Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.1 LAccepted-AOC 67 RAMPURA GANDHI NAGAR JAMMU 180 004 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹1.1 Cr+₹10.3 L (10.5%)Rejected-Finance PO PS JANG DISTRICT TAWANG ARUNACHAL PRADESH 790104 | JANG | TAWANG | ARUNACHAL PRADESH | 790104 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹1.2 Cr+₹19.5 L (19.9%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹1.2 Cr+₹24.6 L (25.1%)Rejected-Finance 45 ADARSH COLONY UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹1.2 Cr+₹25.2 L (25.7%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹99 L
EMD Value
₹1.7 L
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE (AF) Jammu
Headquarters, CWE (AF) Jammu, Near Gurdwara Sahib and Mandir, Airforce Station Satwari, Jammu. Pin - 180 003
PROVN OF ELECTRICAL INFRASTRUCTURE AND ASSOCIATED WORKS SERVICES FOR OPERATIONALISATION OF IPSS AT AF STN UDHAMPUR
2023_MES_602955_1
CWEAFJ-09/2023-24
Open Tender
Civil Works
Lump-sum
270 days
GE (AF) Udhampur
All As Per Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (AF) Udhampur
₹1.7 L
Yes
2 Sept 2023
13 Jun 2023
26 Jul 2023
13 Jun 2023
24 Jul 2023
6 Jul 2023
Amount
Schedule 'A' Part-I (Building Work) Note : This schedule for Schedule 'A' PART-I is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only.
Construction of Building for Operationalisation of IPSS, RCC framed structure with RCC roof in M-25 Design mix including ATT & WPT complete, all as shown on drawings and as specified.
Schedule 'A' Part-II (Internal Electrification) carried forward from pre-priced Schedule.
Schedule 'A' Part-III (Internal Water Supply) carried forward from pre-priced Schedule.
Schedule 'A' Part-IV (Plumbing Work) carried forward from pre-priced Schedule.
Schedule 'A' Part-V (Site Clearance) carried forward from pre-priced Schedule.
Schedule 'A' Part-VI (Sewage Disposal) carried forward from pre-priced Schedule.
Schedule 'A' Part-VII (Path) carried forward from pre-priced Schedule.
Schedule 'A' Part-VIII (External Electrification) carried forward from pre-priced Schedule.
Schedule 'A' Part-IX (Air Conditioning) carried forward from pre-priced Schedule.
Schedule 'A' Part-X (Fencing) carried forward from pre-priced Schedule.
Schedule 'A' Part-XI (Miscellaneous Items for B/R & E/M Rate Schedule) This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only.
Mild steel powder coated black sheets of size 30 cm width as cable duct trays and similar work cut to size, holes punched including round headed screws clout nails or revets and fixed to wood or steel framing with 40 mm lap joints with revetted seams including bending or turning up mitered angles etc as required made out of 3.15 mm thick sheet complete as specified and directed.
RCC Septic Tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users complete all as specified and shown on drg No CWE(AF) J /TD-14 /23 Sheet No. 1/3 to 3/3 dated 20 Mar 2023.
Soakage Wells , excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats effiective depth of size 3.00 M dia x 6.00 M complete all as specified and as per drg No. CE/AF/STD-15/2000 SHEET 1/2 TO 2/2.
Transformer Platform of size 3.0x3.0x1m high from GL including excavation and earth work in trenches in any type of soil, PCC 1:5:10 type E2 for foundation, brick work in CM 1:6, PCC 1:2:4 type B-1 as in coping, plaster of 10mm thick in CM 1:6 on brick surface , complete with 75mm thick PCC 1:4:8 type D-2 as in sub base of floor with topping of PCC 1:2:4 type B-1, 100mm thick in floor and finished even and fair (without using extra cement) including returning, filling in and removal of surplus spoil to a distance n.exc 50m including chain link fencing 1.8 m height made out of 4mm dia GI wire 150 x 100 mm mesh with mild steel angle iron 50 x 50 x 6mm as in fencing post and embedded in PCC 1:2:4 type B-1, 30 x 23 x 30cm block at 1.5 mtr interval each side as approved with 1 No steel gate (3.5 m clear) span as shown in TD Drg No. 1129 of Chief Engineer Udhampur Zone (Army) with locking arrangement made out of 15mm dia mild steel rod 50x50x6mm angle iron frame and painting the steel surface with 2 coats of aluminium paint over a coat of red oxide primer and 3 coats of white washing on cement work including ISMB 100mm channel 02 Nos for fixing transformer, complete all as specified, shown on drawings and as directed.
Supply, Installation, testing and commissioning of 11 KV, Outdoor unit fabricated out of 14 SWG CRCA Sheet. The panel contains the Equipments & Components complete with Aluminium Bus bar interconnections, designation labels, caution notices, EB sealing and pad locking facilities wherever required. Platform for LBS panel plinth of size 2.0x2.0x0.60 mtr high from GL including excavation and earth work in trenches in any type of soil, PCC 1:5:10 type E2 for foundation, brick work in CM 1:6, PCC 1:2:4 as in copping, plaster of 10 mm thick in CM 1:6 on brick surface/complete with 75 mm thick PCC 1:2:4 type B1 and necessary space is provided for entry of HT cables from bottom through detachable gland plates. The panel is finished with powder coated paint confirming to shade 631 of IS:5. Panel consisting of on Load Break Switch with fuse trip mechanism, 3 phase, 11 KV, 630A 1 No, HRC fuses with tripping striker pin, 11 KV suitable for not less than 630 Amps - 03 Nos, Copper Bus bar, suitable rating, 3 P, Air insulated with colour coded RYB Heat shrinkable sleeves, Earth bus, 25x3 mm copper bus bar, busbar supports : Resin cast switch including enclouser complete all as specified and directed by Engineer-in -Charge.
LT panel outdoor type bus bar chamber, made out of 3.15mm thick MS sheet comprising 04 Nos aluminium strips each of 300 Amps, 60cm long duly insulated mounted on insulators incl MCCB 200 Amp, 25 KA, 4 pole, 415 volts 50 Hz -01 No (one incoming) and 03 Nos MCCB 100 Amps, 16 KA, Four Pole 415 volts, 50 Hz (for outgoing) complete with 04 Nos mounting legs made out of 50mm x 50mm x 5mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate) and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed.
M&L for repairing of damaged water pipe line, JFC / OFC cable and HT, LT cable during laying of new cabe & erecting of pole etc, the rectification job shall be to the entire satisfaction of the Engr-in-Charge.
Supply and fixing of Plug socket board with metal socket and plug DP 20 Amps (1 Phase, 1 Neutral and Earth) complete all as specified and directed.
Supply and fix AC Voltage Stabilizer wall mounting with low and high voltage cut off, thermal overload protection, intelligent time delay system capacity 15 Amp, voltage working range 130 - 280 Vac, time delay 3 minute +/- 20 Sec ITDS of capacity 4 KVA, 230 volts, 50 Hz complete all as specified and directed.
Supply, installation, testing and commissioning of step down, transformer 11KV/433 Volts 3 Phase 50 HZ 25 KVA out door type , with off load tap changing arrangement on HT side to vary secondary voltage up to + 5% to - 5 % in steps of 2.5 % including suitable cable entry boxes both on HT to receive upto 120 sqmm 3 core XLPE cable and on low voltage side to accomodate XLPE cable of size upto 120 Sqmm 3.5 core complete in all respect with standard accessories and fitment confirming to IS-1180 Part -I of 2014 amended upto date .Primary side delta(HT) and secondary side star with neutral (LT) i.e Vector diagram Dyn-11 .The sailent feature of transformer shall be as follows :-
(a) Transformer shall be oil immersed, ON AN cooled, double coppper wound, core type with radiater cooled tank complete with first fill of transformer oil as per IS 335 amended upto date and dielectric strength more than 60 KV. The temprature more than 40 degree centigrade to ambient temp 40 degree centigrade when measured with resistance method for transformer winding and and 35 degree centigrade when measured by thermometer for top oil when tested in accordance with IS 2026 (Part 2). Transformer shall be painted with PU paint as per relevant IS standard. (b) (i) Rating and diagram plate will contain all terminal specifications as per IS 1180 Part-1 (ii) Earthing terminals 2 No (iii) Lifting lugs (iv) Thermometer pocket
(v). Air release device (vi). Tap changer with locking provision (vii). Oil & winding temprature indicator (viii) Dehydrating breather fitted with silica gel. (ix) Drain cum simpling valve (3/4 nominal size thread IS 554 steel with plug. (x) Pressure relief device on explosive (xi) Conservator vent. (c) Energy efficiency shall be level III as per IS-1180 amended upto date. Note : Drawing of transformer shall be got approved from GE.
Supply, installation, testing and commissioning of step down, transformer 11KV/433 Volts 3 Phase 50 HZ 63 KVA out door type, with off load tap changing arrangement on HT side to vary secondary voltage up to + 5 % to - 5 % in step of 2.5 % including suitable cable entry boxes both on HT to upto 120 sqmm 3 core XLPE cable and on low voltage side to accomodate XLPE cable of size upto 120 sqmm 3.5 core complete in all respect with standard accessories and fitment confirming to IS-1180 Part -I of 2014 amended upto date .Primary side delta (HT) and secondary side star with neutral (LT) i.e Vector diagram Dyn-11. The sailent feature of transformer shall be as follows :-
(a). Transformer shall be oil immerse, ON AN cooled, double coppper wound, core type with radiater cooled tank complete with first fill of transformer oil as per IS 335 amended upto date and dielectric strength more than 60 KV with cooling system. The temprature more than 40 degree centigrade to ambient temp 40 degree centigrade when measured with resistance method for transformer winding and 35 degree centigrade when measured by thermometer for top oil when tested in accordance with IS 2026 (Part 2). Transformer shall be painted with PU paint as per relevant IS standard (b). (i) Rating and diagram plate will contain all terminal specifications as per IS 1180 (Part 1). (ii). Earthing terminals 02 Nos (iii). Lifting lugs (iv). Thermometer pocket
(v). Air release device (vi). Tap changer with locking provision (vii). Oil & winding temprature indicator (viii) Dehydrating breather fitted with silica gel. (ix) Drain cum simpling valve 3"/4 nominal size thread IS 554 steel with plug. (x) Pressure relief device on explosion. (xi) Conservator vent. (c) Energy efficiency shall be level III as per IS-1180 amended upto date. Note :- Drawing of transformer shall be got approved from GE.
Supply, installation, testing and commissioning of step down, transformer 11KV/433 Volts 3 Phase 50 HZ 100 KVA out door type, with off load tap changing arrangement on HT side to vary secondary voltage up to +5 % to -5 % of in steps of 2.5 % including suitable cable entry boxes both on HT to receive upto 120 sqmm 3 core XLPE cable and on low voltage side to accomodate XLPE cable of size upto 120 sqmm 3.5 core complete in all respect with standard accessories and fitment confirming to IS-1180 Part -I of 2014 amended upto date .Primary side delta (HT) and secondary side star with neutral (LT) i.e Vector diagram Dyn-11 .The sailent feature of transformer shall be as follows :-
(a). Transformer shall be oil immerse, ON AN cooled, double coppper wound, core type with radiater cooled tank complete with first fill of transformer oil as per IS 335 amended upto date and dielectric strength more than 60 KV with cooling system. The temprature more than 40 degree centigrade to ambient temp 40 degree centigrade when measured with resistance method for transformer winding and 35 degree centigrade when measured by thermometer for top oil when tested in accordance with IS 2026 (Part 2). Transformer shall be painted with PU paint as per relevant IS standard (b). (i) Rating and diagram plate will contain all terminal specifications as per IS 1180 (Part 1). (ii). Earthing terminals 2 No (iii). Lifting lugs
(iv). Thermometer pocket (v). Air release device (vi). Tap changer with locking provision (vii). Oil & winding temprature indicator (viii) Dehydrating breather fitted with silica gel. (ix) Drain cum simpling valve 3"/4 nominal size thread IS 554 steel with plug. (x) Pressure relief device on explosion. (xi) Conservator vent. (c) Energy efficiency shall be level III as per IS-1180 amended upto date. Note :- Drawing of transformer shall be got approved from GE.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium stranded conductor, 11 KV Earthed, grade cross sectional area 95 Sqmm x 3 core confirming to IS-7098 amended upto date complete all as specified and directed.
XLPE insulated, screened,PVC bedded,galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium stranded conductor, 11 KV Earthed, grade cross sectional area 120 Sqmm x 3 core confirming to IS-7098 amended upto date complete all as specified and directed.
Supply , laying, jointing & testing XLPE insulated screen PVC bedded. Galvanized steel strip of wire armoured electric power cable (heavy duty) with standard aluminium conductor, 1100 volts grade of size 35 Sqmm 3.5 Core laid on wall/ floor/ underground or in air with saddle and gutties, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 95 sqmm x 3.5 Core confirming to IS-7098 amended upto date complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 120 sqmm x 3.5 Core confirming to IS-7098 amended upto date complete all as specified and directed.
Cable jointing kit for 11KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sqmm, all as specified and directed.
Cable jointing kit for 11KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 Sqmm, all as specified and directed.
Taking down and re-fixing of air break gang operated switches vertical / horizontal mounted at new location / Deposted to MES yard including insulators and operating mechanism complete all as specified and directed.
Supply and install Air Conditioner Hi wall Split units Indoor / Outdoor Hot and Cold complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating EER 3.2, copper connecting pipes of length upto oudoor unit including outdoor unit mounting on bracket making holes in wall and making good, of capacity 1.5 TR complete all as specified and as directed.
Sub Total i.e. Total of Schedule 'A' Part-XI i.e. Serial Item No 11.01 to 11.21
N K BUILDERS
R K BUILDERS
M/S VED PARKASH GUPTA
PARBAT AND SONS
Bidder Name
PARBAT AND SONS
M/S VED PARKASH GUPTA
N K BUILDERS
Electromechanics Engineers & Contractors
R K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .