Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Jul 2020, 6:00 pmClosed
GE West Lucknow
11, Sardar Patel Marg, Lucknow Cantt
REPAIR TO ROOF TREATMENT AND LEAKAGE SEEPAGE IN ZONE C AREA OF AGE BR I UNDER GE WEST LUCKNOW
2020_MES_340751_2
8020/11/E8
Open Tender
Civil Works
Item Rate
240 days
Lucknow Cantt
Class E
Cat a i
7 documents required · 7 mandatory
₹500
GE West Lucknow
₹70,000
Yes
5 Aug 2020
26 Jun 2020
13 Jul 2020
26 Jun 2020
11 Jul 2020
29 Jun 2020
26 Jun 2020 - 29 Jun 2020
Amount
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed.
Supply, fixing, laying & testing 25 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed.
S&F in repair 6mm thick asbestos cement corrugated or semi corrugated sheets in roofs, walls etc. and fixed with 'L' or 'J' hook or cranked hook bolts complete all as specified and directed.
S&F in repair asbestos cement serrated ridge for corrugated or semi corrugated sheets complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 cm thickness(below or above ground level) complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 including demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
Taking down cement or cement lime plaster on walls any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 using WPC as per manufacturer's instructions finished even and smooth without using extra cement complete all as specified and directed. (Water proofing compound shall be measured and paid for seperately under respective item of Schedule 'A').
M & L for preperation of surface of wall/chajja and applying a coat of tapecrete P-151/Cemcrete acrylic polymer modified cementitious slurry consisting of one part of TAPECRETE P-151/Cemcrete and two parts of cement by weight complete all as specified and directed.
Supply only integral water proofing compound(Powder) conforming to IS 2645 complete all as specified and directed.
S & F in repair Gypsum Board 12mm thick (textured finish), white prelaminated sett embossed reinforced designer ceiling boards of approved texture at all height laid on hot dipped GI imposed grid with 24mm wide T sec exposed flanges which shall be pestered coated white. The frame work shall comprise of main runner made from 0.33 mm thick GI sheet of size 24x32x300mm and spaced at 1200 mm C/C securely fixed to the structural soffits by approved hangers at 1200mm c/c. Hangers of GI wire 4mm dia to be fixed by approved rawl plug, screw etc. The last hanger at the end if each main runner shall not be greater than 450mm from adjacent wall, flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runner at 600mm C/C to form 1200x 600 mm modules cross tee longer than 600mm to be supported independently 1200x600 dodules formed by fitting 600mm long cross tee centrally between the 1200mm cross tee. Tee perimeter wall angle shall be made of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacturers instructions complete all as specified and directed.
S&F in repair suspended false ceiling with "E" grid suspended ceiling grid system of grid size 600 x 600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24 x 0.3mm using 4mm thick high pressure steam cured classic variant E-Board, designer pattern to be placed in the grid suspended by 2mm dia GI wire at distance n. exc 1.2m center to center with butterfly clips including preparation of surface and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Ditto all as above Item No 15 but excluding snap grid complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300x200x7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
All as per item no. 20 but on vertical surfaces such as skirting/dados etc over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm / 450x350x7/ 300x450x7mm thick as approved in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm stone aggregate) as in sub base complete all as specified and directed.
Dismantling of stone slabs and tiles of any description and thickness as in floor, apron etc. laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for granite stone 18-20 mm thick (of any type) glazed (table rubbed and polished) fixed as in steps, jambs, pillars, window cills, cooking plateform and the like set in cement mortar 1:4 and pointed with white cement (1:2) using marble dust with admixture of pigment to match and exposed edges rounded with and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed
M&L for machine cut kota stone 20 to 25 mm thick as in steps, risers, skirting, dado etc., bedded and jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of the stone including grinding, rubbing and polishing with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix stone complete all as specified and directed.
M&L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring finished even and smooth using extra cement complete all as specified and directed.
M&L for 75mm thick cement concrete type C2 1:3:6 (using 40 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and fair including forming construction (dummy) joints along the wall and bays 6 mm wide & 10 mm deep and filled with mixture of bitumen and sand in the ratio 1:3 laid at an interval of not exceeding 3 metre and at change of direction complete all as specified and directed.
Supply only glass dividing strip 3 mm thick, 38 mm wide inserted in floor to required design complete all as directed. NOTE:- Rates for fixing shall deem to be included in rates for laying flooring.
S&F in repair bib taps, Brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair pillar taps, brass, with capston heads, fancy type, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair stop valve/angle valve 15 mm nominal bore brass, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S & F in repair 15 mm dia chromium plated brass central hole wash basin mixer (pillar tap) with accessories in wash basins for mixing hot and cold water, screwed down for 15 mm bore GI pipe complete all as specified and directed.
S & F in repair 15 mm dia chromium plated brass wall mixture with provision of overhead shower with 115 mm long bend pipe and wall flange screwed down for 15 mm bore GI pipe complete all as specified and directed.
S&F in repair stop valves 15 mm nominal bore, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for iron pipe or for brass ferrule or to GI socket complete all as specified and directed .
S&F in repair 20 mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe including testing complete all as specified and directed.
S&F in repair 32 mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed.
S & F in repair Brass spindle for fancy type Bib cock/stop cock 15mm bore complete all as specified and directed.
S & F in repair Brass spindle for concealed stop cock 15mm bore complete all as specified and directed.
S & F in repair Brass spindle for fancy type Bib cock/stop cock of Make:- Jaquar / Parryware / Plumber complete all as specified and directed.
S&F in repair PVC low level white flushing cistern valveless syphonic action type 10 lts capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend complete all as specified and directed.
S & F in repair PVC Syphon Kit with complete fittings for low level flushing cistern complete all as specified and directed.
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and directed.
S & F in repair Chromium plated shower rose with or without swivel joints 125mm dia with long arm including fixing to steel pipe or union complete all as specified and directed.
S&F in repair vitreous china wash hand basin white flat back size 550x400 mm including two Nos bracket, 32 mm dia brass CP waste coupling and waste pipe complete all as specified and directed.
S&F in repair Viterous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device including CI 'P' or 'S' trap complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest with CI 'P' or 'S' trap and providing PCC 1:5:10 type E-2 concrete bedding and connecting to flusing cistern complete all as specified and directed.
S & F in repair waste pipe 32mm dia for WHB & sink complete all as specified and directed.
S&F in repair hand shower (Health faucet) with 1 Mtr flexible tube, wall hook bracket etc, complete set of superior quality Make: Jagur or equivalent of Marc/ESS-ESS/Plumber complete all as specified and directed at site.
S & F in repair plastic water closet seat cover, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S & F in repair PVC coloured bath cabinet, overall size 560 x 410mm decorative design with looking mirror including all fittings complete all as specified and directed.
S&F in position rotational moulded polyethylene triple layered water storage tanks 500 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including S&F ball valve 20 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and directed. and dismatling of exisitng tank complete all as directed
S & F in repair PVC tank cover with locking arrangement for 500/1000 ltrs water tank complete all as specified and directed.
Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes exc 250 & n exc 500 ltrs and writing date of cleaning with synthetic enamel paint complete all as specified and directed.
S&F in repair ball valve 20 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and directed.
S&F in repair ball valve 15 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 142 grams) complete all as specified and directed.
S&F in repair ball valve 25 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 455 grams) complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and fixed to walls complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and fixed to walls complete all as specified and directed.
S&F PVC(SWR) bends 110mm dia complete all as specified and directed.
S&F PVC(SWR) bends 75 mm dia complete all as specified and directed.
S&F in repair 20 mm dia brass chromium plated tubular towel rail, D type, 60 cm long between flanges fixed with rawl plug complete all as specified and directed.
S&F in repair Flush Handle for any respective pattern of low level flushing cistern any description complete all as specified and directed.
S & F in repair 32 mm bore Brass chromium plated Waste coupling for wash basin/urinal etc. with inlet and outlet screwed for pipe or connections includding necessary packing, union and cap and fixed complete all as specified and directed.
S & F in repair 40 mm bore Brass chromium plated Waste coupling for kitchen sink with inlet and outlet screwed for pipe or connections includding necessary packing, union and cap and fixed complete all as specified and directed.
S & F in repair fancy type chromium plated Soap dish 100mm size complete all as specified and directed.
S & F in repair stainless steel grating doom with out hole 100mm dia complete all as specified and as directed.
M & L for preparation of new surfaces of wall and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L applying two coats of white washing on wall surface including preparation of old treated surface complete all as specified and directed.
M & L applying two coats of oil bound distemper over a coat of wall care putty minimum 1 mm thick including preparartion of new plastered untreated surface complete all as specified and directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M & L cement concrete type B-0 (1:2:4) (12.5mm graded stone aggregate) as in roof padding for levelling / maintaining slope etc complete all as specified and directed.
M & L Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete including flashing and junction of parapets etc and surface painting with a layer of hot blown bitumen of any penetration applied hot @ 1.2 kg per sqm, blinded with grit or pea size gravel @ 0.006 Cum per sqm and lightly tempered (area of flashing etc shall be added to the roof area) over and including applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed.
M & L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in roof kerbs, benching, coping, kneelers complete all as specified and directed.
S & F in repair PE AL PE composite pipe size 16mm (out side dia) Make-Nexgen.
S & F in repair PE AL PE composite pipe size 32mm (out side dia) Make-Nexgen.
S & F in repair PE AL PE composite Female Tee size 12 x 16mm Make-Nexgen.
S & F in repair PE AL PE composite tee size 32 x 25 x 20mm Make-Nexgen.
S & F in repair PE AL PE composite tee size 32 x 25 x 16mm Make-Nexgen.
S & F in repair PE AL PE composite tee size 32 x 32 x 32mm Make-Nexgen.
S & F in repair PE AL PE composite coupler / union size 12 x 16mm Make-Nexgen.
S & F in repair PE AL PE composite Elbow size 12 x 16mm Make-Nexgen.
M & L for plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
S&F in repair 75 mm dia cast iron nahani trap, with CP grating including jointing to waste pipe and fixed in cement concrete 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed.
S&F in repair 100 mm dia cast iron nahani trap, with CP grating including jointing to waste pipe and fixed in cement concrete 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed.
S&F in repair cast iron sand cast soil, waste and vent pipe 100 mm bore in any length with or with out ears with cement joints fixed to wall complete all as specified
S&F in repair cast iron sand cast soil, waste and vent pipe 75 mm bore in any length with or with out ears with cement joints fixed to wall complete all as specified
S&F in repair cast iron sand cast soil, waste and vent pipe 100 mm bore in any length with or with out ears with cement joints laid in trenches or in floor complete all as specified
S&F in repair cast iron sand cast soil, waste and vent pipe 75 mm bore in any length with or with out ears with cement joints laid in trenches or in floor complete all as specified
S&F 100 mm bore CI bend(any radius), diminishing pieces or tapers (large bore measured) complete all as specified and directed.
S&F 100 mm bore CI bend(any radius), diminishing pieces or tapers (large bore measured) with oval access doors complete all as specified and directed.
S&F 75 mm bore CI bend(any radius), diminishing pieces or tapers (large bore measured) complete all as specified and directed.
S&F 75 mm bore CI bend(any radius), diminishing pieces or tapers (large bore measured) with oval access doors complete all as specified and directed.
S&F CI cowl 75 mm bore fixed with cement joint complete all as specified and directed.
Removal of vegetation growth n. exc 30cm girth from the bldg around RCC/PVC tank/mumty, chajjas of any height including removal of its roots, branches and making good the disturbed surface in CM 1:4 complete all as specified and as directed.
M&L for cleaning the mouth of rain water pipe at terrace and grouting all around the mouth of pipe to get leak proof joint using CM 1:4 mixed with 3% water proofing compound by weight of cement. Note:- (a) Water proofing compound shall be measured and paid separately. (b) Area of grouting n. exc 0.1 sqm.
M & L for provision of roof treatment with polymeric water proofing membrane all as given below :- (a) Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc. and removing the material retrieved to a distance not exceeding 500 m where directed. (b) Applying a coat of bituminous primer conforming to IS : 3384-1986 @ 0.25 Iitres/sqm on prepared surface and allowed to dry. (c) Applying and laying 3mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10cm and 15 cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3. (d) M & L for cement concrete tiles 25 cm x 25 cm x 20-22mm thick, machine pressed, set, jointed and pointed in neat cement slurry as in floors/terraces over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Cleaning the concrete surface by brushing & watering and applying a coat of tapecrete P-151 Acrylic Polymer Modified cementitious slurry consisting of one part of TAPECRETE P-151 and two parts of cement by weight and shall be allowed to dry for 4-6 hours. Applying a coat of TAPECRETE brush topping 1.5mm thick consisting of one part of TAPECRETE P-151, two parts of cement and two parts of silica sand by weight and cured to 2 days complete all as specified and directed.
M & L for provision of roof treatment with polymeric water proofing membrane all as given below :- (a) Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc. and removing the material retrieved to a distance not exceeding 500 m where directed. (b) Applying a coat of bituminous primer conforming to IS : 3384-1986 @ 0.25 Iitres/sqm on prepared surface and allowed to dry. (c) Applying and laying 3mm thick APP membrane having non oven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10cm and 15 cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3. (d) M & L for applying two coats of aluminium paint on membrane @ 0.10 Kg/Sqm (each coat) complete all as specified and directed.
M & L for providing water proofing treatment to sunken floors all as given below :- (a) Making fillet of size 25mm x 25mm at corner of slab and wall with polymer modified cementitious (PMC) mortar consisting of one part of tapecrete P-151, two parts of cement and 6 parts of fine sand by weight. (b) Sealing of joints of pipe with epoxy putty CICO POXY LC or epoxy mortar CICO POXY 2125. (c) Cleaning the concrete surface by brushing & watering and applying a coat of tapecrete P-151 Acrylic Polymer Modified cementitious slurry consisting of one part of TAPECRETE P-151 and two parts of cement by weight. The coating shall be carried out upto 300mm above FFL and shall be allowed to dry for 4-6 hours. (d) Appying a coat of TAPECRETE brush topping 1.5mm thick consisting of one part of TAPECRETE P-151, two parts of cement and two parts of silica sand by weight and cured to 2 days. (e) Applying 15mm thick plaster in CM 1:4 mixed with CICO super @ 100ml per 50 Kg cement on treated surface.
M/S Reliance Construction
suniltraders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .