FACILITY DIRECTOR
OFFICE OF FACILITY DIRECTOR, BARCF, KALPAKKAM
MAINTENANCE OF ELECTRICAL POWER SYSTEMS HTand LT EQUIPMENTS AT NDDP MPDD 2022 and 2023
2023_BARC_737164_1
BARCF/NDDP/EI/TR/21/2022
Open Tender
Electrical Works
Item Rate
365 days
Kalpakkam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹54,081
10 Mar 2023
31 Jan 2023
16 Feb 2023
1 Feb 2023
10 Feb 2023
1 Feb 2023
1 Feb 2023 - 7 Feb 2023
Amount
Removal of Tube light fitting/CFL fitting from the ceiling/wall for complete wiring, testing and refixing to the original position (1/2x40W, 1/2x9/11/18W CFL)
Rectification of faults like earth fault, loose connections/contacts, changing of defective wires in 150/250W MV/SV fittings mounted on the perimeter wall of various buildings.
Rectification of faults like earth fault, loose connection / contacts, changing of defective wires or Replacement of accessories in fittings mounted in the high bay areas.
Rectification of faults like earth fault,loose connection / contacts, changing of defective wires or Replacement of accessories in street light fittings mounted in RCC poles
Maintenance of 4/6 way power and lighting distribution boards as per the scope of work and as directed by the Engineer-in-charge.
Maintenance of 8/12 way power and lighting distribution boards as per the scope of work and as directed by the Engineer-in-charge.
Maintenance of street light junction boxes mounted on the street light poles as per the scope of work and as directed by Engineer-in-charge.
Cleaning of external surfaces of tube light fittings / ceiling fans / wall mounting fans in its position without removal
Dismantling and painting of ceiling / pedestal / wall mounting / Exhaust fans (single phase) as per the scope of work and as directed by the Engineer-in-charge.
Overhauling and servicing of ceiling / pedestal / wall mounting / Exhaust fans (single phase) as per the scope of work and as directed by the Engineer-in-charge.
Attending complaints in various type of fans ceiling / Exhaust / Pedestal / Wall mounting etc. as per the scope of work.
Preventive maintenance check of single phase motors upto 2 H.P. rating as per the scope of work and as directed by the Engineer-in-charge.
Preventive maintenance checkof 3 phase motors upto 12.5 H.P. rating as per the scope of work and as directed by the Engineer-in-charge.
Preventive maintenance check of 3 phase motors upto 15 to 35 H.P. rating as per the scope of work and as directed by the Engineer-in-charge.
Preventive maintenance check of 3 phase motors upto 35 to 75 H.P. rating as per the scope of work and as directed by the Engineer-in-charge.
Preventive maintenance check of 3 phase motors of 375 H.P. rating as per the scope of work and as directed by the Engineer-in-charge.
Preventive maintenance check of 3 phase HT motors of 200/315 KW rating and 180 KVA Generator as per the scope of work and as directed by the Engineer-in-charge.
Greasing of various motors
Cleaning of single phase motors upto 2 H.P.
Cleaning of 3 phase motors upto 12.5 H.P.
Cleaning of 3 phase motors from 15 H.P to 35 H.P
Cleaning of 3 phase motors above 35 H.P to 75 H.P
Cleaning of 3 phase motors 375 H.P
Cleaning of H.T. Motors (200KW/315KW)/180 KVA Generator
Maintenance of SF units/Control gears of various equipments as per the scope of work and as directed by the Engineer-in-charge.
Maintenance of Push button station for 1 motor control as per the scope of work and as directed by the Engineer-in-charge.
Maintenance of Push button station for 6 motor control as per the scope of work and as directed by the Engineer-in-charge.
Cleaning of external surface of each vertical panel of power panels/control panels as per the scope of work and as directed by the Engineer-in-charge.
Maintenance of each vertical panel of power/control panels including cleaning, checking tightness of power and control terminations as per the scope of work and as directed by the Engineer-in-charge.
Maintenance of Vacuum / Air circuit breakers as per the scope of work and as directed by the Engineer-in-charge.
Maintenance of Lead-Acid type batteries as per the scope of work and as directed by the Engineer-in-charge per cell
Maintenance of VRLA type batteries as per the scope of work and as directed byt he Engineer-in-charge per cell
Cleaning of external surface of 2 MVA power transformer and Neutral Grounding Resistor panel
Cleaning of external surface of 250KVA power transformer.
Maintenance of 2 MVA power transformer & Neutral Grounding Resistor including cleaning, checking tightness of power terminations and as per the scope of work.
Maintenance of 250KVA power transformer including cleaning, checking tightness of power terminations and as per the scope of work.
Maintenance of earth pits as per the scope of work.
Maintenance of bus ducts in NDDP substation as per the scope of work and as directed by Engineer-in-charge.
Supply of Aluminium paint and apply: Cleaning the surface, painting two finish heat resistance aluminium paint suitable for 250 deg. Centrigrade Steam pipe lines , hot condensate tank and Hot vent lines. supply, transportation of paint and consumables like thinner, paint brushes, wire brushes, emery sheets, etc.,Note: Providing required Scaffolding for the purpose of the above work is in the scope of contractors.
Cleaning the surface, applying one coat of metal oxide primer and two coats of synthetic enamel paint. (Supply of paint and other materials is in contractor's scope)
Supply of 36W, 230V AC, 50 Hz, 4 feet tubular Flourescent lamp with 2450 lumens light output, colour temperature 6500K, cool day light as per IS 2418, Make: Philips/crompton/bajaj
Supply of four feet, 16/18W LED Tube light suitable for 230 volt, 50Hz AC supply. MAKE: CROMPTON, CAT REF NO:LTT8-16, BAJAJ Poduct code: 112432 type:BLRB 18W CWC
Supply of Insulation Tape (LT)
Supply of M.Seal
Supply of 12W LED street light fitting suitable for 230 Volt, 50Hz AC supply make: CROMPTON CAT REF NO:LSTP-12-CDL
Supply of 60 W LED street light fitting suitable for 230 volt, 50 Hz AC supply.Make: CROMPTON, CAT REF NO: LSTP-60-CDL
Supply of RCCB (30mA upto 63A)
supply of LED mounting rail with CRCA sheet steel Housing suitable for 2×18 watts, 4 feet, LED Tube light 230v, 50hz AC supply make: orient LIBT-218-DS or CROMPTON, CAT. REF. NO: IGP132LT8-16 .
Supply of 6 A One-way switches in the existing M.S. switch boxes with the same brand and specification
Supply of 16 A One-way switches in the existing M.S. switch boxes with the same brand and specification
Supply of 6A, 3 pin shuttered sockets in hte existing M.S. switch boxes with the same brand and specification
Supply of 16A, 3 pin combined shuttered sockets in the existing M.S. switch boxes with the same brand and specification
Supply of 25 Amps AC starter
Supply of protective wire mesh guard to replace in the wall mounting / pedestal fans as directed by the Engineer-in-charge.
Supply of 1 ph, 230V, 50Hz, 380 mm dia heavy duty industrial type exhaust fan. Make: Almonard or bajaj.
Supply of 1.5 Sqmm multistrand FRLSH wire
Supply of 2.5 Sqmm multistrand FRLSH wire
Supply of 4.0 Sqmm multistrand FRLSH wire
Supply of white waste bleached baniyan cloth 150mm width *250mm length
Supply of Rust disintegrator (Rustolene) for maintenance purpose
Supply of CRC 2-26 cleaning agent in disposable container of 500ml can for general purpose cleaning of electrical equipments
Supply of 22.5 mm dia LED indication lamp suitable for 230 volt, 50Hz AC/110 volt DC supply. Make : teknic, cat no:2PLBR
Supply of industrial grade silicagel for existing power Transformer
Supply and laying of 25×3 mm Tinned Copper earthing flat through wall, Floor, Built-in trenches including supply of clamps and fixing fasteners as per the detailed specification and as directed by Engineer-in-charge.
Supply and laying of 50×6 mm G.I earthing flat through wall, Floor, Built-in trenches including supply of clamps and fixing fasteners as per the detailed specification and as directed by Engineer-in-charge.
Supply and laying of 25×6 mm G.I earthing flat through wall, Floor, Built-in trenches including supply of clamps and fixing fasteners as per the detailed specification and as directed by Engineer-in-charge.
Supply and laying, termination, testing and commissioning of 95 Sq.mm stranded copper conductor through wall, Floor, Built-in trenches including supply of clamps and fixing fasteners as per the detailed specification and as directed by Engineer-in-charge.
Supply and laying of 8 SWG Copper earthing conductor through wall, Floor, Built-in trenches including supply of lugs and fixing fasteners as per the detailed specification and as directed by Engineer-in-charge
supply and installation of conventional type lightning arrester (MAKE: CYCLO OR Equivalent)suitable for 8 mtr high building with accessories like down rod, clamps, supporting brackets, hardwares and fixing the same as per standards and as required as per site conditions.
Supply and installation of Multi function Eletronic timers in various electrical feeders and equipment as directed by the Engineer-In-Carge.
Supply and installation of Electrical power supply extention board consist of 20Amps 2pole MCB 1 no as incomer, 10Amps,2pole MCB 4no as outgoing, 20 Amps metal clad socket 4 nos installed in Metal enclosure with 20 mtrs of 4 core 2.5 Sq.mm PVC flxible cable and 20Amps metal clad plug top for power connection Etc,.
supply and installation of 24 volt AC hand lamp with protective mesh guard and insulated handle with 20 mtrs of 3 core 1.5 Sq.mm pvc fluxible cable and Metal clad plug top.
Supply and installation of L&T or equivalent make MN2 Thermal over load relays of range upto 20-33 Amps in various electrical feeders and equipment as directed by the Engineer-In-Carge.
Supply and installation of L&T or equivalent make MN2 Thermal over load relays of range upto 30-50 Amps in various electrical feeders and equipment as directed by the Engineer-In-Carge.
Supply and installation of L&T or equivalent make ML2 32Amps power contactors in various electrical feeders and equipment as directed by the Engineer-In-Carge.
Supply and installation of L&T or equivalent make ML4 70 Amps power contactors in various electrical feeders and equipment as directed by the Engineer-In-Carge.
Supply and installation of RE300 Relay suitable for 110/220 V, AC/DC supplu in 11 KV VCB panels and equipment as directed by the Engineer-In-Carge.
Supply and replacement of trip coil suitable for 110 VDC supply in 11/6.6 KV VCB panels and equipment as directed by the Engineer-In-Carge.
Supply and replacement of closing coil suitable for 110 VDC supply in 11/6.6 KV VCB panels and equipment as directed by the Engineer-In-Carge.
Supply and replacement of Trip/Nutral/Close switch suitable for 11/6.6 KV VCB panel board as directed by the Engineer-In-Carge.
Supply and installation of moving coil/iron type ammeter suitabl for CT secondery current of 5A and size up to 144 Sq.mm in various electrical feeders and equipment as directed by the Engineer-In-Carge.
Supply and installation of moving coil/iron type voltmeter Range :0-500 VAC, size up to 144 Sq.mm in various electrical feeders and equipment as directed by the Engineer-In-Carge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .