| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.6 L+₹77,735 (2.44%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹41.2 L+₹9.4 L (29.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
3 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
Repair/Maint of Central Heating Plant installed at CESR A Engr Regt and MTF under AGE E/M-II of GE 865 EWS
2021_MES_465994_1
138WE/L-53/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹90,000
Yes
24 Sept 2021
6 Aug 2021
10 Sept 2021
6 Aug 2021
3 Sept 2021
20 Aug 2021
60 days
Amount
Dismantling of burner assembly of CHS and remvoing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 6.0 lakh Kilo cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakages found or any other repair required at site and reassembling/ testing the same, (4 Months after again service)complete all as specified and directed by Engr-in Charge.
S&F in sequence controller suitable for 6.0 lakh Kilo cal/hr with burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition rod suitable for 6.0 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition Transformer electronic type suitable for 6.0 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F temp controller digital type DTC 503 with sensor suitable for 6.0 lakh Kilo cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of photo cell as per existing suitable for 6.0 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of burner nozzle suitable for 6.0 lakh K/Cal/Hr complete all as specified and directed by Engr in charge.
S&F in replacement of Electrode suitable for burner of capacity 6.0 lakh Kilo cal/Hr complete all as specified and directed by Engr in charge.
Dismantling of burner assembly of CHS and remvoing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 3-4 lakh Kilo cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakages found or any other repair required at site and reassembling/ testing the same, (4 Months after again service)complete all as specified and directed by Engr-in Charge.
S&F in sequence controller suitable for 3-4 lakh Kilo cal/hr with burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition rod suitable for 3-4 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition Transformer electronic type suitable for 3-4 akh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F temp controller digital type DTC 503 with sensor suitable for 3-4 lakh Kilo cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of photo cell as per existing suitable for 3-4 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of burner nozzle suitable for 3-4 lakh Kilo cal/hr complete all as specified and directed by Engr in charge.
S&F in replacement of Electrode suitable for burner of capacity 3-4 lakh Kilo cal/hr complete all as specified and directed by Engr in charge.
Dismantling of burner assembly of CHS and remvoing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 1-2 lakh Kilo cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repir to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, (4 Months after again service)complete all as specified and directed by Engr-in Charge.
S&F in sequence controller suitable for 1-2 lakh Kilo cal/hr with burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition rod suitable for 1-2 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition Transformer electronic type suitable for 1-2 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F temp controller digital type DTC 503 with sensor suitable for 1-2 lakh Kilo cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of photo cell as per existing suitable for 1-2 lakh Kilo cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of burner nozzle suitable for 1-2 lakh Kilo cal/hr complete all as specified and directed by Engr in Charge.
S&F in replacement of Electrode suitable for burner of capacity 1-2 lakh Kilo cal/hr complete all as specified and directed by Engr in Charge.
S&F in replacement of pressure gauage 0 to 20 Kg/cm sq as per existing,complete all as specified and directed by Engineer-in-Charge.
S &F in replacement of Bridge rectifire 3-4 Lakh Kcal/Hr complete all as specified and directed by Engr in Charge.
S &F in replacement of hooter round type complete all as specified and directed by Engr in Charge.
S&F in replacement of thermostate assembly tail type as per existing suitable for 0 TO 30 degree centrigrade temprature, complete all as specified and directed by Engr in Charge.
M&L for repair of exaust pipe by welding, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of auto air pressure valve 3/8" as per existing, complete all as specified and directed by Engr in Charge.
S&F in replacement of High pressure fuel pipe 1.5 mtr as per existing,complete all as specified and directed by Engr in Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 7.5/10 HP with superior quality super enameled copper winding wire of appropriate size and gauge as per existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 5 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 3 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
M&L for servicing to the glycol pump and motor of capacity 7.5HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed by Engr in Charge.
M&L for servicing to the glycol pump and motor of capacity 5 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed by Engr in Charge.
M&L for servicing to the glycol pump and motor of capacity 3 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed by Engr in Charge.
M&L for servicing to the glycol pump and motor of capacity 2 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed by Engr in Charge.
M&L for servicing to the glycol pump and motor of capacity 1 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed by Engr in Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor single phase 240 volts of capacity 1-2 HP with superior quality super enameled copper winding wire of appropriate size and gauge as per existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
M & L for disconnecting all connection in existing panel board complete and re-fixing the same after removing the burnt lugs/thimbles complete including replacing the U/S MCCBS, Contactors, reley, bus bar indicator lamps etc., all as specified and as direcrted by Engr-in-Charge. Note- MCCBS, Contactors, reley, indicator lamps, S/Switchs, voltmeter, Ammeter are to be measured and paid seperately.
Supply and fix contactor type 3 TF 33, 415 volts complete all as specified and directed by Engr-in-Charge. Make- Siemens, L & T , Havells
Supply and fix contactor type ML 1.5, 220 volts, complete all as speified and directed by Engr-in-Charge. Make- Siemens, L & T , Havells
Supply and fix over load relay 8 to 12.5 Amps for contactor matching ser No 42 series 3 TF 33 complete all as specified and directed by Engr-in-Charge. Make- Siemens, L& T , Havells
Supply and fix over load relay 1.25 to 2 Amps for contactor matching ser No 43 series 3 TF 33 complete all as specified and directed by Engr-in-Charge. Make- Siemens, L& T , Havells
Supply and fix MCCB with current rating 160 Amps 415 V 4 Pole 36 KA with thermally adjustable complete all as specified and as directed by Engr-in-Charge.
Supply and fix MCCB with current rating 200 Amps 415 V 4 Pole 36 KA with thermally adjustable complete all as specified and as directed by Engr-in-Charge.
Supply and fix MCCB with current rating 100 Amps fixed type 415 V 3 Pole 16 KA complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of digital type volt meter 0-500 volts, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of digital type Amp meter complete with suitable CTs 0-300 Amps, complete all as specified and directed by Engr-in-Charge.
Supply and fix replacement of indicating lamps RYB as per existing complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and directed by Engr-in-Charge.
Supply fix in replacement of push button switch in RED or GREEN colours, 22mm dia as per existing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 6 sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 4 sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
Servicing & maint of AHU unit cap 26000 CFM including rectifiction of leakage if any found welding/bracing/ Greasing & oiling bearings, servicing of electric motors, removing of all Air filters & cleaning the same with air compresser and refixing in the same loction for smooth functioning & testing complete all as specified and directed by Engr in Charge.
M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size of 80 mm dia of pipe, complete all as specified and directed by Engr in Charge.
M & L for Insulation of M S Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size of 50 mm dia of pipe, complete all as specified and directed by Engr in Charge.
M&L for welding the leakage portion of MS pipe line including all T&P and materials required for welding the pipe line of size 25 mm to 200 mm including testing on full pressure complete all as specified and directed by Engr in Charge.
S&F in replacement of CI butter fly control valves of 65 mm bore as per existing, complete all as specified and directed by Engr in Charge.
S&F in replacement of CI butter fly control valves of 80 mm bore as per existing, complete all as specified and directed by Engr in Charge.
S&F in replacement of CI butter fly control valves of 50 mm bore as per existing, complete all as specified and directed by Engr in Charge.
S&F in replacement of CI butter fly control valves of 40mm bore as per existing, complete all as specified and directed by Engr in Charge.
M&L for Cleaning of MS diesel storage tanks (day to day tank) of capacity up to1000 ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with castic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank with two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L for Cleaning of MS diesel storage tanks of capacity up to10000 ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with castic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank with two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L for Cleaning of MS over head circulation tank of capacity 1000 ltrs of all type of T&P and chemical reqd for the same , including welding work to lekage surface including opeaning and refixing the existing insulating material to the external surface including painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 20 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 25 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 40 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 50 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 65 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 80 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 100 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
S&F in replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and directed by Engr in Charge.
S&F in replacement of FCU connection copper pipe 20/16 mm with check nut at both side as per reqd length, complete all as specified and directed by Engr in Charge.
Supply and fix switch socket combination of 5 Amp flush type complete all as specified and directed by Engr in Charge.
S&F in replacement of plug top 3 pin of capacity 5Amp complete all as specified and directed by Engr in Charge.
M&L for Electrical Control Wiring for FCU of any size including electronic display complete as per sample all as specified and directed by Engr in Charge.
M&L for attending of break down/day to day complaint or call on attending any break down or maint work in CHS located in 14 CESR, "A" Engr and MTF checking the serviceability of fan coil unit of any capacity for having continuous sreviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line any where about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge complete all as directed at site.
Dismantling the existing radiator unit of capacity from 3000 to 6500 K Cal per hour, taking it to nearest workshop cleaning the complete unit with coil shine chemical, detecting the leakage protion by applying nitrogen gas pressure, brazing the leakage protion, refixing the same unit from dismantled location including testing on load complete all as directed at site by Engineer-in- Charge.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leak proof of consisting of copper coils covered with aluminium finsing as per existing size of capacity 3000 K Cal / Hour including dismantling the existing unserviceable.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leak proof of consisting of copper coils covered with aluminium finsing as per existing size of capacity 4500 K Cal / Hour including dismantling the existing unserviceable.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leak proof of consisting of copper coils covered with aluminium finsing as per existing size of capacity 6000 K Cal / Hour including dismantling the existing unserviceable.
Supply and fix in replacement of needle valve 3/8 inch BSP as per existing complete all as specified and directed by Engr in Charge.
S&F in replacement of 'O' ring Clip of flexible pipe of existing size complete all as specified and directed by Engr in Charge.
Supply and fix Inlet/outlet forged brass ball valve 20 mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, including supply and fixing of GI nipple of size 3/4 inch including welding work cutting the existing rusty unserviceable MS/GI nipple complete including taking out existing unserviceable valve complete all as specified and directed.
Supply and fix Inlet/outlet forged brass ball valve 15 mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, including supply and fixing of GI nipple of size 3/4 inch including welding work cutting the existing rusty unserviceable MS/GI nipple complete including taking out existing unserviceable valve complete all as specified and directed.
M&L for Galvanised Iron Pipe Medium grade of size 25 mm dia complete with all fitting and fixed complete to walls and ceillings or laid in floors complete all as specified and directed by engr in Charge.
M&L for Galvanised Iron Pipe Medium grade of size 20 mm dia complete with all fitting and fixed complete to walls and ceillings or laid in floors complete all as specified and directed by engr in Charge.
M&L for Gun-metal, gate valves with iron wheel head ,screwed both ends for iron pipe and fixing of size 25 mm complete all as specified and directed by Engr in Charge.
M&L for Gun-metal, gate valves with iron wheel head ,screwed both ends for iron pipe and fixing of size 20 mm complete all as specified and directed by Engr in Charge.
M&L for Gun-metal, gate valves with iron wheel head ,screwed both ends for iron pipe and fixing of size 40 mm complete all as specified and directed by Engr in Charge.
M&L for Gun-metal, gate valves with iron wheel head ,screwed both ends for iron pipe and fixing of size 50 mm complete all as specified and directed by Engr in Charge.
S&F for closed cell elastometric insulation 30-40 Kg/Cum Mtr density 25 mm thick (Nitrile insulation) Complete all as specified and directed by Engr-in-Charge Make : Eurobatex/Superion/Aeorflex
S&F in replacement of Oil Pressure pump 7276-3D67A Complete all as specified and directed by Engr-in-Charge
S&F in Repair/Replacement of fan coil unit parts, duel shaft electric motor of capacity 30 Watt 930 RPM, 3 speed as per existing complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 40 mm dia complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 32 mm dia complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 25 mm dia complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 20 mm dia complete all as specified and directed by Engr-in-Charge
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundation , laying of pipes , cables etc. or for manholes pier holes poles not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard /dence soil complete all as specified and directed by engr in Charge.
Returning filling in soil including spreading levelling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr in Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading and levelling complete all as specified and directed by Engr in Charge.
S&F in replacement Temp controller regulator type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of lagging all around with 150mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 150 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
S&F in replacement of lagging all around with 100mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 100 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
S&F in replacement of lagging all around with 80mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 80 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
S&F in replacement of lagging all around with 65 mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 65 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor.
S&F in replacement of lagging all around with 50/40 mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 50/40 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
SUMEET TRADING CORPORATION
LOBZANG GURMET
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .