Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.0 Cr+₹60.1 L (42.4%)Rejected-Finance | ₹2.0 Cr+₹60.1 L (42.4%) | L2 | Rejected-Finance NOT THE LOWEST |
| 3 | L3₹2.2 Cr+₹77.0 L (54.4%)Rejected-Finance | ₹2.2 Cr+₹77.0 L (54.4%) | L3 | Rejected-Finance NOT THE LOWEST |
| 4 | L4₹2.2 Cr+₹82.0 L (57.9%)Rejected-Finance | ₹2.2 Cr+₹82.0 L (57.9%) | L4 | Rejected-Finance NOT THE LOWEST |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
21 Jan 2020, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF KLP ACCN (PHASE-I)AT CAATS NASIK
2019_MES_267805_3
84454E8
Open Tender
Civil Works
Lump-sum
365 days
NASIK
As per tender documents
6 documents required · 6 mandatory
₹1,000
GE NRC
₹2.0 L
10 Feb 2020
23 Dec 2019
22 Jan 2020
24 Dec 2019
21 Jan 2020
7 Jan 2020
24 Dec 2019 - 28 Dec 2019
Amount
NOTE: Schedule ‘A’ Part I (A), Part II (A), Part III(A), Part IV(A), Part V(A), Part VI to XI are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Lump sum price worked out by the contractor for Sch 'A' Part-I (A) (Building Works)
Lump sum price worked out by the contractor for Sch 'A' Part-II(A) (Internal Water Supply)
Lump sum price worked out by the contractor for Sch 'A' Part-III(A) (Internal Electrification)
Lump sum price worked out by the contractor for Sch 'A' Part-IV(A) (External Water Supply)
Lump sum price worked out by the contractor for Sch 'A' Part-V (A)(External Electrification)
Lump sum price worked out by the contractor for Sch 'A' Part-VI (Road,Path and Culvert)
Lump sum price worked out by the contractor for Sch 'A' Part-VII (Area Drainage)
Lump sum price worked out by the contractor for Sch 'A' Part-VIII (Sewage Disposal)
Lump sum price worked out by the contractor for Sch 'A' Part-IX (Lightning protection and aviation obstruction light)
Lump sum price worked out by the contractor forf Sch 'A' Part-X (Excavation & Earthwork)
SCHEDULE PART - I (B) (BUILDING WORKS- PARTLY COMPLETED BY THE DEFAULTING CONTRACTOR)
Construction & completion of left over work of building in double storey for single living accomodation for 13 Havs, 40 ORs and Dinning hall, cook house for 53 Hav/OR ( Single Storey) including sanitary annex block, connecting passage etc complete all as specified and shown on drawings. (Note: The details are shown in Annexure I to Sch ‘A’ Part-I (B) indicating yard stick & approx completed work respectively)
SCHEDULE PART - II (B) (INTERNAL WATER SUPPLY)
Supply, layiing , jointing CPVC( Chlorinated Polyvinyl Chloride) pipes with all CPVC fitting such as sockets, elbows, bends, tees reducers, unions, cap plugs, nipples, short pieces etc. jointing, cutting, de burring/beveling fitting preparation, applying primer, cleaner application on/inside pipe/fitting solvent cement application on pipe/ inside fittings andassembling the pipe fitting complete, all as per manufacturer's manual and fixed to wall by means of and including clips, wall hooks, etc laid on surface/floors or concealed in wall/floors all as specified and directed of following nominal sizes:-
(a) ½" size ( 15mm)
(b) ¾" size ( 20mm)
(c) 2" size ( 50mm)
SCHEDULE PART - III (B) (INTERNAL ELECTRIFICATION))
S & F exhaust fan, single phase, heavy duty, 450mm (18") sweep, 900/950RPM including fixing of mounting frame by means of rugged bolts, nuts and washers etc in the round hole cut in the wall including provision of louver shutter on outer surface of the wall and connecting with and including three core copper conductor flexible cord of 0.5Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed.
S & F Industrial F/T light fitting general purpose (Universal) mounting channel type housing and cover (reflector) fabricated from CRCA steel sheet stove enamelled in white inside and light dove grey outside, reflector in stove enamelled white suitable for 1x40/1x36 Watt F/tube, with heavy duty polyster filled vacuum pressure impregnated copper wound ballast, power factor improvement capacitor, bottle type starters with RF suppression capacitor, barrel type starter holder, spring loaded pushfit bipin rotor holders, all accessories prewired upto and including 2 way 5 Amp GFP main connector block, earthing terminal for earth wire complete luminaire suspended from ceiling/beam/tie beam by means of and including double stiff pendants comprising two pieces of 19mm dia black painted rigid steel conduit of required length, screwed both ends, stainless steel/chromium plated or anodised aluminium bell mouthed screwed back plates, fixed with ceiling /beam on PVC mounting blocks and other end of conduits fixed with luminaire with nuts, bolts and check nuts, connecting electrically by means of and including three core copper conductor flexible cord of 0.5Sqmm cross sectional area of required length, complete all as specified, directed and shown on drgs, luminaire make Crompton ISE 1414 HSB or Philips TKC 24/136 or Wipro WCF 26136.
Ditto all as per Serial Item No 5.02 above but fixed on walls/ceiling/beams etc on and including PVC mounting blocks without any suspension.
Ditto all as per Serial Item No 5.02 above but suitable for 1x18/1x20 watt fluoroscent tube fixed on walls /ceillings/beams etc on and including PVC mounting blocks without any suspension arrangement as per Wipro Cat Part No WCF 16120 or Crompton DML 12 LDB or Philips TMS 2005/120.
Ditto all as per Serial Item No 5.02 above but recessed mounting type MI mirror optics lumnaire suitable for 2x36/2x40watts F/tubes, suspended for RCC ceiling but fixed flush with false ceiling as per complete with suspension arrangement by means of and including two stiff pendants, mirror assy comprising of high purity aluminium reflector , serrated AL cross/louvers, complete all as specified and directed as per Philips TBS 305/236 MI or Wipro Cat Part No WCF 92240 or Crompton CRFA 24 HSB
S & F ( on external walls of the bldg) F/tube street light fittings suitable for 1x40 or 1x36 watt F/tube consisting of sheet aluminium canopy, reflector -cum control gear tray complete with all accessories like polyster resin filled copper ballast , starter, starter holder, spring loaded rotary type bipin holders, capacitor for power factor improvement all accessories prewired upto connector block, clear acrylic ribbed cover fixed with the frame with neoprene gasket and spring loaded double action toggle catches etc. including suitable mounting bracket of 32mm dia light grade GI pipe 1.5m long bent to shape, 2 Nos 25x3mm M.S.F.I. clamps of suitable size & shape, rugged bolts grouted in walls/columns, nuts, washers etc. and electrical connection with and including 3 core 0.5sqmm copper conductor PVC insulated and sheathed cable of required length from ceiling rose to connector block of the luminaire, complete all as specified and directed as per Philips HGS 120/136 HPF or Wipro Cat Part No WCF 15140 or Crompton SFE1414 LSB.
S & F bulk head light fitting, industrial type comprising of rugged gravity die-cast aluminium alloy LM-6 body in stove enamelled white inside and grey outside, fitted with heat resistance prismatic glass cover through a weather /dust proof heat resistance rubber gasket, two pin BC/EC porcelain lamp holder inside the housing, prewired upto 2 way 5 amp GEP mains connector, earthing terminal, suitable for 19mm ET cable entry through cable gland , MS Hot dipped/ electro galvanised wire guard, glass and wire guard assy hinged to the body with locking arrangement, complete luminaire suitable for in candesent lamp Make Wipro Cat Part No WKG 13 or Philips NXC 101 or or Crompton IBH 1110/ES. complete all as specified, directed and shown on drawing.
S & F (on external walls of the bldg) street light luminaire suitable for and including 1x150 watt HPSV lamp comprising of single piece deep drawn aluminium housing stove enamel hammertone grey finish outside, pre-anodised super high purity aluminium side reflector of wider distribution of light and high photonmetric effeciency , control gear housing fitted with heavy duty copper wound ballast, PF correction capacitor , 3 wire electronic ignitor, all accessories prewired upto 2 way 10A GFP mains connector inside the control gear compartment , GES (E-40) skirted porcelain lamp holder, earthing terminal hingable high transparency clear acrylic bowl cover fitted with antimoth and weather proof gasket to prevent ingress of insect/moisture, clamped to the canopy (lamps compartment) by means of anti corrosive stanless steel single action spring loaded complete luminaire conforming to IS-10332 part 5/Sec1: 1987, make crompton SSC 1207 AH/WI, Wipro WSS 20070 or Philips SRP 308/70(E) including suitable mounting bracket of 32mm dia light grade GI pipe 1.5m long bent to shape, 2 Nos 25x3mm M.S.F.I. clamps of suitable size & shape, rugged bolts grouted in walls/columns, nuts, washers etc. and electrical connection with and including 3 core 0.5sqmm copper conductor PVC insulated and sheathed cable of required length from ceiling rose to connector block of the luminaire, complete all as specified and directed
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 5 of MES SSR-1991 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe for watering purpose and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion. NOTE:-GI lead wire and GI pipe for encasing GI lead wire beyond 7.50m length per earthing if so required at site shall be measured and paid separately under relevant items.
SCHEDULE PART - IV (B) (EXTERNAL WATER SUPPLY)
Supply, laying, jointing & testing ductile iron pressure pipes for water supply of class K-7 with socket and spigot ends with cement mortar lining inside the pipe and zinc coated outside as per IS -8329/2000 in available lengths suitable for push on tyton joints ( rubber gasket D-jointing) laid in trenches all as specified and directed and shown on drawings of nominal dia 100mm (DN-100).
Supply, laying, jointing & testing ductile iron pressure pipes for water supply of class K-7 with socket and spigot ends with cement mortar lining inside the pipe and zinc coated outside as per IS -8329/2000 in available lengths suitable for push on tyton joints ( rubber gasket D-jointing) laid in trenches all as specified and directed and shown on drawings of nominal dia 150mm (DN-150).
Supply, laying, jointing & testing ductile iron pressure pipes for water supply of class K-9 with socket and spigot ends with cement mortar lining inside the pipe and zinc coated outside as per IS -8329/2000 in available lengths suitable for push on tyton joints ( rubber gasket D-jointing) laid in trenches all as specified and directed and shown on drawings of nominal dia 100mm (DN-100).
Note for item No 6.01 to 6.03 of BOQ:- Excavation & earth work , M & L for joints and DI specials/fittings shall be measured and paid separately
Supplying, installing, testing and commissioning of heavy duty high performance and high efficiency centrifugal self priming non-clog automatic air release type single or double stage monobloc pump set of capacity 6.9 LPS at 64 metre head having volute CI casing with bronze impeller high tensile carbon steel shaft with hardened chrome steel shaft protection sleeve gland packed stuffing box or with mechnical sealing arrangement having 80/65 mm dia suction and 50/65mm dia delivery coupled with robust design 1450 RPM, 415 volts, 3 phase TEFC AC electric induction motor of suitable HP/KW rating as per manufacturers design with tall fins for better heat dissipation and having 'B' class insulation complete alongwith PCC foundation and fixing bolts nuts etc as recommended by the manufacturers, CI foot valve of required size/ dia in suction pipe, connected with and including fully automatic oil immersed star / delta starter of suitable rating by means of suitable size of stranded copper conductor cable complete with all standard accessories and including supply of 2 years normal maintenance spares as recommended by the manufacturers, type Kirloskar monoblock KDS 1575 or equivalent of other specified makes including M&L for all joints, jointing material with suction and delivery pipes, complete all as specified and directed.
S&F ductile iron fittings (PN-1.0) as per IS -9523/2000 with inside cement morter lining and outside bitumen coating suitable for ductile iron socket and spigot pressure pipes for water upto 250 mm nominal bore suitable for push on tyton joints (rubber gasket D-jointing) fittings consisting of double socketted or double flanged of spigot and socket bends, any type and radius any angle Tees all socketted or all flanged or double socketted with a flanged branch (equal or unequal) double socket tapers flanged adoptors, mechanical joint collars caps blank flanges / plates etc, as required at site heavy duty having K-12/K-14 thickness corresponding to its DN, complete all as specified and directed. (Note :- M & L for joints and jointing material shall be measured and paid separately)
M & L for jointing D.I spigot and socket pipes with rubber tyton joints complete all as specified and directed of following sizes :-
(a) 150mm bore
(b) 100mm bore
(c) 250mm bore
Supply, fix and testing cast iron sluice valve with GM spindle both ends flanged and drilled bonnet wedge stuffing box gland thrust plate hand wheel made out of grey cast iron complete valve and its fitting suitable for hydraulic test pressure of 15Kg/Sq cm PN 1.0 ISI marked complete all as specified and directed of 80 mm bore.
Supply and fix M.S. heavy duty flanges with predrilled holes internally screwed suitable for fixing on externally screwed G.I. pipe of size 80mm, M & L complete all as specified and directed.
Material and labour for PCC solid block C5 grade masonry chamber (valve pit) built in cm 1:6 for sluice valves / stop valves etc; all as shown on drg No VEPZ/93/TD/20 including necessary excavation and earth work in any type of soil/ strata etc complete all as specified and directed of following internal dimensions :-
(a) 600 x 600 x 600 mm
(b) 900 x 900 x 900 mm
S&F Gun metal non return valve both end flanged PN 1.6 confirming to IS suitable for 50mm bore delivery pipe all as specified & directed.
--do-- all as per item No 6.16 above, but of cast iron suitable for fixing on 100mm bore pumping main, both ends flanged. (Note for item Nos 6.16 & 6.17 :- M&L for flanged joints shall be measured and paid seperately)
SCHEDULE PART - V (B) (EXTERNAL ELECTRIFICATION)
M & L for provision of pole earthing with galvanized steel earth plate electrode 600 x 600mm x 6mm thick buried vertically in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of the plate burried vertically at a depth not less than 1.5 metre below ground level connected to and including galvanized steel earth lead wire 4.0mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized steel earth lead wire encased in and including 15mm bore GI light grade protection pipe starting from top edge of earthplate and upto 2.40 metre height from G.L along the pole fixed by means of and including 25 x 3mm M S F I clamps, bolts, nuts washers etc, then, GI earth lead wire to be fixed bare along the pole and connected to O/H continuous earth wire, looped to gang operated air break switch on pole , with provision of a mixture of charcoal dust and common salt packed all around the earth plate, including necessary excavation and earthwork in any type of soil/strata, complete all as specified and directed and shown on electrical plate No 5 of SSR-91 (Part I) Note : (i) These earthings shall be provided for H.T 2 pole / 4 pole structure GOD & LT poles and shall be without provision of PCC earth pit and watering arrangement. (ii) Any length of G I. earthlead wire shall be provided as per site requirement and no extra payment shall be admissible but 15mm dia G.I light grade pipe shall be provided to an extent of 7.5 meters only per earth.
Provision of earth for H.T / L.T equipments and for H.T. 11 KV lightening arrestor set with 600 x 600 x 6mm galvanized steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 meters below normal ground level with top edge of the plate vertically at a depth, not less than 1.5 metre below ground level connected to and including G.I strip of size 32 x 6mm by means of bolts/ nuts/check nuts/ washers of galvanized steel, G.I strip encased in and including 50mm bore G.I light grade protection pipe starting from edge of the earth plate and laid in ground / floor etc, both G.I strip and pipe to be provided to the extent of 7.5 meters, G.I strip to be duly connected to the metallic bodies of H.T / L.T. equipments, with provision of mixture of charcole dust and common salt packed all around the earthplate including necessary excavation and earth work in any soil/ strata, provision of concrete earth pit using PCC 1:2:4 type B1 alongwith M.S. angle iron frame and 20mmdia G.I medium grade pipe from top edge of earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete all as shown on electrical plate No 5 of SSR Part I (1991) and testing on completion.
Supply and fix road lighting lantern (street light luminaire) suitable for and including 1x70 W HPSV lamp comprising of single piece die cast LM-6 aluminium housing in stove enamelled hammer tone grey finish from outside control gear housing (Compartment) comprising of a heavy duty copper wound ballast power factor improvement capacitor, 3 wire electronic ignitor, 3 pin skirted porcelain GES (E40) lamp holder all accessory pre-wired upto 2 way, 10 Amps GFP mains connector block inside the control gear housing, suitable for terminating 4 Sqmm incoming cable earthing terminal suitable for receiving 14SWG steel wire, lamp compartment comprising of pre-anodised high purity aluminium pot, optics porabolic reflector for excellent light control and distribution in longitudinal and transverse directions and for high photometric efficiency, brightened by electro-chemically coated ALSILICA for better uniformity and high optical performance, and elegantly shaped high transparency clear acrylic bowl cover fitted with anti moth weather proof felt gasket impregnated with insecticide to prevent ingress of insects hinged at one end clamped to the canopy by means of anti corrosive stainless steel single action spring loaded loggles complete luminarie confoirming to IS-10322 Part-5 section-I of make Phillips SRX066/70(E) , WIPRO WSS-20070, Crompton SSG-21071 H/W1 including suitable mounting/fixing arrangement with swan lock/ perabolic type to LT steel tubular poles M&L complete all as per specified and directed.
Supplying, fixing and connecting electrically post top lantern, suitable for and including 1 x 80watt HPMV lamp, integral type decorative diamond shaped consisting of integral self contained control gear capsule die-cast LM-6 aluminium alloy spigot MBV treated housing and pressure ring, heavy duty copper wound ballast PF capacitor lamp holder 3 pin BC/ES-27 poreclain 2 way 10 Amp GFP mains connector for 4 Sqmm incoming cable earthing terminal to receive earthwire all accessories pre-wired upto connector block high density vendal proof rota moulded polyethylene HDPE diffuser, UV stabilized double conical shaped fitted with spigot by means of double spring loaded bezel ring and weather proof gasket confirming to IP-43 protection and IS-10322 Part-5/Sec-1 of 1987 make Philips HPC-104/80 (I) HPF or equivalent of Crompton MPT 11121L/BM/BC for (80W HPMV)/WIPRO WPM 27080 makes Note : GI pipe posts of required length and dia for mounting the lantern shall be measured and paid for seperately under relevent item of this schedule.
S & F terminal boxes of size 200 x 150 x 150mm made out of 16 guage M.S. sheet, comprising of one No insulated copper bus bar neutral link and two Nos bakelite fuse carriers (Kit-Kats) of 5Amp capacity with fuses, duly painted and to be fixed on G.I pipe post or on LT poles by means and including M.S.F.I. clamps of suitable size bolts, nuts and washers etc and connecting electrically with the luminaries connector block with and including 0.5 Sqmm 2 Core copper conductor PVC insulated sheathed cable complete all as specified and directed.
Supplying , installing, testing and commissioning pedastal type LT panel board indoor type fabricated out of 2.0mm thick CRCA sheet of suitable diamensions so as to have adequate space for mounting all items given below plus two nos motor starters, frame and pedastals made out of 50 x 50 x 6mm size angleiron, LT panel suitable for operation at 3 phase 4 wire 440volts 50Hz system complete with necessary inter connection wiring with multistandard copper conductor PVC insulated cables of suitable size, duly spray painted with one coat of red oxide primer and two coats of synthetic enamel grey hammertone or blue or any other approved colour, M & L complete all as specified and directed and consisting of following :-
(a) MCCB TP&N 415V 63A 50 Hz 25 KA-01 No (Incoming)
(b) MCB TP&N 30/32A 415 V-02 Nos (Outgoing) for pumps.
(c) MCB SP 16 Amp 240 Volts-01 No (Outgoing) for lighting DB of pump house bldg.
(d) Bus bar chamber with set of 4 Nos copper bus bar of 200 Amp capacity 300mm long mounted on FRP moulded reel type porcelain insulators.
(g) Pilot / indicator lamps LED type on each phase (R-Y-B)-01 SET.
Provision of earthing of LT panel for pumps with 600 x 600 x 6mm galvanized steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metres below normal ground level with top edge of the plate vertically at a depth not less than 1.5 metre below ground level connected to and including GI strip of size 32 x 6mm by means of bolts/nuts/check nuts/washers of galvanized steel, GI strip encased in and including 50mm bore GI light grade protection pipe starting from top edge of the earthplate and laid in ground/ floor etc. both G.I strip and pipe to be provided to the extent of 7.5 m each per earth, GI strip to be duly connected to the metallic bodies L.T. equipments with provision of mixture of charcoal dust and common salt packed all around the earthplate including necessary excavation and earth work in any soil/strata, provision of concrete earth pit using PCC 1:2:4 type B-1 alongwith MS angle iron frame C.I cover with locking arrangement and 20mm dia G.I. light grade pipe from top of earth plate upto M.S. funnel with wire mesh provided inside concrete earth pit for watering arrangement, complete all as shown on electrical plate No 5 SSR Part-I (1991) and testing on complete. Note : G.I strip and protection pipe beyond first 7.5 metres shall be measured and paid separately under appropriate item) conductor cable complete with all standard accessories and including supply of 2 years normal maintanance spares as recommended by the manufactures, type Kirloskar monoblock KDS 1775 or equivalent of ther specified makes including M & L for all joints. Jointing material with suction and delivery pipes, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0mm thick, vertically in ground (Earth pit not less than2.25 meters deep below normal ground level), connected to galvanised steel earthing lead wire 4mm dia, by means of bolts, nuts, and checknuts and washers etc. GI pipe 15mm dia light grade pipe for protection of GI earth lead wire, both to be provided to the extent of 7.5 meters, all as shown on electrical plate No 5 of MES SSR-1991 Part-I and connected to MCB DB GI protection pipe buried in ground, laid under floors/ plinth or fixed on RCC column with provision of mixture of charcoal dust and common salt packed upto minimum 150mm all around the earth plate including PCC 1:2:4 type B-1 earth pit with MS angle iron frame cast iron cover with locking arrangement with GI 20mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil/strata and testing on completion, M&L complete all as specified, directed and shown on drg.
S & F cable jointing kit for 11KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material accessories aluminium conductor cable for size 95Sqmm 3 core, all as specified and directed.
(RECTIFICATION OF DEFECTS)
Taking down carefully existing bitumenous membrane/tarfelt treatment any description and cleaning and making good damaged surface in 10mm thick cement mortar 1:3, where ever required to make surface ready to receive fresh water proofing treatment on roof and flashing and junctions of parapet, kerb, wall etc. and removing rubbish out of defence land.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for.
M & L for plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) in steps, parapets and copings, kneelers, bases for water tanks, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork.
M & L for Waterproofing treatment to roof including flashing and junctions of parapet, kerb, wall etc. as under:- (a) Applying bituminous primer on cleaned and dried surface @ 0.20 Kg/Sqm. (b) Laying on primed surface by thermo fusion (torch application) 3mm thick APP based polymeric water proofing membrane weighing not less than 3.50kg/sqm and reinforced with polyester non woven fabric (not less than 160 gms/sqm). (d) Painting the exposed APP membrane surface with bituminous aluminium paint @ 0.15 Kg/Sqm.
S & F Vitreous China water closet squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding fixed in repairs.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises .
M&L for glazed ceramic coloured tiles size 350x250x7mm thick in vertical surface, set and jointed in neat cement slurry & pointed with coloured cement to match, laid over and including rendering 10mm thick in Cement Mortar 1:4 as in backing coat on fair surfaces of brick wall.
M & L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. laid over and including 15mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L for repair of hair line crack developed in wall and ceilling surface by racking the cracks and filling the crack by grouting the chemical paintex-4 and applying two coats of distemper over a coat of primer.
M& L for two coats of cement based paint on walls including preperation of old treated plastered or unplastered surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots; removing nails, making good holes, cracks etc. by filling with putty.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. all as specified.
M & L for rendering 15mm thick in cement mortar 1:4, mixed with water proofing compound on faces of brick work or concrete surfaces including smooth finish without using extra cement. Note: Water proofing compound will be measured and paid for separately.
Supply only liquid water proofing compound ISI marked.
M&L for special treatment to sunken portion with 10mm thick plaster in Cement Mortar 1:4 by using Ditachment DM 1% by weight of cement and surface made smooth after curing period, two coats of Ditachment DS shall be applied @2.50 Kg/Sqm. The paste like consistancy is made by using 2.5 Kg of Ditachment DS powder in one litre of admixture (The admixture is made by dissolving 1 part by volume of Nafufill SBR & 4 part by volume of water). After 7 days curing, testing shall be done to flooring for 72 hours. Finally protective plaster coat of 10mm thick in Cement Mortar 1:4 shall done by using Putz Ditachment 1% by weight of cement over layer of Detachment DS. All joints of CI Pipe, Nahani trap, WC connection etc. shall be filled by mixture of cement, fine sand and 10% Nafufill SBR by weight of cement 32mm dia 450mm long GI Spout light grade shall be provided in all sunken slabs to drain off water
DARSHAN CONSTRUCTION Co.
MUDRIK ENTERPRISES
SHELDON CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .