Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.4 LAccepted-AOC | 1 | Accepted-AOC AOC | |
| 2 | 2₹29.2 L+₹68,159 (2.39%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹29.4 L+₹88,500 (3.11%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹29.6 L+₹1.1 L (3.98%)Rejected-Finance HIG 05 SECTOR G LDA COLONY KANPUR ROAD LUCKNOW 226012 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226012 | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹30.3 L+₹1.8 L (6.38%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
26 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
229 MG ROAD LUCKNOW CANTT LUCKNOW
SPL REPAIR TO BLDG NO T-45(ORs PERSONAL LINE) CMDC (CC)UNDER GE (E/M) LUCKNOW
2020_MES_397835_1
CWE/LKO/EM/T-28 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Lucknow
MES contractors enlisted in Class D and category a(i) and for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work and having executed similar nature of work
8 documents required · 8 mandatory
₹500
Yes
GE EM LUCKNOW
₹76,000
Yes
6 Jan 2021
24 Nov 2020
28 Dec 2020
24 Nov 2020
26 Dec 2020
10 Dec 2020
60 days
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over (unframed) in section in any position complete all as specified and directed.
S&F rolled setion gde Fe 410 -W (Gde- E- 250) quality as in main and cross beams, hip and jack rafters,purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates incl. rivets or bolt complete all as specified and directed.
S & F MS nut & bolt n.exc 12mm dia and length n.exc 5 cm long complete all as specified and directed.
M&L for 2nd class hard wood in scantling clean sawn timber framed and fixed complete all as specified and directed.
M&L for preparing new steel steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling of AC sheets of any description including ridges in roof covering complete all as specified and directed.
S&F 0.50 mm thick Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting made to any shape or semi-ciruclar any colour having tensile strength of 550 Mpa as in roof covering/ cladding jointed with tapping screw complete all as specified and directed.
All as per item No 8 here-in -before but plain sheet on ridge complete all as specified and directed.
S&F for 1mm thick plain MS sheet in valley gutters, galvanised class 3 half round of length and girth as fixed with rounded edges complete all as specified and directed.
M&L providing, plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation, etc)or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L Suspended ceiling, comprising of 12.5 mm thick reinforced gypsum plaster boards Conforming to IS-2095, GI perimeter channels, intermdiate channels, etc. including finishing the exposed surfaces with 2 mm thick putty & two coats oil bound distemper over a coat of primer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( including backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and including 10mm thick screed in CM 1:4 complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in cement mortar complete all as specified and directed.
M&L 18-20mm thick machine cut Kota stone slab flooring with marble stone strips/ slab/ tiles as per design approved, over and including cement mortar screed bed 20 mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade complete all as specified and directed.
M&L 18-20mm thick machine cut Kota stone slab as in skirting /riser over cement screed bed 15 mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing complete all as specified and directed.
Grinding of old kota stone flooring upto mirror finish level including polisihig etc complete all as specified and directed.
M&L 18-20 mm thick granite stone slab ( Black colour), bedded over and including screed bed 20 mm thick in cm 1:6 and jointed in cement mortar to match the colour of slab as in flooring, polishing and grinding complete all as specified and directed.
Taking down chowkhats or frame (wooden/aluminium) n. exc. 1.5 Sqm each with shutters (with out taking off shutters from the frame) complete all as specified and directed.
Taking down chowkhats or frames (wooden/aluminium) with shutters without taking off shutter from the frames exc. 1.5 Sqm but n. exc 4 sqm each complete all as specified and directed.
S&F Aluminium Anodised ventilator curved shaped fixed with reflective type glass, aluminium section weighting 0.55 Kg/m incl necessary joining cleats, glazing clips rubber neoperene at bottom pannel and top panel with wire cloth of 0.46 nominal dia of wire and average width of aperature 1.4 mm complete all as specified and directed.
S&F aluminium grill 6mm dia not less than 4 Kg per sqm fixed with frame in windows/ventilator complete all as specified and directed.
S&F anodised Aluminium alloy sections sliding windows shutters with frames comprising Series -C (20mm), 2 track sliding shutters duly fitted with neoprene beading, glazing clips,locking device, heat absorbing glass 4.8 mm nominal thickness complete all as specified and as directed.
S&F for aluminium anodised door frame with shutter, incl necessary joining cleats, glazing clips rubber neoprene packing, Handle 2 Nos in each door, 4 Nos 100mm hinges, 1 Nos 200mm aluminium anodised tower bolt anodised aluminium snap beading, screw, necessary locking arrangement with mortice lock with duplicate key complete all as specified and directed.
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc and pre cast concrete articles complete all as specified and directed.
M&L Brick work with fly ash bricks straight or curved on plan exc. 6 m mean radius built in CM(1:6) complete all as specified and directed.
M&L for rendering 10 mm thick on brick work/ concrete surfaces in cement mortar 1:6 on fair faces finished fair & even complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work in CM 1:4 mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer instructions, surface finished even and fair without using extra cement complete all as specified and directed. (Note : Integral WPC shall be measured and paid seprately )
Supply only integral WPC ISI marked complete all as specified and directed.
Preparation of newly plastered surfaces and applying two coat of oil bound disemper over one coat of oil base primer over 2mm thick wall care putty on walls surfaces complete all as specified directed.
M&L for preparing newly plastered surfaces of walls and applying two coats weather coat emulsion over one coat cement base prime over 2 mm thick wall care putty complete all as specified and directed.
M & L for complete removal existing treatment and distempering on old walls and applying two coat of oil bound disemper over one coat of oil base primer over 2mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment and distempering on old walls and applying two coats of weather coat emulsion paint white or tinted over a coat primer over 2mm thick wall care putty complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 50mm thick PCC 1:3:6, type C-1, using 20mm graded stone aggregate as in plinth protection, laid in slope in 1:30 in pannels n. exc. 2m long, concrete surfaces finished even and smooth without using extra cement including making joints between panel to panel and filling the same with bitumen mastic using bitumen and sand mixture in a ratio of 1:3 complete all as specified and directed.
Taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. to match with the existing good surfaces of walls, floors etc. complete all as specified and directed.
M&L for point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly complete all as specified.
The same as above item No 40 hereinbefore but for socket outlet point 5 amps on independent board.
The same as above item No 40 hereinbefore but one socket outlet point on same baord.
M&L point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sqmm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly complete all as specified and directed.
S&F in repair polycarbonate switch piano flush type, SP,5/6 Amps, complete all as specified and directed.
S&F in repair polycarbonate switch piano flush type, SP, 16/20 Amps, one way complete all as specified and directed.
S&F in repair polycarbonate socket out let 2 in 1 socket 5 pin, (6 Amps) flush type controlled by one switch, complete all as specified and directed.
S&F Polycarbonate socket out let 6 pin, 20 Amps ISI Marked 20 Amps 240 Volts flush type, make complete all as specified.
S&F in repair ceiling rose, 3 Phase 6A, complete all as specified and directed.
S&F Indian standard fan regulator step type, 100 watt, complete all as specified and directed.
S&F in repair epoxy powder coated distribution box SPN 8 way, 240 Volts for MCBs, grouted flush to walls with IP 43 protection and metal double door all complete all as specified and directed.
S&F in repair MCB,SP,20 to 32 Amps, 240 Volts to be housed in DBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCBs are deemed to be ncluded in the unit rate)
The same as item No 51 above but MCB, SPN 32 to 40 Amps, 240 Volts.
M&L in repair for sub main wiring comprising with two single core,4 Sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated FRLS Grade unsheathed 1100 Volts grade drawing in PVC conduits and conduit fittings complete (concealed type) including 4 Sqmm nominal cross sectional area on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed (Cutting chases and making good of disturbed surfaces shall be deemed to be including in the unit rate quoted by tenderer). (Note :- Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for the same shall be deemed to be included)
M&L in repair for concealed sub main wiring comprising with two single core, 10 Sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated FRLS grade unsheathed 1100 Volts grade drawing in PVC conduits and conduit fittings complete (concealed type) including 10 Sqmm nominal cross sectional area stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.(Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tenderer). (Note :- Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for the same shall be deemed to be included)
M&L in repair earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly into ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate not less than 1.50 m below ground level, connected to GI lead wire of 4 mm dia. (7.50 m long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 1.5 mm nominal bore (7.50 m Long) for earth wire, watering pipe light grade of 20 mm nominal bore, 0.63 mm thick CI funnel, wire mesh etc complete including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 using 20 mm graded stone aggregate in earth pit and Precast RCC cover 50 mm thick dully reinforced with 6 mm dia, MS round bars @ 100 mm C/C both ways, earth testing point, making good to floor complete all as specified and directed.
S&F in repair plug and socket DBs with and including single pole MCBs rated 20 Amps capacity complete all as specified and directed.
S&F in repair distribution board TPN with and including of DPX MCCB 35 KA 160 Amps MCCB, FP, as incomer and SP/TPN MCBs as outgoing protection class IP 54, 8 way (DPX 160+24) with metal door double door complete all as specified and directed. Note :- FP, MCCBs 35 KA 160 Amps1 No and 24 Nos MCB, SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this this item )
Supply and fixing inrepair of recess LED llight fittings of size 2X2, 42 watt LED made of CRCA powder coated finish with fully covered by PMMA acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in false ceiling, electrical connection up to 15 feet height of various ward and dept complete all as specified and directed.
Supply and fixing in repair of recess LED llight fittings of round shape 10 watt, LED made of CRCA powder coated finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in false ceiling, electrical connection up to 15 feet height of various ward and dept complete all as specified and directed.
Supply and fixing in repair flexible copper cable three core suitable for connection of light fittings/ FTL fittings of any type complete all as specified and directed.
S & F in repair lamp holder batten/angular type , PVC/polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed.
Supply & fixing in repair ceiling fan 1200 mm sweep AC 230 volts single phase 5 star rated including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and directed. (Note: Old ceiling fan will be deposited in MES store yard.)
Supply & fixing in repair Metal Body exhaust fan 300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and directed. (Note:Old ceiling fan will be deposited in MES store yard.)
Supply & fixing in repair Metal Body exhaust fan 450 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and directed. (Note:Old ceiling fan will be deposited in MES store yard.)
Supply, fixing, connecting and testing in repair energy efficient LED flood light fittings of 160/170 Watt pressure die cast aluminium housing and IP 66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
Supply, fixing, connecting and testing in repair energy saving LED street light fittings of 60 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP 66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and fixing in repair Integral LED post top lanterns fitting black ABS plastic spigot, spun aluminium canopy, with opal diffuser and accessories suitable for 1x25 W CFL including making connections complete all as specified and directed.
Supply and fixing in repair SPN DB, 2 way without bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around the cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be measured for payment purpose.
M&L laying well burnt old size sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of bricks, laid dry over electric cable for protection of cable complete all as specified and directed.
Boring/Drilling (horizontally) manually under existing road (maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
Supply, laying, jointing and testing in repair LT under ground electric power cable crossed plyethylene (XLPE) 95 Sqmm 3.5 core insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade laid in trenches/ laid under floor or fixed naked with maked walls / on ples / in ducts /in GI pipes etc. complete all as specified and directed. Note: (Excavation, earth work, sand cushioning, protection of bricks/tiles/block, clamps, nuts, bolts, washers and pipe shall be measured and paid separately under appropriate items).
The same as item No 75 above but of size 10 sqmm 2 core nominal cross sectional area.
Supply and fixing in repairs galvanised mild steel pipe /tubing, light grade 40 mm bore complete with alll fittings, laid in trenches. Under roads, drain, paths, fixed to poles/walls with mild steel clamps, bolts nuts and washers complete all as specified and directed.
Supply fixing testing and commissioning of LT panel board for sub station of size 1.5 x 1.0 x 0.50 metre out door type factory made pedastal type fabricated out of 3 mm CRCA sheet and inner sheet of MS black sheet and slopy roof and spray painting two coat inside and outside with synthetic enamle paint of approved shade over a coat of red oxide primer and locking arrangement comprises of 50 mm size godrej brass pad lock with duplicate keys, two earth terminal suitable cable gland for all incoming and outgoing cable grouting of feeder piller box 40 cm above ground level by providing 90 cm long angle iron of size 50x50x6 mm welded on all the four corner embeded in PCC 1:2:4 type B1 using 20 mm graded stone agregrate up to 50 cm deep including connection of all exisiting cable with MCCB terminal complete all as specified and directed with and including the following components:-
Supply, fixing, connecting and testing in repair energy efficient LED bolard light of 18 Watt including foundation work in PCC 1:4:8 type D2 using 40 mm graded stone aggregate complete all as specified and directed.
Taking down old unserviceable FTL rod of any watt and Supply and fixing LED tube light Rod 18/20 watt 4 feet retro type complete all as specified and directed.
Taking down old unserviceable FTL batten and S& F new batten fiting suitable for LED tube rod 18/ 20 watt pre wired including connection complete all as specified and directed.
m/s raghubar dayal
M/s Reliable Electromech Systems
M/s Vimal Traders
chandra kaushal supplier
NEW BHARAT ENGINEERING AND CONSTRUCTION CO
M/s SNS Construction
M/S AMARJIT SINGH
ANIL CONSTRUCTION
PUMA POWER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .