| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC L1 Bid | |
| 2 | L2₹42.0 L+₹5.8 L (16.2%)Rejected-AOC ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | L2 | Rejected-AOC L2 bid | |
| 3 | L3₹43.3 L+₹7.1 L (19.7%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC L3 Bid | |
| 4 | L4₹46.5 L+₹10.4 L (28.7%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L4 | Rejected-AOC L4 Bid | |
| 5 | L5₹46.6 L+₹10.4 L (28.8%)Rejected-AOC | L5 | Rejected-AOC L5 Bid |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
30 Dec 2019, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
REPAIR/REPLACEMENT AND MAINTENANCE OF CENTRAL AC PLANT COMPRESSOR, COOLING TOWER AND CONNECTED MISCELLANEOUS E/M WORKS AT CGDA UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2019_MES_272344_4
GE/BH-26/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
9 documents required · 9 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹99,800
Yes
21 Jan 2020
3 Dec 2019
1 Jan 2020
4 Dec 2019
30 Dec 2019
16 Dec 2019
Amount
M & L for Dismantling of compressor of central AC plant (180 TR) for overhauling complete with connected copper pipe line and loading unloading mechanism & pump down the existing refrigerant in separate cylinder,disconnecting of electric motor of compressor ,refrigerant line , gauges pipe , & connecting accessories and carry out the over hauling of compressor for both A & B circuit, compressor model:- 30HXC190A Make:- CARRIER including S & F in replacement of following parts:- a) springs b) aluminium washer packing c) main compressor screws of all types d) lath work e) cleaning chemical work f) oil supply solenoid valve g) changing of compressor oil h) oil pump sensor i) changing the suction filter j) oil filter k) suction & economizer screens l) oil separater m) oil pumps n) motor cooling valves o) motor temp sensors ( termisters 02 types) p) HP sensor with Probe q) LP sensor with Probe r) loading and unloading mechanism s) oil recovery system t) Replacing the defective parts compete system for safe guard the gas with self pumping down system or with total recovery unit system.
The job include the following work:- (i) Labour charge for removing the defective compressor from system. (ii) Loading and unloading, to & fro transfortation of compressor from site to work shop & back to site. (iii) Dismantling of defective screw compressor at workshop including removing the termination lead connections, taking out of all parts,replacements of defectiveparts & assembling & testing the same. (iv) pisitioning the duly repaired compressor on the base of chiller. (v) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (vi) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (vii) Charging of complete system with R - 134A gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.... (viii) Measure the inlet and outdoor temperature of Chiller unit for performance checking and maintaining temp. as per require site. (ix) Testing & commissioning of compressor after completion.
Note 01: Contractor should arrange necessary T & P and manpower to take out unserviceable part of plant and transporting the same to worshop for overhauling and re fixing the same at existing position after overhauling all as specified and directed by engineer in charge. The Quoted rates inclusive all and no extra co host admissible in this regard Note 02 : contractor should arrange necessary vehicle from factory inspection by AGE E/M and JE E/M for this dismentalized AC parts and after completing of overhauling. So for two times during for overhauling of complete engine in workshop vehicle will arrange and rate of that inclusive in quoted rate. Note 03: Contractor should make necessary arrangement of testing of the complete set 100% load condition and testing can be carried out 06 hours period.Gas , Compressor oil and other required if any for making it RUN will be responsibility of contractor and rate quoted by contract contractor will be inclusive of all. 04:- Job card will be maintained after repaired by OEM and will be produced for tech check while making payment to contractor.
Attending of complaint/ any breakdown in AC plant and connected assessories in 2-4 hours of intimation by JE/ AGE E/M in CGDA complex for carrier AC plant 3X 180 TR Motol : 30HXC190A and make them functional, if any item required the same shall be measured from particular item from schedule for complete contract. Note 01:- If complaint intimation is done after 1600 hrs then complaint to be attented by contractor at 800 hrs next day. Note 02 : If contractor failer to attend complaint with in time frame, the recovery of Rs2000/ Hrs will be implemented . 03-: Job card will be maintained after repaired by OEM and will be produced for tech check while making payment to contractor. 04:- Job card will be maintained after repaired by OEM and will be produced for tech check while making payment to contractor.
Attending of complaint/ any breakdown in hot water Generator and connected assessories in 2-4 hours of intimation by JE/ AGE E/M in CGDA complex Ac plant Make ACCEL 3X 15 TR Model SMC 4/ 65 and make them functional, if any item required the same shall be measured from particular item from schedule for complete contract period. Note 01: - If complaint intimation is done after 1600 hrs then complaint to be attented by contractor at 800 hrs next day. Note 02 : If contractor failer to attend complaint with in time frame, the recovery of Rs2000/ Hrs will be implemented 03:- Job card will be maintained after repaired by OEM and will be produced for tech check while making payment to contractor.
Attending of complaint/ any breakdown in 3X 15 TR AC plant and connected assessories in 2-4 hours of intimation by JE/AGE E/M in CGDA complex for HOT Water Generator and make them functional, if any item required the same shall be measured from particular item from schedule for complete contract period.Make Accel Note 01: - If complaint intimation is done after 1600 hrs then complaint to be attented by contractor at 800 hrs next day. Note 02 : If contractor failer to attend complaint with in time frame, the recovery of Rs2000/ Hrs will be implemented. 03:- Job card will be maintained after repaired by OEM and will be produced for tech check while making payment to contractor.
Supply and fixing in repair EXV card with control panel and other accessories suitable for the model no. 30HXC190A Make:- CARRIER as directed by Engineer in charge.
Supply and fixing in repair SCPM card for the model no. 30HXC190A Make:- CARRIERas directed by Engineer in charge.
Supply and Replacement/topping up synthetic oil ( 01 pail = 18. Ltrs.) in screw compressor suitable for carrier 30HXC190A 3X 180TR as directed and specified by engineer in charge.
Supply and fixing in repair internal oil filter for suitable the model no. 30HXC190A Make:- CARRIER as directed by Engineer in charge.
Supply and fixing in repair drier core suitable for the model no. 30HXC190A Make:- CARRIERas directed by Engineer in charge.
Supply and Filling of refrigerent R- 134A as directed and specified by engineer in charge.
Supply and fixing in repair external oil filter suitable for the model no. 30HXC190A Make:- CARRIERas directed by Engineer in charge.
Supply and fixing in repair Expansion Valve for chiller unit of central AC plant of Cap 180 TR for the model no. 30HXC190A Make:- CARRIER as directed abd specified by engineer in charge.
Supply and fixing in repair Economizer pressure sensors suitable for the model no. 30HXC190A Make:- CARRIERas directed by Engineer in charge.
Supply and fixing in replacement HRC fuse of cap 160 amp 230 volt Model HN Size 00 as directed by Engineer in charge.Make L & T Cat No. SF94939
Supply and fixing in replacement fuse of cap 32 amp 230 volt bottled type HF complete as directed by Engineer in charge.Make L & T Cat No. SF90142.
M & L for Pump down of refrigerant into empty cylinder with recovery unit from complete refrigerent cycle of central AC plant (Circuit A and B )Model 30HXC190A Make Carrier fot finding out leakage from the systemasdirected & specifed by Engineer in charge. a) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. b) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. c) Charging of complete system with R - 134A gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi as specified and directed by engineer in charge. d) Testing & commissioning of compressor after completion.
Supply & fixing in replacement MCCB 415 Volts 50 Hz, Three Pole, 630 Amps capacity 50 KA, with thermal release . Make L&T Model DH 630 or eqivalent in Legrand / Schnider all as specified & directed by Engineer in charge.
Supply & fixing in replacement MCCB 415 Volts 50 Hz, Three Pole, 100 Amps capacity 16 kA, with thermal release range upto 63 Amps. Make L&T Model DH 100 or eqivalent in Legrand / Schnider all as specified & directed by Engineer in charge.
Supply & fixing in replacement MCCB 415 Volts 50 Hz, Three Pole, 160 Amps capacity 25 KA, with thermal release range upto 63 Amps. Make L&T Model DH 100 or eqivalent in Legrand/ Schnider all as specified & directed by Engineer in charge.
Supply & fixing in replacement LED based Indicator Lamp (R,Y,B led type) as required at site. Make : L&T/seimens/ ABB all as specified & directed by Engineer in charge.
Supply & fixing in replacement Start/ stop Button for Starter Pannels as required at site. Make : L&T or equivalent all as specified & directed by Engineer in charge.
Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 9-15A. Model MN2. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 14-23A. Model MN2. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 20-33A. Model MN2. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 12. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 25. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 32. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 18. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 22. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply only Power Contactor type MO of size Fr0, suitable for existing starter pannel. Model MO 12. Make : L&T or equivalent in Legrand / Schnider / Seimens all as specified & directed by Engineer in charge.
Supply and fixing in replacement of fan belt of size B 138 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply and fixing in replacement of fan belt of size B 124 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply and fixing in replacement of fan belt of size B 116 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply and fixing in replacement of fan belt of size B 140 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply and fixing in replacement of fan belt of size B 101 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply and fixing in replacement of fan belt of size B 82 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply and fixing in replacement of fan belt of size B 145 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply and fixing in replacement of fan belt of size B 136 as per requirement. Make Fenner in any reputed make as dircted by engineer in charge.
Supply, Laying, jointing and testing of under electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge for the following (Make:- Havells/Polycab/KEI):-
4 core 10 Sqmm
4 core 16 Sqmm
4 core 25 Sqmm
3.5 core 70 Sqmm
3.5 core 95 Sqmm
SUPPLY AND FIXING in repair butterfly valve with CI body, stainless steel disc, nitrile rubber seal & O ring suitable pressure rating also complete all as specified & directed by Eng- in-Charge. Sizes are following:-Make Kartar / Kisloster
80 mm dia
100 mm dia
200 mm dia
S&F in repair POT Strainer of ductile Iron body flanged ends with stainless steel strainer,existing rustling pipe cutting with nut bolt etc complete all as specified & directed by Eng- in-Charge. Sizes are following:-Make-Kartar/ kirloskar/ L & T
80 mm dia
100 mm dia
250 mm dia
S&F in repair with anchor fastener angle iron , MS flat to support duct with angle iron, flats, nut bolt washers etc. Necessary welding work involved is also deemed to be included in quoted rate include cutting fabrication welding of angle iron / MS Flat, repair to RCC wall, cost of anchor fastener etc
S&F in repair single phase preventor Minilec VSP-2 suitable for 3 phase supply 415 volt. Make:- SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S /Minilec
M&L for taking out Cooling Tower Motor, 10 hp capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including, bearing insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge Note : The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa
S&F in Repair/ replacement installation and testing and commissioning of cooling tower pump 10 HP, 720 rpm 3 phase 415 volt incl. fixing the the complete with all accessories and connection with existing pipes etc complete all directed and specified by engineer in charge. Make-Kisloskar/ CG/ ABB. Note : The existing Motor to deposited to MES Store Yard.
M&L dismantalling AHU induction motor from AHU base plate inside and arranging the necessory adjusting from fan belt , and then repairing /servicing AHU Fan Motor, following below capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed Note : The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa
15 HP AHU fan motor, 1450 RPM, HX+160MLE4 Make-ABB
12.5 HP AHU fan motor,1455 RPM , HX+160MLB4 Make-ABB,
20 HP AHU fan motor,1450 RPM, HX+160MLE4 Make-ABB,
10 HP AHU fan motor, 1440 RPM AM132MZ4 Make-ABB,
7.5 HP AHU fan motor, 1454 RPM MZBA132S-4 Make-ABB,
M&L for repairing /servicing the centrifugal pump of following capacities by disconnecting the pump from motor, opening for inspection, replacing the worn out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing complete all as specified and directed by Engr-in-charge.
Condenser Pump of Head 25.4 Mtr, Discharge -190.3 M3/hrs or 53 LPS of any HP
Chillar Pump of Head-14.6 Mtr, discharge -107.4 m3/hrs or 30 LPS of any HP
HOT Water Generator Pump of Head 23.7 Mtrs, Discharge 80.2 m3/hrs or 22.5 LPS of any HP
M&L for taking out electric motor from the centrifugal pump set, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing and drying, reassembling, refixing in same position & connecting complete including testing and commissioning complete all as specified & directed by engineer in charge
Chiller motor of capacity 5.5 HP
Hot Water GeneratorPumps of capacity 7.5 HP
condensor motor 18.5 KW/25 HP
Material & Labour for rewinding of electric motor 1.5 /2 HP, 415 volts, single/three phase, using Super enameled copper winding wire of gauges equal to or more than existing including replacement of sheet ‘E’ class insulation and sleeve Including the following jobs: (a) Reassembling the motor & refixing (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and Directed by Engineer-in -charge.
Material & Labour for rewinding of electric motor 1.5 HP, 415 volts, single phase, using Super enameled copper winding wire of gauges equal to or more than existing. Including Replacement of sheet ‘E’ class insulation and sleeve Including the following jobs: (a) Reassembling the motor & refixing (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and Directed by Engineer-in -charge.
Dismantling of compressor of central AC plant for overhauling complete with connected copper pipe line and loading unloading mechanism & pump down the existing refrigerant in separate cylinder,disconnecting of electric motor of compressor ,refrigerant line , gauges pipe and carry out the general over hauling of compressor, compressor model:- SMC/4/65, Make:- Accle(R-22) including replacement of springs,aluminium washer packing, screw, lath work, cleaning detergent, cotton waste, changing of compressor oil etc and cleaning the suction filter , oil filter, replacing the defective parts compete system for safe guard the gas with self pumping down system or with total recovery unit system and (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any.(iii) Charging of complete system with R - 22 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.... (iv) Measure the inlet and outdoor temperature of Chiller unit for performance checking and maintaining temp. as per require site. (v) Testing & commissioning of compressor after completion. Note :-(a) Spares of compressor shall be measured and paid separetely under respective item of this schedule (Sr. No 52 to 73). (b) Any other items required for overhauling except described here -in - after shall be supplied by the contractor with out any extra cost to the deptt and the rates for the same shall deemed to be included in the quoted rates.
Supply only PISTON with PIN &Rings (ACCEL Part No. ASL6018R)
Supply only CYLLINDER with suction valve (R-22)(ACCEL Part No. ASL6019A)
Supply only OIL pump(ACCEL Part No. ASL6011A)
Supply only Discharge valve assembly(R-22)(ACCEL Part No. ASL6020 A)
Supply only Oil pressure regulation valve(ACCEL Part No. ASL6022 R)
Supply only Set of gasket(ACCEL Part No. ASL6453)
Supply in replacement of only Set of neoprene ' O' RINGS(ACCEL Part No. ASL6454)
Supply in replacement ofDowty ring(ACCEL Part No. ASL6455)
Supply in replacement of Set of SEALING RING(ACCEL Part No. ASL6456)
Supply in replacement of SPRING FOR SAFETY HEAD(ACCEL Part No. B-12)
Supply in replacement of HALF SECTION OF BRG. STD.(ACCEL Part No. E-02)
Supply in replacement of BEARING WITH BUSHING STD(ACCEL Part No. C-03)
Supply in replacement of DOWEL FOR BUSHING COLLAR(ACCEL Part No. C-17)
Supply in replacement of CONNECTING ROD ASSEMBLY (ACCEL Part No. ASL6017 A)
Supply in replacement of OIL STRAINER(ACCEL Part No. ASL6033 A)
Supply in replacement of CRANKSHAFT - FOR SMC/4/65(ACCEL Part No. ASL6416 A)
Supply in replacement of SINGLE FRAME ASSEMBLY(ACCEL Part No. UN-FRM-65)
Supply in replacement of UNLOADING CYLINDER ASSEMBLY(ACCEL Part No. ASL6012A-1)
Supply in replacement of UNLOADING CYLINDER ASSEMBLY(ACCEL Part No. ASL6012A-2)
Supply in replacement of SHAFT SEAL ASSEMBLY(ACCEL Part No. ASL6010 R)
Supply in replacement of SUCTION STOP VALVE ASSEMBLY(ACCEL Part No. ASL6025 A)
Supply in replacement of DISCHARGE STOP VALVE ASSEMBLY(ACCEL Part No. ASL6026 A)
M & L for dismantling the cooling tower and its connected accessories of 30 TR from roof at 5-6 m height above the ground as directed by engineer in charge. Note:- Rates must incld unloading the tower from height using necessory tools, transportation, Loading and unloading in & from Lorry as directed.
S&F Testing, Commissioning of cooling Tower with all accessories corroision proof PVC Filling, inlet louvers, drift, PVC eliminators,PVC water distribution chamber and nozzeles( self rotating sprinklers) GI nut bolt (included float valve)and all fitting as per specified & directed by Eng-in- Charge.Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b)The induced draught cooling tower should be operate according to the counter flow principle. (c) cooling tower specification for pvc filling .Make : Delta/ Mihir/Pharpur/Polo/EPP Composites Pvt Ltd/Advance. (i) Capacity - 30 TR (ii) model - 5031 (iii) water Flow - 120 LPM (iv) Water in - 36.4° C (v) Water out - 32.2° C (vi) Design wet bulb temp - 28.3° C (vii) Shape of Cooling Tower- Round /Square (viii) Type of Cooling Tower - Induced draft counter Flow, (ix) Height- 3000mm, (x) Daimeter-1850, Fan Details (i) Nos of Fan - 01 Nos, (ii) Fan Blades-04 Nos, (iii) Fan Daimeter -900mm (iv) Fan Material- Aluminium, (v) Fan Speed - 960 RPM , (vi) Air Quality - 7560 CFM, Fan Type- Axial Flow, Motor Detail - Nos of Motors -01 Nos, (ii) Motor Power - 2 HP, Motor Speed- 960 RPM, (iii) Enclousure - TE WP with IP-55 Protection , 415V/3 Ph/50 Hz, (iv) Type of Motor- Extended Shaft, Squirrel cage Induction Motor. Material of Construction- (i) Basin- FRP (ii) Casing- FRP, (iii) Drift Eliminator- PVC (iv) Water Distrubution pip- PVC, (v) Fills- PVC, (vi) Hardware - GI, (vii) Ladder -GI, (viii) Sprinkler - Aluminium (ix) Splash Cap -01, (x) Mechanical Eqpt Support- Hot Dip Galvanised Mild Steel. Note :- Quoted rates are to be incld the PCC foundation as recommended by OEM and test report of cooling tower producce by contractor as per OEM.
S&F in repair condenser water or cooling tower piping of MS 'C' class confirming to IS-1239 and IS- 3589 both revised till date as required and as specified and complete with bends , reducers tees, supports vibration pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and complete all as per specified & directed by Eng-in-charge. Sizes are following:-80mm
Supply and laying M.S tubing Heavy grade including M.S fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench complete all as specified and as directed of size:-100mm
S&F in repairs MU/MB DOL Staters of capacity 7.5HP, 3 phase motor 415V, 50 Hz with relay range 9-15 A having MN relay function. Model MB1 DOL Make : L&T/ Havells
S&F Electronic timer for star delta motor stater model 0538A or 0638A, 20 SDTO. Make : L&T/ Havells/EE
M&L for descaling of condensser tube of central AC plant of cap 180TR by disconecting the condensser from the system , cleaning by descaling pump of suitable capacity of 110 ' feet head using descaling solution of make Hibird cleaning condenssor tube by nylon bursh & MS rod of suitable size , replacement of rubber joints and unserviceable nut bolts ( Note :- Arrangment of T&P such as pump, tube , descaling solution shall be carried out by contractor.Make Carrier (solution)
M&L for descaling of condensser tube of central AC plant of cap 15TR by disconecting the condensser from the system , cleaning by descaling pump of suitable capacity of 110 ' feet head using descaling solution of make Hibird cleaning condenssor tube by nylon bursh & MS rod of suitable size , replacement of rubber joints and unserviceable nut bolts ( Note :- Arrangment of T&P such as pump, tube , descaling solution shall be carried out by contractor.Make Carrier (solution)
S&F in repair pre filter having HDPE media with Aluminium GI Frame & Filter as per the existing size of (610x610x50)mm As per sample Make Zeco/Arthalete as directed and specified by engineer in charge
S&F in repair pre filter having HDPE media with Aluminium GI Frame & Filter as per the existing size of (610x305x50)mm As per sample Make Zeco/Arthalete as directed and specified by engineer in charge
S&F in repair pre filter having HDPE media with Aluminium GI Frame & Filter as per the existing size of (305x610x50)mm As per sample Make Zeco/ Arthlete as directed and specified by engineer in charge
S&F in repair pre filter having HDPE media with Aluminium GI Frame & Filter as per the existing size of (305x350x50)mm As per sample Make Zeco/Arthalete as directed and specified by engineer in charge
Dismanting of sides from base sides prefabricated PUF panel corners of AHU inside existing AHU room with required T & P and manpower. dimantaling of all chiller water pipe items (inlet & outlet ) with connected nut & bolts and gaskets and put in safe custody for Reuse. Dismantling of existing corrorded & rusted cooling coil of AHU from inside of AHU including connected items and then S&F in repair cooling coil 1/2" GI coil casing copper tubing 1/2" outer dai, thickness of tube 0.41 mm,MS Header, 0.15mm and Aluminium Fins, space of fins per inch (FPI) 11-12, CWC Coil, CFM -26000, Fins height-925.5mm, Fins Length -2537mm, Make Zeco / Athalete along with connected fixing brackets etc with complete as per specified& directed by Eng-in-Charge with refixing the above said dismantled parts and perform testing & commissioning the working as directed.
Dismanting of sides from base sides prefabricated PUF panel corners of AHU inside existing AHU room with required T & P and manpower. dimantaling of all chiller water pipe items (inlet & outlet ) with connected nut & bolts and gaskets and put in safe custody for Reuse. Dismantling of existing corrorded & rusted cooling coil of AHU from inside of AHU including connected items and thenS&F in repair cooling coil 1/2" GI coil casing copper tubing 1/2" outer dai, thickness of tube 0.41 mm,MS Header, 0.15mm and Aluminium Fins, space of fins per inch (FPI) 11-12, CWC Coil, CFM -11000, Fins height-1206.5mm, Fins Length -1695mm, Make Zeco/ Athlete along with connected fixing brackets etc with complete as per specified& directed by Eng-in-Charge with refixing the above said dismantled parts and perform testing & commissioning the working as directed.
Dismanting of sides from base sides prefabricated PUF panel corners of AHU inside existing AHU room with required T & P and manpower. dimantaling of all chiller water pipe items (inlet & outlet ) with connected nut & bolts and gaskets and put in safe custody for Reuse. Dismantling of existing corrorded & rusted cooling coil of AHU from inside of AHU including connected items and thenS&F in repair cooling coil 1/2" GI coil casing copper tubing 1/2" outer dai, thickness of tube 0.41 mm,MS Header, 0.15mm and Aluminium Fins, space of fins per inch (FPI) 11-12, CWC Coil, CFM -16500, Fins height-889mm, Fins Length -1725mm, Make Zeco / Athlete along with connected fixing brackets etc with complete as per specified& directed by Eng-in-Charge with refixing the above said dismantled parts and perform testing & commissioning the working as directed.
S&F in repair treminal connector close type 30 amp 12 way of bakelite as directed and specified by engineer in charge Make : L & T / Schnider / ABB
S&F in repair power block 3 ph connectors DMC with transparnt patti 100 amp 4 way directed and specified by engineer in charge Make : L & T / Schnider / ABB
Supply and charging/ topping up R-22 as directed and specified by enginner in charge.
CHOUDHARY ELECTRICAL
RUCHIKA ENGG.WORKS
Saini Enterprises
M/s Birja Nand
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .