Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.1 L
Closing Date
29 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Electrification of First Floor, Office Complex Sheikh HamzaRA Guest House, at Naseem Bagh Campus.
2021_UDJK_120802_1
F(E.Tend)( UCD)KU/66/20
Open Tender
Electrical Works
Item Rate
30 days
Electrification of First Floor, Office Complex She
As per NIT
5 documents required · 5 mandatory
₹100
Yes
Registrar University of Kashmir
Exempted
30 Mar 2021
18 Mar 2021
30 Mar 2021
18 Mar 2021
29 Mar 2021
18 Mar 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable( (Finolex, Polycab make) in surface / recessed PVC conduit(D Plast, Tiger, PGC, Flair), with modular switch, modular socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC conduit included in above description for the follwing items (DSR 1.10.1) GROUP A( as Per NBC) From switch board to primary light point & it's loop point upto desired length.
Providing/ fixing of modular 16 Amp modular switches socket combined Box/recess type of ABB, Hager, Legrand, Havells (standard) make including modular plates etc. complete.
Providing/ fixing of modular 5 Amp switch, 5 Amp. 2 pin sockets, bell push, indicator of Legrand, ABB, Hager, Havells (standard) make including screws, etc. complete including modular plates etc. complete.
Providing/ fixing of modular 5 Amp. 3 pin sockets, bell push, indicator of Legrand, ABB, Hager, Havells (standard) make including screws, etc. including modular plates complete
Providing and fixing of PVC conduit of 1”, 2mm thick with assorted fitting of bends, tees, junction boxes, saddles, clamps wooden gut ties screws/Nails etc. (D plast/Tiger/PGC)
(DSR 1.25) Supplying and fixing stepped type electronic fan regulator(Legrand/Hager make) on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of AC 230/250 volts, 50 HZ energy efficient ceiling fan(C&G, USHA orKhaitan make) with standard down rod, blades, 2 nos. caps etc. Complete. 1200 mm sweep
Providing and Fixing of 9 Watts LED Panel, round/square type, color temp: 6500K/4000K, Surface/Recessed mounted as per site requirement of Philips or Havells or Wipro
Providing and Fixing of 15 Watts LED Panel, round/square type, Slim type color temp: 6500K/4000K, Surface/Recessed mounted as per site requirement of Philips or Havells or Wipro
Providing and fixing of 12”x12”shutter type exhaust fan complete with all accessories includindg Frame etc of Havells/ Halonix/ Anchor/Crompton make
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (DSR 1.7.10) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (Finolex, Havells, Polycab make).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR 1.14.4) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (Finolex, Havells, Polycab make).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy duty PVC conduit as required. Note : Rates of Suitable PVC conduit included in above description (DSR 1.14.1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (Finolex, Havells, Polycab make).
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR 2.3.3) 12 way , Double door Make: Legrands, Havells, ABB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2.10.1) Single pole Make: Legrand, Hager, ABB, Siemens
Providing and fixing of 2P 63 Amp, C-Curve MCB of make Legrand, Hager, ABB, Siemens.
Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2.10.3) Double pole Make: (Legrand, Hager, ABB, Siemens)
M/S WANI ELECTRIC AND MECHANICAL ENGINEERS
M/S MIR ELECTRICAL CONSTRUCTION and SUPPLIERS
HIBA ENGINEERING AND CONSTRUCTION WORKS
M/S WANI CONSTRUCTIONS
stage.html
html • 0.03 MB
finance_232455.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .