Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Being (L1) | |
| 2 | L2₹32.4 L+₹7.3 L (29.1%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance Other than (L1) | |
| 3 | L3₹34.3 L+₹9.2 L (36.6%)Rejected-Finance | L3 | Rejected-Finance Other than (L1) | |
| 4 | L4₹36.2 L+₹11.2 L (44.5%)Rejected-Finance | L4 | Rejected-Finance Other than (L1) | |
| 5 | L5₹49.5 L+₹24.4 L (97.2%)Rejected-Finance | L5 | Rejected-Finance Other than (L1) |
Tender Value
₹39.4 L
EMD Value
₹78,800
Closing Date
27 Jul 2023, 6:00 pmClosed
GE (AF) E/M CHAKERI
GE(AF)EM Chakeri Kanpur
REPAIR MAINT OF LT PANEL AND ALLIED WORKS IN TECHNICAL AREA AT AFS KANPUR
2023_MES_604951_1
8624/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (AF) E/M CHAKERI
₹78,800
Yes
16 Sept 2023
22 Jun 2023
31 Jul 2023
22 Jun 2023
27 Jul 2023
7 Jul 2023
Amount
S & F in replacement of MCCB, thermal magnetic protection type of 630 Amps ,36 KA, 4 Pole, 415V fixed with and including lugs, nuts, bolts, washers, spacers, studs, links etc. testing and commissioning complete all as specified and directed.Make MCCB :- Legrand / L&T / ABB / C&S as approved by GE
All as per Item No. 1 above but MCCB of rating 400 Amps 36 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of rating 250 Amps 36 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of rating 200 Amps 36 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of rating 160 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of rating 125 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of rating 100 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of rating 63 Amps 25 KA, 4 Pole, 415V
M & L for cleaning and servicing of ACBs of any make with rating 630-1600 Amps, 50 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers, studs, links etc. testing and commissioning complete all as specified and directed. Note:- Measurement of ACB shall be made in MB as per its rating Amp)
All as per Item No. 9 above but of rating 2000 - 4000 Amps, 50/60/75 KA complete all as specified.
S & F in replacement of ACB , micro processor based draw out type, 3200 Amps ,75 KA, 4 Pole, 415V including including. lugs, nuts, bolts, washers, spacers, studs, links etc. testing and commissioning complete all as specified and directed. (Note:- Manufecturer's Serial number of ACB shall be recorded in MB). Make of ACB :- L&T / Legrand / ABB / Siemens / Schneider / C&S as approved by GE
All as per Item No. 11 above but ACB of rating 2000 Amps, 50KA.
All as per Item No. 11 above but ACB of rating 1600 Amps, 50KA.
All as per Item No. 11 above but ACB of rating 1250 Amps, 50KA
All as per Item No. 11 above but ACB of rating 800 Amps, 50KA.
All as per Item No. 11 above but ACB of rating 630 Amps, 50KA.
M & L in replacement for new steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws ,type 410 SP-31 ( 9 mtr height) complete including providing two coats of alumnium paint over a coat of red oxide primer and marking pole number with Black Paint as directed by Engineer in Charge all as specified and directed. Note: Excavation, earth work, concrete shall be measured & paid seperately
M & L for plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foundation , filling and mass concrete complete all as specified & directed by Engineer in Charge.
M & L for plain cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in coping of pole , finished fair and even complete all as specified & directed by Engineer in Charge.
Supply, installation, commissioning and testing out door type LT Panel of approved make , CPRI Approved, fabricated out of 3.15mm thick CRCA steel sheet powder coated , double door with and including MS angle iron (40x40x6mm) base frame , cubical type mounted, 3 phase, 4 wire, 415 volt properly insulated alumnium bus bars-04 Nos having 600 amp on Phase & Nuetral, dust and vermin proof, both side open with locking arrangement, danger board plate, fixed in position on plate form constructed with bric work in cm(1:4), rendered with 15mm thick cement plater in cm(1:6) complete all as specified and directed (Note:- Brick work and plaster shall be measred and paid seperetely under respective item here in before) by Engineer in Charge and comprising of following as under:- (a) INCOMMING:- (i) MCCB 400 Amp, 36KA, 415 Volt-01 No (b) OUTGOING:- (i) MCCB 250 Amp, 25KA, 415 Volt, 4P-01 No (ii) MCCB 125 Amp, 25KA, 415 Volt, 4P-01 No (iii) MCCB 100 Amp, 25KA, 415 Volt, 4P-01 No (iv) MCCB 63 Amp, 25KA, 415 Volt, 4P-02 Nos
S & F in replacement junction box (225 x 295 x 122 mm) comprising two / four Nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables, cable gland suitable for pole mounted outdoor type having IP-65 protection complete with FI clamp 40 x 4mm with nuts, bolts & washers including provision for inserting copper cable wires complete all as specified and directed. Make:-Sintex / Rittal / Hensel as approved by GE.
S & F in replacement of energy saving & enviroment friendly LED street light fittings made out of pressure die cast anodized alluminium housing having rating 60 watt with high efficiency polycarbonate UV stablized cover with integrated lens to ensure asymmetrical light and overall IP 65 protection complete all as specified and directed. Cat Part No. BRTFG 60W LED V3 WW of Bajaj or equivalent model in Philips / Havells / Wipro as approved by GE
All as per Item No. 22 above but of rating 90 wat complete, Cat Part No. BRTFG 90W LED I WW of Bajaj or equivalent model in Philips / Havells / Wipro as approved by GE.
S & F in replacement of rating 100-110 watt LED flood light with high luminus efficiency, protected to IP 65 with front toughened glass, with all necessary accessories required effective range including necessary mounting arrangement such as flat iron clamps, nuts, bolts & washers etc complete all as specified and directed. Cat Part No. BJFL 100W LED I of Bajaj or equivalent model in Philips / Havells / Wipro as approved by GE.
All as per Item No. 24 above but of rating 120 watt. Cat Part No. BJFL 120W LED I of Bajaj or equivalent model in Philips / Havells / Wipro as approved by GE.
S & F in replacement LED flare highbay of rating upto 150 watt light senergy saving, environment friendly & robust, IP 65 protected suitable for ceiling suspended type for better illumination and working environment complete all as specified and directed. Cat Part No. BGHBM 150W LED XE of Bajaj or equivalent model in Philips / Havells / Wipro as approved by GE.
Repair / Maintenance of LT Panel board by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete by means of CRC-226 / Petrol tightening of all joints in bus bar, checking of earth and neutral voltage, removal of foreign objects, replacement of u/s nuts / bolts / washers including replacement of corroded glands, lugs, thimbles, hinges, doors locks, door knobs, gaskets etc. and tightening them properly complete all as specified and directed.
Supply, installation, commissioning and testing out door type LT Panel of approved make , CPRI Approved, fabricated out of 3.15mm thick CRCA steel sheet powder coated , double door with and including MS angle iron (40x40x6mm) base frame , cubical type mounted, 3 phase, 4 wire, 415 volt properly insulated alumnium bus bars-04 Nos having 150 amp on Phase & Nuetral, dust and vermin proof, both side open with locking arrangement, danger board plate, fixed in position on plate form constructed with bric work in cm(1:4), rendered with 15mm thick cement plater in cm(1:6) complete all as specified and directed by Engineer in Charge (Note:- Brick work and plaster shall be measred and paid seperetely under respective item here in before) and comprising of following as under:- (a) INCOMMING:- (i) MCCB 100 Amp, 36KA, 415 Volt-01 No (b) OUTGOING:- (i) MCCB 63 Amp, 25KA, 415 Volt, 4P-04 Nos
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) all as specified and directed by Engineer in Charge.
M&L for rendering in cement mortar (1:6) on any type of brick work of concrete surface , finished fair and even and applying two coat of white wash on external / exposed surface complete all as specified and directed by Engineer in Charge.
S & F in replacement MCB SP 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. Make : Legrand / Indo Asian / L&T / Schneider / Havells
All as per Item No. 31 above but SPN of rating 16-32 Amps
All as per Item No. 31 above but TPN of rating 40-63 Amps
Repair & Maintenance of 60 - 90 watt LED street light / security light driver of existing make and size with suitable electronic circuit. The driver should be 140 V to 270 V universal driver with built in surge protection complete all as specified and directed.
All as per Item No. 34 above but 100 - 120 Watt.
M & L in replacement for earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6.3 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI strip 32 x 6 mm size as earthing lead , 40mm dia GI light grade watering pipe of suitable depth, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC (1:3:6) type C1, using 20mm graded stone aggregate alongwith lifting handle complete all as specified in electrcial plate no. 3 of SSR Part-I all as directed. (Note:-GI strip upto 7.5 m length in included in unit rate quoted by contractor).
M & L in replacement for earthing complete with Copper earth plate electrode of size 600 mm x 600 mm x 3.15 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to Copper strip 20 x 3 mm size as earthing lead filling around with chemical such as earth enhancing compound (MGSO4) including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to copper strip by means of Copper nuts, bolts and washers strip connected to earth plate including chamber PCC (1:3:6) type C1, using 20mm graded stone aggregate alongwith lifting handle complete all as specified in electrcial plate no. 3 of SSR Part-I all as directed. (Note:-Copper strip upto 7.5 m length in included in unit rate quoted by contractor).
M & L in replacement for Chemical earthing complete with Copper earth plate electrode of size 900 mm x 600 mm x 5 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to Copper strip 32 x 6 mm size as earthing lead filling around with chemical such as earth enhancing compound (MGSO4) including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to copper strip by means of Copper nuts, bolts and washers strip connected to earth plate including chamber PCC (1:3:6) type C1, using 20mm graded stone aggregate alongwith lifting handle complete all as specified in electrcial plate no. 3 of SSR Part-I all as directed. (Note:-Copper strip upto 7.5 m length in included in unit rate quoted by contractor).
M & L for removing old paint from the LT panels / Feeder Box / Pole by paint removers, cleaning by scrapping and preparing the surface and applying two coats of synthetic enameled paint of existing colour over a coat of red oxide primer and writing any description as required complete all as specified & directed. Note: Pole number in MB shall be recorded.
M & L for re-routing of LT cables off sizes from 10 Sqmm to 400 Sqmm, 2/3.5/4 core in ducts/wall/floor/roof/trusses etc incl. re-alignment, cutting/chassing in wall/duct and re-fixing as per site requirment, including replacement of luggs, nut, bolts, washers, saddle clamp etc, including making good the disturbed surface to match with the existing surface. complete all as specified and directed. Note: Initial and Rerouted Layout of cable after rerouting shall be sketched in MB.
M & L for detection of fault through fault locating high voltage mobile machine to locate the fault in underground cable by giving high voltage surge and to find out exact location of fault all as directed at site. (Note : The Item includes transportation, fuel charges, charging of machine etc. upto detecting fault at a time. Bidder must quote rate considering the fact that it is solely his responsibility to arrange fault locating machine & he should'nt expect facilitation from the dept. for the same.)
Taking out and reinstalling of LT switchgears / LT Panel / Pole / VCB / Transformer to a distance not more than 5 kms from power house / substation / any place and connecting incl. casting of suitable PCC foundation etc as per the site requirement complete all as specified and directed. (Note: Nature /Type of item shifted shall be entered in MB)
Attending breakdown attributable to cable faults or any of the connected transmission system & rectifying it in cable transmission line network upto end connections or any of electrical item connected therein during any hours of a day after receiving communication through Complaint Section / Concerned JE / Engr-in-charge either through teleponic call, text message, email or through messanger 24x7 hrs. Note:- The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 02 hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 10,000 /= per day shall be recovered from contractor's payment.
S & F in replacement of aluminium bus bar as per existing size, type and suitable for LT panel 415 Volt including insulator, taping / sleeving of bus bar and all accessories including nut, bolts, washers etc. complete all as specified and as directed.
Supply, laying, testing and commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5/4 core laid in trenches/duct/pole/wall etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed. Make :- Havells / Grandlay / Polycab / Gloster as approved by GE.
All as per Item No. 45 above but of size 16 sqmm 2/4 core.
Excavation in trenches by mechanical means, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
M & L for dry Ganga Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. (Note: Punned thickness shall be considerd for measurment purpose)
M & L for well burnt brick sub class B old size laying in trenches for cable protection with wight equal to length of brick complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
santosh electronics
S B ENTERPRISES
PAWAN COOL CORPORATION
M/s Sohanil Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .