Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | ₹1.6 Cr Quoted ₹1.7 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.9 Cr+₹22.5 L (13.4%)Rejected-Finance HOUSE NO 165 A VILLAGE POST MORTA DISTT GHAZIABAD U P PIN 201003 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201003 | ₹1.9 Cr+₹22.5 L (13.4%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹1.9 Cr+₹24.7 L (14.7%)Rejected-Finance | ₹1.9 Cr+₹24.7 L (14.7%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹2.0 Cr+₹37.2 L (22.2%)Rejected-Finance | ₹2.0 Cr+₹37.2 L (22.2%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹2.1 Cr+₹40.6 L (24.2%)Rejected-Finance 0 00 NEAR KRISHNA PETROL PUMP GEEDAM ROAD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | ₹2.1 Cr+₹40.6 L (24.2%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
24 Nov 2023, 6:00 pmClosed
Col Laxmisha Suvarna
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
DEMOLITION AND RECONSTRUCTION OF BILLET NO P-313 AND IMPROVEMENT TO OTHER AIRMEN BILLETS AT 56 ASP FARIDABAD UNDER GE (AF) FARIDABAD
2023_MES_621374_1
CWE/GGN/FT-17/2023-24
Open Tender
Civil Works - Others
Lump-sum
450 days
AF Stn dabua
As per NIT
8 documents required · 8 mandatory
₹1,000
GE AF Faridabad
₹2.6 L
Yes
10 Jan 2024
3 Oct 2023
1 Dec 2023
3 Oct 2023
24 Nov 2023
11 Nov 2023
3 Oct 2023 - 24 Oct 2023
Amount
Sch 'A' Section I to IX under Srl No. 2.0 to 10.0 These schedules are pre-priced by MES. Details of section I to IX are given in Tender Documents
Lump sum price worked out by the contractor for 'Building Works' as listed in Sch 'A' Section-I (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'DEMOLITION OF BUILDING' as listed in Sch 'A' Section-II (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'EARTH WORK' as listed in Sch 'A' Section-III (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'IMPROVEMENT OF BUILDING' as listed in Sch 'A' Section-IV (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'ROAD PATH & CULVERT WORK' as listed in Sch 'A' Section-V (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'SEWAGE DISPOSAL' as listed in Sch 'A' Section-VI (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'AREA DRAINAGE' as listed in Sch 'A' Section-VII (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'FENCING AND COMPOUND WALL' as listed in Sch 'A' Section-VIII (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for 'INTERNAL ELECTRIFICATION' as listed in Sch 'A' Section-IX (refer prepriced shedule attached seperately)
MISCELLANEOUS ITEMS under Sch 'A' Section-X are not prepriced by MES and item Rate to be quoted by contractor for each item.
Taking down Old u/s Flushing Cistern complete all specified and directed.
M&L for Rubbing/Grinding and mirror polishing to the existing kota stone flooring including filling /pointing the joint with cement slurry mixed with pigment to match the surface complete all as specified and directed.
M&L for Temporary Arrangement to suppart the existing slab with hydrolic jack and scaffolding @0.5m spacing complete all as specified and as directed.
Demolition of existing roof treatment (incl pcc, plaster, brick tiles, mud etc) of any description and thickness upto roof top incl
M&L for two coat of aluminium paint over the roof (APP membrane) complete all as specified and directed.
M&L for Epoxy treatment for bonding new or old concrete surface with applying chemical fosroc and nitto Bond AR complete all as specified and directed and as per manufacturers instructions
S&F 15 mm bore ,UPVC high grade , including all fittings (like Elbow , Tee, Socket, Gi pipe connecter, nipples, tank connector etc) and fixing solutions/adhesive or chemicals and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed.
S&F 20 mm bore ,UPVC high grade , including all fittings (like Elbow , Tee, Socket, Gi pipe connecter, nipples, tank connector etc) and fixing solutions/adhesive or chemicals and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed.
S&F Windows made of Pre Painted Steel (Based on as per IS 513 On 0.58 MM Thick "D" quality galvanised as per IS 277 with Zinc coating of 120 GSM) Primer coated with epoxy primer of 5-7 micron thick, finished painted with a polymer paint of 12-16 micron thick and back coat with 5-7 microns thick alkyd backer section of outer frame should be 72X55 MM, centre mullion should be 72X5MM, section for fixed glass beading should be 12X12MM, and section of air tight shutter should be of 48X25MM with groove for gasket outter frame and mullion sections to have rebate for glazed shutter, fly mesh and 2 MM provisions for guard bars/ grills fly mesh shutter section should be of 2X4 MM. The section are to be cut to length mitre joined with corner bracket centre mullions to be fixed with mullion cap 2 nos handle of heavy duty SS pivot hinges shall be provided per shutter. The windows should be panelled with 4 MM thick plain float glass and SS mesh for fly mesh shutter (304 Grade). Rubber gasket are provided all around the glass. The above frames should be fixed to the concrete/ masonry wall by means of self expanding screws including 10 MM square guard bars with 6"(15 2.4MM) pitch complete all as specified and directed by Engg-in-Charge.
M&L for factory made box type steel section ventilators using ERW hollow section fixed type with forsted glazing bar@ 10mm Squre bar@ 10Cm C/C and with one shop coat of zinc xhomate primer complete all as specified & as directed.
S & F in repairs 20mm wide door seal aluminium powder coated fixed with screws on bottom rails of door shutters complete all as specified.
S&F in PTMT CP shower rose of size 100/125mm with arm including fixing to steel pipes complete all as specified and directed.
S&F in PVC waste pipe 800mm long suitable for 32mm dia waste coupling of plane PVC pipe (Not foldable type) of good quality sutable for WHB or urinal as directed by Engr in charge complete all as specified.
S&F in repair fancy stainless steel cloth hangers with minimum 04 hooks all as specified and directed.
M&L for Complete removal of existing treatment in old plastered walls including preparation of new or old plastered surfaces and applying two coats of weather proof emulsion (Apex Ultima) of electric blue or white colour over a coat of exterior wall care putty in (projections of column/wall/edges of chajja, roofs and other narrow locations in buildings upto ground plus three floor) all as specified and directed.
Supply and Fixing Bulding security light fitting 20 watt having uniformity ratio 0.25 high pressure die cast aluminium housing heat resistant toughned glass frame IP66 protection complete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grace 1.2 mtr long bent ti shape and fixed on wall with flat iron clamps, nut, bolts washer etc all as specified and directed.
Net Contract Sum will be after deducting Sch of Credit of Rs 3,09,632.00
NAVEEN KUMAR TYAGI
Adhunik Builders
M/s KUMAR BUILDERS
POOJA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .