Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹11.2 L+₹47,908.24 (4.45%)Rejected-Finance | L2 | Rejected-Finance Not responsive |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
13 Oct 2020, 5:00 pmClosed
Executive Engineer
CCS HAU, Hisar
Extension of area of Agri. Business Incubation Centre (ABIC) in the premises of Gandhi Bhawan at CCS HAU, Hisar (construction of stair case, covered verandah as display area at ground and first floor etc.) (including PH and EI works)
2020_HRY_146487_1
3170-C
Open Tender
Civil Works
Works
120 days
CCS HAU HISAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Executive Engineer C2
₹17,000
12 Nov 2020
30 Sept 2020
15 Oct 2020
30 Sept 2020
13 Oct 2020
30 Sept 2020
Amount
Civil work 1 to 47:- Earth work in excavation in foundations, trenches, etc .in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches ,stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres (HSR 6.6)
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth.(HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level {HSR 10.59) Ist storey
2nd storey {HSR 10.59+note)
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects. {HSR 10.82) Ist storey
2nd storey {HSR 10.82+note)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects (HSR 10.86) Ist storey
2nd storey (HSR 10.86+note)
Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 {HSR 10.95(a)}
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with 2 coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded (HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth (HSR 11.2)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7) (i) Ist storye
(ii) 2nd storey (HSR 11.7+ note)
(iii) 3rd storey (HSR 11.7+ note)
11.43 cm thick brick wall with every fourth course reinforced with hoop-iron laid in 1:4 cement stone dust (from crusher) mortar in superstructure (HSR 11.51)
Supplying and fixing in position G.I.pipe class 'B' spouts in chajjas and cantilevers. (13.55 (e) (e) 50 mm internal dia, G.I. pipe
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round gavanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvazied mild steel item (galvanizedd @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre of centre along main 'T'. The suystem should rest on periphery walls/partitions with the heop of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling (HSR 14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4)
Kotah stone 20 mm thick in skirting risers of steps, dados pillars and wall facing(lining) in any pattern as specified 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66) (Note: The skirting shall be finished with granite polish and nothing shall be paid extra). (i) Ist storye
(ii) 2nd storye
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in flooring laid in any patterns as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles {HSR 14.89} Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in skirting / dado laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles {HSR 14.90} Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
12 mm thick cement plaster 1:6 on walls (HSR 15.7+ note) Ist storey
12 mm thick cement plaster 1:6 on walls (HSR 15.7+ note) 2nd storey
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12+ note) Ist storey
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12+ note) 2nd storey
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52+ note) Ist storey
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52+ note) 2nd storey
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Providing two coats of exterior acrylic emulsion paint (HSR 16.79 (a) (a) 2nd quality
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS;733 and IS; 1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminium sections shall be smooth rust free straight mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling C.P. brass/ stainless steel screws, all complete. (HSR 17.95) Fixed portion (Anodized Aluminium transparent or dyed to required shade according to IS;1868, minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS; 733 and IS;1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including clear angle, Aluminium snap beading for glazing/ paneling C.P. brass/ stainless steel screws, etc. complete. (HSR 17.96) Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including of cost of PVC/ neoprene gasket required including Aluminium fitting.
Providing and fixing 12 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS;12823 grade I type II in paneling fixed in aluminium doors. Windows shutters and partition frames with CP brass/ stainless steel screws etc. complete. (HSR 17.97(b)} (b) Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, windows, ventilator shutter and partitions etc. with PVC/ neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items). {HSR 17.98(b)} (b) With float glass panes of 5.00 mm thickness.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS; 6315 marked for doors including cost of cutting floors as required embedding in floors and cover plats with brass pivot and single piece M.S. sheet outer box. (HSR 17.99 (a)} (a) With Stainless Steel cover plate.
Providing fixing aluminium round shape handle of outer dia 100 mm with screws etc. complete. {HSR 17.102(i)} (i) Anodized (AC-15) Aluminium.
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Earth filling under floors with dune sand (tiba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete (NS)
Providing and fixing MS tube of size 25 mm x 25 mm of 14 guage for making frame at all height for puf roof panels (excluding cost of puf roof panels) including cutting welding etc., complete in all respect as directed by Engineering In-charge. (NS)
Providing and fixing stainless steel stair case railing of 304 grade consisting of stainless steel tube as hand rail, internal members (horizontal/vertical) of required size incluidng cutting, welding, grinding, buffering etc.complete in all respect as pere architectural drawing and design. (NS)
Providing and fixing 60 mm thick (thickness at the corrugation section shall be in addition to 60 mm) sandwich PUF roof panels consisting of 0.60 mm thick high strength galvanized colour coated steel sheets on top side having trapezoidal profiles of approved make (I.S.I. mark) & bottom sheet of 0.5 mm thick high strength galvanized colour coated steel sheets (TATA make sheets should have been used in this product) and rigid polyurethane foam in between both sheets to achieve 60 mm thickness of panel, in roofing, at all height, fixed in position with self drilling screws of approved shape and make, complete in all respects as per drawing & manufacture’s specifications and instruction of Engineer-in-Charge (NS)
Providing and fixing 3 mm thick wooden shade/texture aluminium composite panel (ACP) of Alstone make of approved colour fixed on aluminium tube frame of size 25 mm x 38 mm x 2 mm @ 2’ C/C Horizontal/vertical including cost of cutting, nails, screws, sealent, tape etc. complete in all respect as directed by Engineer In-charge. (NS)
PH work 48 to 65:- Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. {HSR 28.18(b) (i)} INCLUDING COST OF SPECIALS (i) 15 mm internal diameter of pipe line
(v) 40 mm internal diameter of pipe line {HSR 28.18(b) (v)}
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. {HSR 28.21 (a)} (a) 15 mm internal diameter
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. (HSR 28.29 (a) (a) 15 mm dia
Making connection with the existing G.I branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 28.34)
Providing and fixing in position 15 mm i/d C.P brass bib cocks of best quality ( as required by the Engineer-in-charge) {HSR 30.75) (a) Bib cock long body
Providing and fixing H.C.I. floor traps I.S.I. marked of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under the around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc., minimum depth of water should be 150 mm with a minimum seal of 50 mm {HSR 30.89(b)} (b) With 75 mm internal dia outlet
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm X 150 mm cast iron cover weighing approximately 7.26 kg. and frame clear opening 300 mm X 300 mm and outside size 330 mm X 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:8:16 in foundations, and cement concrete 1:2:4 in coping around C.I. cover and frame et. With three coats of black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm {HSR 30.114(b)} (b) 100 mm internal diameter H.C.I. gully trap
Supply of GI pipe 'B' Class ISI Marked Ravindra/Jindal/Parkash(Surya) Make. (NS) (i)15 mm i/d
Supply of GI Union Couplings of UNIK/UNCO make . (NS) (i)15 mm i/d
Supply of Gun Metal Peet Valve ISI Marked of DRP/Leader/Bajaj make (NS) (a) 15 mm i/d
Supply of PVC pipe 6 kg/cm2 pressure 50 mm outer dia (1½" i/dia) Make:- Prince/Supreme/Skipper/Finolex (NS)
Supply and fixing of PVC flexible waste pipe 40 mm i/dia approximate 3' long along with PVC coupler of best quality, complet in all respect. (NS)
Supply and fixing in position stainless steel sink made of 1 mm thick Salem stainless steel sheet along with fittings of Blue Star/ Jayna make or equivalent as per AISI 304 (18/8), complete in all respect. (NS) Bowl size = 560 mm x 405 mm x 178 mm Overall size = 610 mm x 460 mm x 178 mm
Providing and installing split type air conditioners, four star rating inverter type with copper coils 1.5 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (NS) (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1000 cum/ hr. (iii) Sound level (H/M/L)- 45/38/26(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Toshiba/Mitsubishi (Heavy Industries) (four star rating) Model as approved by the Engineer-in-Charge
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 12.7 mm(½") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
EI work 66 to 93:- Supply and erection of blanking sheet in existing distribution board (HSR 31.16)
MINIATURE CIRCUIT BREAKER AND ISOLATOR:{HSR 31.17 (a) (ii)} Supply and erection of miniature circuit breaker/isolator 240/415 V in the existing distribution board including making necessary connections (a) Miniature Circuit Breakers of 9 K.A. breaking capacity (ii)6-32 amp. SP MCB
(ii) 32 amp. SPN MCB {HSR 31.17 (a) (ii)}
(iii) 63 amp. TPN MCB {HSR 31.17 (a) (iii)}
PIPE LAYING: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required :-{HSR 31.21(xv)} (xv) Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on surface
(xvi) Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness on surface {HSR 31.21 (xvi)}
(xxi) Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on flushed. {HSR 31.21 (xxi)}
(xxii) Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness on flushed. {HSR 31.21 (xxii)}
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe {HSR 31.40(i)} (i) Size 1.5 sqmm(3/0.81mm)
(ii) Size 2.5 sqmm (3/1.05mm) {HSR 31.40 (ii)}
(iii) Size 4 sqmm(7/0.85mm) {HSR 31.40 (iii)}
(v) Cable size 10 sqmm(7/1.35mm) {HSR 31.40 (v)}
S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. Recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer-in-charge of the work {HSR 31.41(ii)} (ii) 8-way, SP&N (Horizontal)
(vi) 8-way, TP&N (Horizontal) (8+24) {HSR 31.41 (vi)}
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 31.56) 10 amp. 1 way switch
10 amp. 2 way switch (HSR 31.56)
20 amp. Switch (HSR 31.56)
10 amp. Socket (HSR 31.56)
16 amp. Socket (HSR 31.56)
Fan regulator (HSR 31.56)
Blinking plate (HSR 31.56)
Pdg. and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 31.57) 1 & 2 Modules
3 Modules (HSR 31.57)
6 Modules (HSR 31.57)
12 Modules (HSR 31.57)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. i) 1400mm sweep (56") Make: Usha, Orient, Crompton. (NS)
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5600K to 6500K), Power factor >0.95, CRI (Ra) >80, LED Lamp efficiency ≥ 140 lm/w, Average life > 50000 hours, complete with all accessories as required with connections (Industrial) Make: Havells, Philips, Wipro, Bajaj (NS)
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena
M/s sukhdev and company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .