Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.1 LAccepted-AOC | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹19.6 L+₹1.3 L (7.00%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | 2 | Rejected-Finance Other than L1 | |
| 3 | 3₹22.9 L+₹4.6 L (25.2%)Rejected-Finance | 3 | Rejected-Finance Other than L1 | |
| 4 | 4₹23.7 L+₹5.3 L (29.1%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | 4 | Rejected-Finance Other than L1 | |
| 5 | 5₹24.0 L+₹5.7 L (31.1%)Rejected-Finance A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | 5 | Rejected-Finance Other than L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/MAINT OF LT UG CABLE, ACB PANELS, DC RECTIFIER AND CONNECTED ACCESSORIES IN TECH AREA UNDER GE (AF) TUGHLAKABAD
2024_MES_660277_1
GE/TKD-44/2024-25
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹0
₹86,000
Yes
11 Nov 2024
11 Jul 2024
14 Sept 2024
11 Jul 2024
12 Sept 2024
26 Jul 2024
Amount
M&L for under ground low tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed Note :- The rate quoted by the contractor shall include the rate for excavating the cable at the fault location & pinpoint the fault, repairing the cable using cable jointing kits and by adding extra LT cable if required at site for jointing the cables as before to the panel and testing complete all as earth work and necessary T&P etc.
M&L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set / Pole / feeder pillar lean concrete etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
S&F in replacement of cable route indicator made out of 15x15x6mm GI plate welded with 8 mm x 45cm long GI rod grouted in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the words 'HT cable' as directed with synthetic enamel paint of two coats over a coat of primer including excavation and earth work all as directed.
M&L for Replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for 60 to 400 KVA transformer of any make /type/capacity all as specified and directed by Engineer-in-Charge
M&L for Top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity complete all as specified and directed
M&L for Dehydrating breather assembly Aluminium/CI body of standard size filled with silica-gel for transformer of any capacity complete all as specified and directed
M&L for Temperature gauge circular dia type of standard size for transformer of any complete all as specified and directed
M&L in replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity all as specified and directed by Engineer-in-Charge
Taking out hanging doors from LT Panels/ DG set/HT VCB panel welding the doors in position by using new hinges and scrapping old surface and cleaning smoothly, removing all dust and rust and relace the door closure if required including preparation of surfaces with synthatic enameled grey paint by using spray gun machine and writing capacity and location with black synthetic enamel paint complete all as directed by Engineer-in-Charge.
Cutting removing the vegetation growth and surface dressing, trimming of branches of trees coming on the sub stn or all around the installation yard including two pole structure areas, around power house, substation (external only) to keep always installation clean and tidy including white wash at plinth/ foundation of transformer if required complete all as specified and as directed by engineer-in-charge.
S&Fing of Straight through joints (Heat Shrink Kits) for LT underground cable complete for Armoured ,PVC sheathed Aluminium conductor cables by excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth all as specified and as directed for the following sizes:-
3.5 core cable 16 to 35 Sq mm.
3.5 core cable 50 to 95 Sq mm
3.5 core cable 120 to 185 Sq mm
3.5 core cable 240 to 300 Sq mm
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure all as directed.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core. The fault located equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and as directed. Notes : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 5 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 02 hours duration. (ii) For the purpose of payment one unit of “each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch , irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints, jointing materials and cable required shall be measured and paid for separately.
M&L for painting of VCB panel any size of the panel including connected duct in the transformer room with synthatic enameled grey paint by using spray gun machine after removing all dust and rust. inside and out side and writing the location as per existing of paint with black synthetic enamel paint complete all as directed by Engineer-in-Charge.
M&L for cement concrete in foundations, filling and mass comcrete type D2 1:4:8 with 40 mm graded stone aggrigate for foundation of pole etc complete all as specified.
S&F in repair hot moulded FRP looping /Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock froof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified.
Dimantling and taking out Exhaust fan 230 volts 300 to 450mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of capacitor, replacement of gun metal bushes/ bearing and painting after completion of rewinding process complete all as specified and as directed.
M&L for painting of LT panel (in both side) any size of the panel including connected LT bus duct in the transformer room with synthatic enameled grey paint by using spray gun machine after removing all dust and rust. inside and out side and writing the location as per existing of paint with black synthetic enamel paint complete all as directed by Engineer-in-Charge.
S&Fing in replacement of LED Bulb two pin/thired type suitable for fixing in lamp holder of capacity 5 Watt.
M&L in replacement of Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizees Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed by Engr-in-charge
M&L for preparation of old painted steel surfaces or wire mess fencing around the out door transformer over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed by enginner-in-charge.
M&L for cutting of metallic road/ hard standing / hard rock/ wall up to a size not exceeding 20 cm width and not exceeding 90 cm depth for laying of protection pipe for cable including making good the disturbed road/ hard standing by providing PCC (1:2:4) type B1, 40mm grade crushed stone aggregate and block top with black bituminous upto existing surface including suitable size of GI pipe (if necessary) complete all as specified and as specified and as directed by Enginner-in-Charge. Note:1. If damage / broken the inter locking tiles while removing the contractor shall replace the broken tiles with new one. 2. The Quoted rate is included for all material can paid/measured separately. 3. All the removable inter locking tiles/re fixable material shall kept carefully at a safe place for refixing with quoted rate.
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
M&L for dry clean river sand for cushioning in trenches for protection of under ground cable including watering and consolidation.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete as sepecified.
Supply and Layingl in replacement of cable XLPE insulated screened PVC bedded, galavanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes :-
300 sqmm 3.5 core.
240sqmm 3.5 core.
185 sqmm 3.5 core.
120 sqmm 3.5 core.
95 sqmm 3.5 core.
70 sqmm 3.5 core.
50 sqmm 3.5 core.
35 sqmm 3.5 core.
25 sqmm 4 core.
16 sqmm 4 core.
10 Sqmm 2 core
Supply & Fixing in replacement MCCB 630 Amps 3 Pole breaking capacity 50 kA,415 V,ICS=100 % of ICU Adjustable type suitable for existing LT panel.
Supply & Fixing in replacement MCCB 630 Amps 4 Pole breaking capasity 50 kA,415 V,ICS=100 % of ICU Adjustable suitable for existing LT panel type
Supply & Fixing in replacement MCCB 400 Amps 4 Pole breaking capacity 36 kA,415 V,suitable for existing LT panel Adjustable type ICS=100 % of ICU
S&F l in replacement of MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 125Amp, breaking capacity 25 kA complete suitable for existing LT panel all as speficied and directed by Engr-in-charge .ICS=100 % of ICU
S&Fl in replacement of MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 100Amp, breaking capacity 25 kA complete suitable for existing LT panel all as speficied and directed by Engr-in-charge .ICS=100 % of ICU
S&F l in replacement of MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 200Amp, breaking capacity 36 kA complete suitable for existing LT panel all as speficied and directed by Engr-in-charge .ICS=100 % of ICU
S&F l in replacement of MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 250Amp, breaking capacity 25 kA complete suitable for existing LT panel all as speficied and directed by Engr-in-charge ICS=100 % of ICU .
S&F l in replacement of MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 63 Amp, breaking capacity 36 kA complete suitable for existing LT panel all as speficied and directed by Engr-in-charge ICS=100 % of ICU .
S&Fing l in replacement of Automatic transfer switch of capacity 400 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge.
S&Fingl in replacement of Automatic transfer switch of capacity 200 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge.
S&Fing l in replacement of street light panel 3 phase , frame size 1 , complete including mounted on Angle iron stand of size 50x50x6mm having minimum height 1.5 feet duly grouted on ground complete all as specified and as directed by Engr-in-charge.
S&Fingl in replacement of analog type voltmeter of range 0-500 Volts single phase, Class 01 of size 96 x 96mm suitable for existing LT panel.
S&Fing l in replacement of analog type amp meter with CTs 0-300 Amps single phase, class 01 of size 96 X 96mm suitable for existing LT panel.
S&Fing HRC fuse link RH type of capacity 63 Amp 415volt,
S&Fing HRC fuse link DIN type of rating 250 Amp 415volt,
Supply, installing,in replacement, testing and commissioning factory made and tested LT Panelout door type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 3.15.mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm Aluminium, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- Make:- Havells/ Schneider / ABB/ L&T/ Universal Switch Gear Control/SMS/National BUS BAR CHAMBER :- (a) 400 Amp 3 Strips & Neutral Strip 200 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
S&F in repair of 3 pole power contactor MNX 325 2 NO + 2 NC of AC rating 325 Amps & AC rating 400 amps.
S&F in replacement of old deteriorated aluminium tube terminals with new aluminium tube terminals for HT cable (heavy duty thimble) of size 95 sqmm to 120 sqmm including suitable size nuts, bolts & washers complete all as specified and directed.
S&F in replacement of old deteriorated aluminium tube terminals with new aluminium tube terminals for HT cable (heavy duty thimble) of size 150 sqmm to 185 sqmm including suitable size nuts, bolts & washers complete all as specified and directed.
S&F in replacement of old deteriorated aluminium tube terminals with new aluminium tube terminals for HT cable (heavy duty thimble) of size 240 sqmm to 300 sqmm including suitable size nuts, bolts & washers complete all as specified and directed.
Supply, fix cable jointing kit and testing complete for 11 kv grade cable for Indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm to 185 sqmm excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth all as specified and directed.
All as per item No 53 above but of size 240 sqmm to 300 sqmm complete all as specified and directed.
All as per item No 53 above but of size 50 sqmm to 95 sqmm complete all as specified and directed.
S&F in replacement Energy saving 150 Watt envoirmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light in LT polewith high power LEDs as light source, suitable for heighlighting architectural features completet with all electrical accessories all as specified by EIC
S&F in replacement, LED street light fitting of capacity 60 watt, cool white, complete with drivers and all accessories & making all necessary connection complete all as specified and directed
M&L in replacement of GI tubing 'Light' grade for cable protection fixed in poles/walls/laid under roads/crossing etc for following sizes and all as specified.
80mm bore
50mm bore
S&Fing in replacement Aluminium tube terminal of capacity 10 sqmm.to 50 sqmm.
S&Fing in replacement Aluminium tube terminal of capacity 70 sqmm. to120 sqmm.
S&Fing in replacement Aluminium tube terminal of capacity 150 sqmm. To 185 sqmm
S&Fing in replacement Aluminium tube terminal of capacity 240 sqmm. To 300 sqmm
M&L cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 50 to 95 Sqmm.
M&L cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm.
M&L cable jointing kit for 11 KV (earthed) grade cable for Straight through heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm.
M&L cable jointing kit for 11 KV (earthed) grade cable for Straight through heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 50 Sqmm to 95 Sqmm.
Supply and installingin replacement, testing and commissioning of indoor type panel factory made polycarbonate (optical clarity) (shock proof,rust free, corrosion free,dust proof, acid and chemical resistant,fire retardant, having high impact,made of halogen and silica free,recyclable material), UV resistant, having high grade gasket made of polyurethane,should withstand glow wire test at 650C should be flame retardant,the feeder pillar panel should be as per ERDA Certification with switchgear assemblies as per IEC 60 439-1.following tests performed and passed and satisfactory with Compartmentlized each MCCB & Bus bar in sperate enclosure: (1) Temperature Rise (2) Dielectric properties (3) short circuit withstand current Rate peak & shor time withstand current and Rated conditional short circuit current (4) Effectiveness of protective circuits. (5) Clearance & creep age distance. (6) Mechanical operation, mounted on angle iron frame of size 50mm X 50mm X 6mm thick Complete with necessary foundation work as directed at site. BUS BAR CHAMBER:- 1000 Amp TPN, Aluminium. conductor, Supported on insulated plate form,interconnection of all incomings & outgoings.
Supply & Fixing in replacement MCCB 1000 Amps 4 Pole breaking capasity 50 kA,415 V, alongwith spreader/link ICS=100 % of ICU Adjustable suitable for existing LT panel type
S&F in replacement of MCB TPN 4 pole 16 to 32 amp 415 volt,10 KA breaking capacity complete all as speciifed and directed.
S&F in replacement of MCB TPN 4 pole 40 to 63 amp 415 volt 10 KA breaking capacity complete all as speciifed and directed.
S&F in replacement of MCB SP 5A to 32 amp 240V,10KA breaking capacity complete all as speciifed and directed.
S&F in replacement of MCB SPN 32 amp 240V,10KA breaking capacity complete all as speciifed and directed.
Sumit Enterprises (BID ID -3081731)
M/s Prakash Enterprises (BID ID -3085415)
ANAND ENTERPRISES (BID ID -3093834)
Deepak Electricals (BID ID -3084886)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .