GE ALWAR
GE ALWAR
REPAIR TO DAMAGED RCC MEMBERS ROOFS WALLS AND MISC CONNECTED WORKS UNDER AGE BR 1 AT ITARANA ALWAR
2021_MES_481787_1
8026/E8
Open Tender
Civil Works
Item Rate
210 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹30,000
Yes
9 Dec 2021
16 Oct 2021
15 Nov 2021
16 Oct 2021
13 Nov 2021
31 Oct 2021
16 Oct 2021 - 30 Oct 2021
60 days
Amount
Desilting and cleaning of earth/Mud saling on wall and floor for7.50m depth under ground sump and cleaning with clean water for further reparing and removing of all debries out sde the MD land complete all as spd and as directed by Eng-in-Charge
M&L for cleaning the surface ofRCC wall and floor surface with wire brush scraping loose cover of concrete detecting the sources of leakages for repairing complete all as spd and directed by Er-in-charge
M&L for driling 15mm holes into the RCC wall/Slab up to 75mm or D/2 as per site reqirementand fixing the mettalic packer of dia 10/12mm dia Aqua TP grouting Nipple and sealed as per manufacturers instruction all as spd and as directed by Engr in Charge
M&L for grouting of grouting material in Nipple/Metalic Packer using DR MIRACLEWAC @5kg/sqm of groutprepared by mixing DRMIRACLE WAC powder with waer as per manufacturer and 2% DRMIRACLE RETROMER (part-B) to make grout material and applying by grouting pump@5-7kg/sqCm pressure and as per manufacturer instruction complete all as spd and as directed by Engr-IN-Charge. These operations shall be doeby authorised applicator as approved by GE
M&L for driling 20mm holes into the RCC raftl/floor up to 75mm orD/2 as per site reqirementand fixing the mettalic packer ofdia19mm dia Aqua TP grouting Nipple and sealed as per manufacturers instruction all as spd and as directed by Engr in Charge
M&L for grouting by Three stages methodology for grouting by using DR MIRACLE SS/WAC/RTF powder mixed with water and add2% DR MIRACLERETROMER(Part-B) and grout the material@25kg/sqm materialby goutingpump @10to12 kg/sqCm pressure and as per manufacturer instruction complete all as spd and as directed by Engr-in-charge these operations shall bedone by authorised applicatpr as approved by GE.
Removing/Cuttingof Packers/nipple and making good in C:M 1:3 and level the wall and floor surface without damaging structural elements complete all as specified and as directed.
M&L for application of two coats of polymerized cementious water proofing coatby usingDR MIRACLE FLEX(2component)@4.0kg/sqm(1.50kgPolymer2.50kg DrMiraclePart-2) complete allas spd and asdirectedby Engr-in -Charge these operations shall be doneby authorised applicator as approvedby GE.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair face of brick work of walls, mixed with water proofing compound (ISI marked), finished even & smooth without using extra cement complete all as specified. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for taking down and removal of loose / disintegrated old concrete / plaster and applying 10mm thick bonding coat of modified styrene butadiene emulsion (SBR Bonding agent i.e. Nitobond SBR 45) in proportion 1 (Nitobond SBR 45) : 1(water) : 3 (OPC) by volume with the brushes etc to bind New Cement plaster/ polymer Modified plaster/ concrete/ screed concrete with old surface etc complete.
M&L applying 15mm thick plaster with polymer modified mortar fortified with SBR (Nitobond SBR 45 ) in proportion 1:3 by weight 5 litres Nit bond SBR 45 to added to 50 KG Cement with 13 litre water addition, finished surface to match with existing adjoining surface of ceiling, beams and alike complete.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia, complete, all as specified and directed.
All as per serial item No. 14.00 here-in-above but 8mm dia.
M&L and applying two or more coats of 2 component zinc based epoxy rust preventer (Nitozinc Primer-M) on corroded reinforcement after cleaning and removing the rust from corroded reinforcement with the help of wire brush and treating it with rust remover (Reebaklens RR) including thoroughly cleaning washing air blowing brushing etc complete Note : Qty of Zinc based epoxy rust prevent or only shall be taken into account for payment purpose on the basis of actual consumption.
M&L 12mm thick cement mortar plaster in 1:4 proportion (added with integral water proofing compound comp last X421 IC on the brick work / CC / RCC work or any other type of finish including removal of loose/disintegrated old concrete / plaster and surface preparation etc complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) all as specified & as directed.
M&L reinforced cement concrete (nominal mix) 1:2:4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete.
M&L for reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in chajjas and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in levelling course of floors and roofs 25mm thick finished fair & even complete all as specified & as directed.
Material and labour glazed ceramic tiles (coloured) Ist quality 350mm x 250mm x 7 mm , 450mm x 350mm x 7 mmthick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
Material and labour coloured non skid ceramic tiles 7 to 8mm thick Ist quality (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
Disconnecting & taking down the existing unserviceable water tank with ball valve and Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F as in repairs Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
M&L for 50mm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, not exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete.
M&L for precast RCC 1:2:4 type B1 using graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in kerb block with plain fair faces, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, complete, all as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing or removal to store.
Refixing old steel tubing and connection in new or old position (wall, ceiling, floor etc) of 15mm bore of pipe.
M&L galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store.
Refixing old steel tubing and connection in new or old position (wall, ceiling, floor etc) of 20mm bore of pipe.
M&L galvanised steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
Taking up or down 25mm bore steel tubing and connection incl cleaning for refixing or removal to store.
M&L galvanised steel water tubing medium grade of 25mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
S&F repairs sink made of stainless steel 1mm thick for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to dwarf wall, connecting union to pipe, overall minimum size 495mm x 420mm bowl size 410mm x 330mm x 160mm including 32mm dia waste pipe of polythelene of low or high density, 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete, all as specified and directed.
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified.
Supply and fixing as in repairs PVC valveless syphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified.
S&F in repairs vitreous china wash hand basin, colour, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified.
S&F in repairs pillar taps, (Swanneck type) cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot or cold' long screwed shanks and fly nuts, screwed for iron pipe and fixed bore of pipe in 15mm dia.
S&F as in repair 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F in repairs PVC connection 600 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
Material and labour 75 mm thick PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L factory made 60mm thick vibratory moulded precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as Specified & directed.
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified.
M&L for precast cement concrete (1:2:4 type B0 using 12.5mm graded crushed stone aggregate) louvers and jallies, 40mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:6 all as specified & as directed.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in pillar for fixing of jallies and setting in cement mortar 1:4, complete, all as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified & directed.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors and similar works of Gde E-165(Fe 290) including welding etc. complete all as specified & as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for in this Schedule all as specified & directed.
S&F vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified & as directed.
M/s S Amarjit Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .