panel is deemed to be inclusive of rate except control switches ie MCCB/ Main Switch/ Voltmeter, Ammeter, Hz meter, Selector switches and CT's etc.,
1.02 DG set 320 KVA installed at signal centre 1.03 DG set 180 KVA installed near Signal centre 1.04 DG set 82.5 KVA installed at MAP-2
1.05 DG set 82.5 KVA installed at U area main PH 1.06 DG set 63 KVA installed at Signal centre 1.07 DG set 62.5 KVA installed at U area offrs enclave 1.08 DG set 62.5 KVA installed at U area OC PKT PH 1.09 DG set 62.5 KVA installed at U area JCO Accn PH 1.10 DG set 62.5 KVA installed at TRHS 1.11 DG set 62.5 KVA installed at MAP-2. 1.12 DG set 50 KVA installed at 15 mahar 1.13 DG set 40 KVA installed 12 para (SF)
1.14 DG set 40 KVA installed at 22 DOG Unit 1.15 DG set 40 KVA installed at 108 wkshop 1.16 DG set 35 KVA installed at 33 CSR 1.17 DG set 35 KVA installed at 7033 EME 1.18 DG set 32.5 KVA installed at Taranjubari 1.19 DG set 30 KVA installed at 63 mount brig 1.20 DG set 30 KVA installed at Core PH 1.21 DG set 30 KVA installed at Hopper tank 1.22 DG set 30 KVA installed at Rangpur PH 1.23 DG set 30 KVA installed at Pinaka site 1.24 DG set 30 KVA installed at 5033 ASC 1.25 DG set 25 KVA installed at MAP PH-1 | - | - | - | - |
| 2M&L for inspection, maintenance and servicing of DG sets including Alternator, Non AMF/ AMF panels of connected DG sets for routine check up (B-check once in six month or 250 hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete services as per the manufacturers instructions including items covered in 'A'-Check (Ref item No.1) all as specified for following DG sets:- Note for item No. 2:- Engine oil & Coolant shall be measured paid seperetaly under relevant item. | |||||
| 2.01 | DG set 320 KVA installed at signal centre | 2 | Per Job | - | - |
| 2.02 | DG set 250 KVA installed at signal centre | 2 | Per Job | - | - |
| 2.03 | DG set 250 KVA installed at signal centre | 2 | Per Job | - | - |
| 2.04 | DG set 250 KVA installed at Madhuban PH | 2 | Per Job | - | - |
| 2.05 | DG set 180 KVA installed near Signal centre | 2 | Per Job | - | - |
| 2.06 | DG set 125 KVA installed at Md Accn PH sukna | 2 | Per Job | - | - |
| 2.07 | DG set 82.5 KVA installed at MAP-2 | 2 | Per Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Tenderdoc9045.pdf
Tender Documents • 1.58 MB
BOQ_860336.xls
BOQ • 0.45 MB
datecorrs_9045.pdf
PDF • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .