Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹24.7 L+₹518 (0.02%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹24.7 L+₹1,318 (0.05%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹24.7 L+₹2,414 (0.10%)Rejected-Finance | L4 | Rejected-Finance 4th lowest | |
| 5 | Rejected-Technical G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | - | Rejected-Technical Reject |
Tender Value
Refer Docs
EMD Value
₹39,990
Closing Date
3 Jul 2024, 10:55 amClosed
Executive ENgineer, PWDte
Bankura
Electrical Repairing and Renovation works of Medical officers and staff Quarters at Sarenga BPHC.
2024_WBPWD_695652_1
WBPWDTE/EE/BED/NIQ_93/Q of 2023-24-2nd call tender
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
Sarenga BPHC
Please refer Tender documents.
3 documents required · 3 mandatory
₹39,990
30 Aug 2024
18 Jun 2024
5 Jul 2024
18 Jun 2024
3 Jul 2024
18 Jun 2024
Amount
PART-I -Doctor Qtr-5 Nos (Type-A) -2 Nos Dismentling the existing E.I. work incl existing defective , non functioning Panels , PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens ) as to GS 2+12 way Enclosure
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. 240 V, 32A DP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. 6A - 32A SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (RR Kabel / Havells /KEI / Polycabe or as per direction of EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] [E-15/5(d)] Average run 6 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS ' PVC insulated & unsheathed copper wire(Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board
Supply & Fixing 240 V, 2 x 6A, plug socket with separate (2 X 6 A) Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI/ Gloster/ Mescab )of following sizes in thick heavy gauge polythene pipe and necy. connection as required incl. cutting channel of (40mmx40mm)/(43mmx43mm)size on masonary wall with S&F heavy gauge 19mm/25mm dia 3mm thick polythene pipe by means of iron hooks and mending good damages to building works 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug )
2 x 4 sqmm + 1 x 2.5sqmm (for AC )
Supplying of following sizes Al. armoured PVC/XLPE Make-RR Kabel / Havells /Gloster or as per direction of EIC 2 core 10 sqmm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 2 core 10 sqmm
Supply & Delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork incld. safety wire of suitable gauge with out regulator, (Make- Usha (Striker plus One Star ) / Crompton Greaves (HS Plus 5 star) / Orient ( 5 Star ) and as per direction of EIC as per direction of EIC
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
S&F angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC
Supplying & Delivery 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Philips make cat No. TMC-502 1xTLED 22 W corresponding to Wipro / Crompton/Jaguar or as per direction of EIC
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm ) flexible copper wire of 1.10 mt. length.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supplying & Fixing 250 V Bulk Head Outdoor Light Fittings Model :WT202W LED6S NW PSU S2 PC Make-Phillips/ Wipro/Jaguar or as per direction of EIC.
Supply & Delivery 240 V,50 Hz, Metal body Heavy duty Exhaust fan of following sizes and RPM (Make -- EPC/ Calcutta Fans or any approved and recognised brand by EIC) 12" (30 cm), 1420 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following dia incld. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12" (30 cm)
S/F OLP - 30A A.C Starter suitable with G.I box flushed in wall with voltage check, Amp check, Time check incl. all connection.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying and fixing 240V, Sheet steel Main switch on flat iron/angle iron frame on wall with nuts bolts etc incl with fuse and L&N. 32A DP Make- L&T / ABB / Havells / Siemens
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts as per GS.
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
PART-II -Doctor Qtr- (Type-B) -7 Nos Dismentling the existing E.I. work incl existing defective , non functioning Panels , PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens ) as to GS 2+12 way Enclosure
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. 240 V, 32A DP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. 6A - 32A SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (RR Kabel / Havells /KEI / Polycabe or as per direction of EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] [E-15/5(d)] Average run 6 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS ' PVC insulated & unsheathed copper wire(Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board
Supply & Fixing 240 V, 2 x 6A, plug socket with separate (2 X 6 A) Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI/ Gloster/ Mescab )of following sizes in thick heavy gauge polythene pipe and necy. connection as required incl. cutting channel of (40mmx40mm)/(43mmx43mm)size on masonary wall with S&F heavy gauge 19mm/25mm dia 3mm thick polythene pipe by means of iron hooks and mending good damages to building works 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug )
2 x 4 sqmm + 1 x 2.5sqmm (for AC )
Supplying of following sizes Al. armoured PVC/XLPE (Havells/ Glostar /KEI/Polycab/ approved) as per direction of EIC 2 core 10 sqmm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 2 core 10 sqmm
Supply & Delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork incld. safety wire of suitable gauge with out regulator, (Make- Usha (Striker plus One Star ) / Crompton Greaves (HS Plus 5 star) Orient ( 5 Star ) and as per direction of EIC as per direction of EIC
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
S&F angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC
Supplying & Delivery 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Philips make cat No. TMC-502 1xTLED 22 W corresponding to Wipro / Crompton/Jaguar or as per direction of EIC
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm ) flexible copper wire of 1.10 mt. length.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supplying & Fixing 250 V Bulk Head Outdoor Light Fittings Model :WT202W LED6S NW PSU S2 PC Make-Phillips/ Wipro/Jaguar or as per direction of EIC.
Supply & Delivery 240 V,50 Hz, Metal body Heavy duty Exhaust fan of following sizes and RPM (Make -- EPC/ Calcutta Fans or any approved and recognised brand by EIC) 12" (30 cm), 1420 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following dia incld. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12" (30 cm), 920 RPM
S/F OLP - 30A A.C Starter suitable with G.I box flushed in wall with voltage check, Amp check, Time check incl. all connection.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying and fixing 240V, Sheet steel Main switch on flat iron/angle iron frame on wall with nuts bolts etc incl with fuse and L&N. 32A DP Make- L&T / ABB / Havells / Siemens
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts as per GS.
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
PART-III -Nurses Qtr-5 Nos Dismentling the existing E.I. work incl existing defective , non functioning Panels , PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens ) as to GS 2+12 way Enclosure
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. 240 V, 32A DP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. 6A - 32A SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (RR Kabel / Havells /KEI / Polycabe or as per direction of EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] [E-15/5(d)] Average run 6 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS ' PVC insulated & unsheathed copper wire(Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board
Supply & Fixing 240 V, 2 x 6A, plug socket with separate (2 X 6 A) Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI/ Gloster/ Mescab )of following sizes in thick heavy gauge polythene pipe and necy. connection as required incl. cutting channel of (40mmx40mm)/(43mmx43mm)size on masonary wall with S&F heavy gauge 19mm/25mm dia 3mm thick polythene pipe by means of iron hooks and mending good damages to building works 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug )
2 x 4 sqmm + 1 x 2.5sqmm (for AC )
Supplying of following sizes Al. armoured PVC/XLPE (Havells/ Glostar /KEI/Polycab/ approved) as per direction of EIC 2 core 10 sqmm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 2 core 10 sqmm
Supply & Delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork incld. safety wire of suitable gauge with out regulator, (Make- Usha (Striker plus One Star ) / Crompton Greaves (HS Plus 5 star) Orient ( 5 Star ) and as per direction of EIC as per direction of EIC
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
S&F angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC
Supplying & Delivery 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Philips make cat No. TMC-502 1xTLED 22 W corresponding to Wipro / Crompton/Jaguar or as per direction of EIC
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm ) flexible copper wire of 1.10 mt. length.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supplying & Fixing 250 V Bulk Head Outdoor Light Fittings Model :WT202W LED6S NW PSU S2 PC Make-Phillips/ Wipro/Jaguar or as per direction of EIC.
Supply & Delivery 240 V,50 Hz, Metal body Heavy duty Exhaust fan of following sizes and RPM (Make -- EPC/ Calcutta Fans or any approved and recognised brand by EIC) 12" (30 cm), 1420 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following dia incld. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12" (30 cm), 920 RPM
S/F OLP - 30A A.C Starter suitable with G.I box flushed in wall with voltage check, Amp check, Time check incl. all connection.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying and fixing 240V, Sheet steel Main switch on flat iron/angle iron frame on wall with nuts bolts etc incl with fuse and L&N. 32A DP Make- L&T / ABB / Havells / Siemens
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts as per GS.
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
PART-VI -Staff Qtr-16 Nos Dismentling the existing E.I. work incl existing defective , non functioning Panels , PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens ) as to GS 2+8 way Enclosure
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. 240 V, 32A DP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. 6A - 32A SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (RR Kabel / Havells /KEI / Polycabe or as per direction of EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] [E-15/5(d)] Average run 6 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS ' PVC insulated & unsheathed copper wire(Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board
Supply & Fixing 240 V, 2 x 6A, plug socket with separate (2 X 6 A) Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI/ Gloster/ Mescab )of following sizes in thick heavy gauge polythene pipe and necy. connection as required incl. cutting channel of (40mmx40mm)/(43mmx43mm)size on masonary wall with S&F heavy gauge 19mm/25mm dia 3mm thick polythene pipe by means of iron hooks and mending good damages to building works 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug )
2 x 4 sqmm + 1 x 2.5sqmm (for AC )
Supplying of following sizes Al. armoured PVC/XLPE (Havells/ Glostar /KEI/Polycab/ approved) as per direction of EIC 2 core 10 sqmm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 2 core 10 sqmm
Supply & Delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork incld. safety wire of suitable gauge with out regulator, (Make- Usha (Striker plus One Star ) / Crompton Greaves (HS Plus 5 star) Orient ( 5 Star ) and as per direction of EIC as per direction of EIC
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
S&F angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC
Supplying & Delivery 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Philips make cat No. TMC-502 1xTLED 22 W corresponding to Wipro / Crompton/Jaguar or as per direction of EIC
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm ) flexible copper wire of 1.10 mt. length.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supplying & Fixing 250 V Bulk Head Outdoor Light Fittings Model :WT202W LED6S NW PSU S2 PC Make-Phillips/ Wipro/Jaguar or as per direction of EIC.
Supply & Delivery 240 V,50 Hz, Metal body Heavy duty Exhaust fan of following sizes and RPM (Make -- EPC/ Calcutta Fans or any approved and recognised brand by EIC) 12" (30 cm), 1420 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following dia incld. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12" (30 cm), 1420 RPM
S/F OLP - 30A A.C Starter suitable with G.I box flushed in wall with voltage check, Amp check, Time check incl. all connection.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying and fixing 240V, Sheet steel Main switch on flat iron/angle iron frame on wall with nuts bolts etc incl with fuse and L&N. 32A DP Make- L&T / ABB / Havells / Siemens
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts as per GS.
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
UJJWAL MUKHERJEE
MANDAL TRADERS
Karmakar electrical Repairing Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .