Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.6 L+₹6,365 (2.49%)Rejected-Finance PRIME COMPUTERS TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR | MANDAMPUR | MANDAMPUR | HARYANA | 125052 | L2 | Rejected-Finance L2 |
Tender Value
₹2.1 L
EMD Value
₹4,143
Closing Date
19 Sept 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Elect. Div PWD B and R Hisar
Executive Engineer Elect. Div PWD B and R Hisar
Construction of Camp Office in Deputy Commissioners
2022_HRY_238834_1
202213BB45AE F4AF 4110 9D8A 1F3FAF38462F666BAR
Open Tender
Electrical Works
Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
₹4,143
Yes
6 Dec 2022
13 Sept 2022
20 Sept 2022
13 Sept 2022
19 Sept 2022
13 Sept 2022
60 days
Amount
NS Item -S/E of indoor commercial recessed mounted LED panel 2`X2` of 36 W of Havel`s make Model No. PLANO2X2PLR36W LED B65S with Fixture size 595x595x65mm, Invative direct/ indirect luminaire suitable for armstrong/ Grid ceiling with high brightness LEDs and conical deglaring center panel for effecient downlight completed including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.
Supply of 12` (300mm) Exhaust fan of Bajaj/Havells/Orient make complete with all accessories the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work.
Supply of LT Power Ard. Cables of Aluminum Conductor complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Size 25 Sqmm 3.5 Core Cable (Ard)
NS Item -S/E of 45 W 5700K LED Street light fitting made up of pressure die cast aluminum housing with acrylic cover as diffuser with IP66 protection LED of Make :- Phillips/Wipro/Bajaj/Havells including the all petty material and labour for errection, complete in all respect of upto the entire satisfaction of the Engineer-in-Charge of the work
NS Item -Supply of 20 W LED Batten light fitting Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination of Make :- Phillips/ Wipro/ Bajaj/ Havells including the all petty material and labour for errection, complete in all respect of upto the entire satisfaction of the Engineer-in-Charge of the work
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.(HSR 23.3.6) 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1)
Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.(HSR 23.4.1) Group A (HSR 23.4.1.1)
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required. (HSR 23.4.4) Group A (HSR 23.4.4.1)
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required. (HSR 23.4.5) Group A (HSR 23.4.5.1)
EARTHING AND LIGHTENING ARRESTOR (HSR 24.1) Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.(HSR 24.1.1)
Extra for using salt and char coal/coke for pipe earth electrode as required.(HSR 24.1.2)
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.(HSR 24.1.11)
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop carthing as required.(HSR 24.1.13)
Laying of underground cable 0.75 metre below ground level covered without sand and bricks including excavation and refilling of trenches.:-(HSR 24.2.3) 16 Sq mm to 35 sqmm 2 to 4 Core (HSR 24.2.3.2)
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. (HSR 23.5.6) 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.3)
Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. (HSR 24.4.3)
Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A bakellite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on bakellite sheet in the M.S. box including painting and necessary connections.( HSR 24.4.5)
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.(HSR 23.7.6) PVC pipe of 25 mm dia. (HSR 23.7.6.2)
Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.(HSR 23.8.4)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSr 23.8.10) 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1)
12 Modules (HSR 23.8.10.6)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11) 5 amp 1 way switch (HSR 23.8.11.1)
15 amp 1 way switch (HSR 23.8.11.3)
5 amp Socket (HSR 23.8.11.4)
15 amp 6 pin Socket (HSR 23.8.11.5)
Telephone Socket outlet modular type (HSR 23.8.11.8)
RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11)
Erection of Exhaust fan in existing opening, complete with necessary earthing of Fan including carriage from PWD store to the site of work. (HSR 23.9)
Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required. (HSR 23.12)
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.(HSR 23.20)
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.(HSR 23.22.1) TRIPLE POLE MCCB 16 to 100 Amp (HSR 23.22.1.3)
MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings. (HSR 23.22.2) MCCB up to 125 A FP (HSR 23.22.2.1)
Supply and erection of double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 23.22.4) i) TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) (HSR 23.22.4.6)
Supply and erection of miniature circuit breaker 240/ 415 V in the existing distribution board including making necessary connections (HSR 23.22.5) i) 6 Amp. to 32 Amp. Single Pole (HSR 23.22.5.1)
40 amp to 63 amp. MCB's FOUR POLE. (HSR 23.22.5.8)
Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):-(23.23.1) Size 25 mm dia (23.23.1.3)
Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required.(23.23.2) 15 mm dia (23.23.2.1)
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work.(HSr 23.23.8) 4 pair telephone wire (HSR 23.23.8.2)
Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVc conduit as required (HSR 23.23.9)
Supply, Erection, Testing of Ceiling Fan IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-Charge (HSR 20.71) 48" (1200 mm) (HSR 20.71.1)
Prime Computers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .