Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | ₹12.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹12.6 LRejected-AOC | ₹12.6 L | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Contractor Refuse to Do Work Due Tp Personal Reasons |
Tender Value
₹12.7 L
EMD Value
₹25,420
Closing Date
9 Jan 2026, 12:00 pmClosed
Executive Engineer
Vikash Bhawan
Kasturba Gandhi Awasiya Balika Jungle Village Campierganj Gorakhpur mein Marammat Karya
2025_REDUP_1101126_5
2318/EE/RED/GKP/25-26 Date 08/12/25
Open Tender
Civil Works
90 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹812
₹25,420
25 Mar 2026
3 Jan 2026
10 Jan 2026
3 Jan 2026
9 Jan 2026
3 Jan 2026
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm. D.S.R. 11.46.2
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Acrylic smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67ltr/10 sqm over the including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections Powder coated aluminium (minimum thickness of powder coating 50 micron) D.S.R. 21.1.1.2
As per item no. above but for shutter of window and ventilator Powder coated aluminium (minimum thickness of powder coating 50 micron) D.S.R. 21.1.2.2
Providing and fixing glazing in aluminium door, window, ventilator shutters D.S.R. 21.3.2
Providing and fixing aluminium handles, (125 mm) D.S.R. No. 9.100.1
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (250x10mm) D.S.R. No. 9.97.2
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used (a) With G.I. barbed wire
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Tendernotice_2.pdf
PDF • 0.61 MB
BOQ_2029457.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid