Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAdmitted-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L1 | Admitted-Finance | |
| 2 | L2₹2.8 L+₹6,870.84 (2.50%)Admitted-Finance ADAM KANAN JHARGRAM 721507 | JHARGRAM | WEST BENGAL | 721507 | L2 | Admitted-Finance | |
| 3 | L3₹2.8 L+₹7,420.47 (2.70%)Admitted-Finance HATIARA SHARIF ROAD P O HATIARA KOLKATA 700157 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700157 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DEY ENTERPRISE L1 | GLACIER ENGINEERING CO L3 | DEBJYOTI BASU L2 |
|---|---|---|---|---|---|---|
| 1.00 | Charges for dismentaling the foundation of existing damaged voltage stabiliser after disconnection of power supply as per direction of EIC | 1 | No | 1,500 ₹1,500 Lowest | 1,540.5 ₹1,540.5 | 1,537.5 ₹1,537.5 |
| 1.01Supply and delivery at site of 20 KVA 3 phase, Oil cooled type servo motor operated copper wound line voltage corrector conforming to IS-9815 (Pt-)- 1994 suitable for unbalanced input voltage with following specification including first filling of oil as per IS-335 where applicable. [Make: Approved make of P.H.E. Dte.] [Rate is inclusive of Riverrine Charge @ 5%] | ||||||
| 1.02a) Input voltage:- 3 phase main supply may or may not be balanced with respect phase to phase 200V-500V phase to neutral 115V-289V b) Output voltage: 3 phase balanced output voltage. Phase to Phase 400V 0r 415V ± 1% Phase to Neutral 230V or 240V ± 1% [provision should be made to adjust the variation of output voltage per phase by a variable pot well within ± 5% of output] c) Line Regulation: Output voltage should remain well within ± 1% of set voltage [from min to max i.e. either 400V or 415V supply variation] d) Load Regulation: Output voltage should remain neutral well ± 1% of set voltage be (from no load to full load] i.e. either 400V or 415V supply variation) e) Correction speed: Better than 35 Volts second f) Efficiency: Better than 95% on full load g) Cut off limit for [minimum & maximum] by limit switch with audio & visual. h) Metering indication: By selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available. | ||||||
| 1.03 | i) Lamp indication: For input and output should be provided [ 3 lamp per side]
j) MCCB protection: For input side.
k) Load protection: HRC fuse on each output phase should be available.
l) Output over shoot: Beyond 210V to 255 volt/phase in case of "MANUAL MODE" and voltage protection "AUTO MODE" operation.
m) VISUAL indication for under voltage over voltage of output.
n) Manual mode: Up & Down correction with O/P voltage over shoot protection beyond 210V-255Volts per phase
o) Nature of cooling: Oil cooled system
p) Electric current over load protection
q) Circuit for delay outputr) Input high voltage cut off above 470 volt
s) Mode of Operation: AUTO/ MANUAL with a provision to restore the normal working of the unit " STANDBY OPERATION" should be available in case of any Electronic failure in auto mode
t) Auto Mode: Normal / Standby. (Manufacturing test certificate should be provided at the time of delivery). | 1 | Set | 2,00,040 ₹2,00,040 Lowest | 2,05,441.08 ₹2,05,441.08 | 2,05,041 ₹2,05,041 |
| 2.00Supply and delivery of following materials: | ||||||
| 2.01 | 63 Amps 4 pole on load change over switch [Make: Approved make of P.H.E. Dte.] | 1 | No | 9,600 ₹9,600 Lowest | 9,859.2 ₹9,859.2 | 9,840 ₹9,840 |
| 2.02 | 63 Amps Rewirable type TPN main switch [Make: Approved make of P.H.E. Dte.] | 1 | No | 6,810 ₹6,810 Lowest | 6,993.87 ₹6,993.87 | 6,980.25 ₹6,980.25 |
| 2.03 | 63 Amps 4 way Copper busbar chamber box by 16 SWG Sheet steel enclosure including poecelain chair etc. with painting complete as per direction of the EIC [Make: Approved make of P.H.E. Dte.] | 1 | No | 11,730 ₹11,730 Lowest | 12,046.71 ₹12,046.71 | 12,023.25 ₹12,023.25 |
| 2.04 | 25 sq. mm. 3.5 core 1.1 KV grade XLPE insulated Al. Ar. Cable as per IS:7098 (Part-II) 1988 with latest amendments [Make: Approved make of P.H.E. Dte.] | 40 | mtr | 695 ₹27,800 Lowest | 713.77 ₹28,550.8 | 712.38 ₹28,495.2 |
| 3.00 | Making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by (4:1) cement mortar including down foundation bolts (if required) and plaster with neat cement finish as per direction of EIC. | 1 | Item | 2,000 ₹2,000 Lowest | 2,054 ₹2,054 | 2,050 ₹2,050 |
Tender Value
Refer Docs
EMD Value
₹6,800
Closing Date
29 Aug 2026, 2:00 pmClosed
Executive Engineer SMD PHE Dte
Chetla
Supply, delivery and installation of 20 KVA servo motor operated Copper wound line voltage stabilizer at PH-3, Zone-II of Gosaba Rajapu Water Supply Scheme under Gosaba Block under SMD, PHE Dte.
2026_PHED_1036370_17
WBPHE/EE/SMD/NIeT-19 of 2026-27
Open Tender
Electrical Work/ Equipment
Item Rate
60 days
Gosaba
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,800
28 Sept 2026
5 Aug 2026
31 Aug 2026
5 Aug 2026
29 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for dismentaling the foundation of existing damaged voltage stabiliser after disconnection of power supply as per direction of EIC | 1 | No | - | - |
| 1.01 | Supply and delivery at site of 20 KVA 3 phase, Oil cooled type servo motor operated copper wound line voltage corrector conforming to IS-9815 (Pt-)- 1994 suitable for unbalanced input voltage with following specification including first filling of oil as per IS-335 where applicable. [Make: Approved make of P.H.E. Dte.] [Rate is inclusive of Riverrine Charge @ 5%] | - | - | - | - |
| 1.02 | a) Input voltage:- 3 phase main supply may or may not be balanced with respect phase to phase 200V-500V phase to neutral 115V-289V
b) Output voltage: 3 phase balanced output voltage. Phase to Phase 400V 0r 415V ± 1% Phase to Neutral 230V or 240V ± 1% [provision should be made to adjust the variation of output voltage per phase by a variable pot well within ± 5% of output]
c) Line Regulation: Output voltage should remain well within ± 1% of set voltage [from min to max i.e. either 400V or 415V supply variation]
d) Load Regulation: Output voltage should remain neutral well ± 1% of set voltage be (from no load to full load] i.e. either 400V or 415V supply variation)
e) Correction speed: Better than 35 Volts second f) Efficiency: Better than 95% on full load
g) Cut off limit for [minimum & maximum] by limit switch with audio & visual.
h) Metering indication: By selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available. | - | - | - | - |
| 1.03 | i) Lamp indication: For input and output should be provided [ 3 lamp per side]
j) MCCB protection: For input side.
k) Load protection: HRC fuse on each output phase should be available.
l) Output over shoot: Beyond 210V to 255 volt/phase in case of "MANUAL MODE" and voltage protection "AUTO MODE" operation.
m) VISUAL indication for under voltage over voltage of output.
n) Manual mode: Up & Down correction with O/P voltage over shoot protection beyond 210V-255Volts per phase
o) Nature of cooling: Oil cooled system
p) Electric current over load protection
q) Circuit for delay outputr) Input high voltage cut off above 470 volt
s) Mode of Operation: AUTO/ MANUAL with a provision to restore the normal working of the unit " STANDBY OPERATION" should be available in case of any Electronic failure in auto mode
t) Auto Mode: Normal / Standby. (Manufacturing test certificate should be provided at the time of delivery). | 1 | Set | - | - |
| 2Supply and delivery of following materials: | |||||
| 2.01 | 63 Amps 4 pole on load change over switch [Make: Approved make of P.H.E. Dte.] | 1 | No | - | - |
| 2.02 | 63 Amps Rewirable type TPN main switch [Make: Approved make of P.H.E. Dte.] | 1 | No | - | - |
| 2.03 | 63 Amps 4 way Copper busbar chamber box by 16 SWG Sheet steel enclosure including poecelain chair etc. with painting complete as per direction of the EIC [Make: Approved make of P.H.E. Dte.] | 1 | No | - | - |
| 2.04 | 25 sq. mm. 3.5 core 1.1 KV grade XLPE insulated Al. Ar. Cable as per IS:7098 (Part-II) 1988 with latest amendments [Make: Approved make of P.H.E. Dte.] | 40 | mtr | - | - |
| 3 | Making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by (4:1) cement mortar including down foundation bolts (if required) and plaster with neat cement finish as per direction of EIC. | 1 | Item | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tendernotice_2.pdf
PDF • 0.25 MB
BOQ_2545963.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .