| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | L1 | Accepted-AOC AS L-1 BIDDER | |
| 2 | L2₹25.3 L+₹2.3 L (9.82%)Rejected-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | L2 | Rejected-Finance AS L2 BIDDER |
| Sl No | Description | Qty | Unit | Selwel Commotrade Private Limited L1 | CIS GLOBAL INFRATECH PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. | |||||
| 1.10 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 1 | cum | 2,500 ₹2,500 | 2,435 ₹2,435 Lowest |
| 2.00 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | 1 | cum | 1,000 ₹1,000 Lowest | 3,550 ₹3,550 |
| 3.00Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : | |||||
| 3.10 | Of area 3 sq. metres and below | 3 | each | 250 ₹750 Lowest | 600 ₹1,800 |
| 4.00 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. | 1 | each | 650 ₹650 | 600 ₹600 Lowest |
| 5.00 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | 103 | sqm | 65 ₹6,695 | 60 ₹6,180 Lowest |
| 6.00Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. | |||||
| 6.10 | In cement mortar | 4 | cum | 1,500 ₹6,000 Lowest | 2,060 ₹8,240 |
| 7.00Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : | |||||
Tender Value
₹25.3 L
EMD Value
₹50,700
Closing Date
1 Oct 2025, 4:00 pmClosed
HEAD, ESU
ENGINEERING SERVICES DEPARTMENT, CSIR-CGCRI, KOLKATA
Civil and Electrical repairing and renovation work of store room, presently used as a store for old scrap materials beside canteen, for the installation of new MCVD setup, FOPD at CSIR-CGCRI, Kolkata
2025_CSIR_248854_1
GCW/CE/06/25-26(W)
Open Tender
Civil Works
Works
90 days
CSIR-CGCRI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
CENTRAL GLASS AND CERAMIC RESEARCH INSTITUTE
₹50,700
11 Dec 2025
16 Sept 2025
2 Oct 2025
16 Sept 2025
1 Oct 2025
16 Sept 2025
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Neat cement punning.
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:4 (1 cement: 4 fine sand)
1:6 (1 cement: 6 fine sand)
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:4 (1 cement: 4 fine sand)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete to acheve given shade and colour:
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On concrete work
White washing with lime to give an even shade :
New work (three or more coats)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Wall panelling / partition with Interior quality Aluminium Composite Panel (ACP) of approved make and brand as per direction of Engineer - in -Charge excluding the cost of supporting frame work at any floor and any height. 4mm thick
Supplying, fitting and fixing PUF Insulated sandwich 60 mm thick continuous wall/roof panels having PUR (density 40 ± 2 kg/cum & self extinguishing) conforming to IS:12436-1988 as core material with pre painted Galvanised sheet conforming to IS:14246-1995 of minimum thickness 0.5mm & minimum yield stress 240 MPa with Zinc coating of minimum 120 gsm as per IS:277-1992 as skin on both faces affixed by self-bonding to generate minimum adhesive strength (foam to steel) 2.9 kg/cm 2 duly protected by 5-7 micron epoxy primer on both faces & polyester top coat of 15- 18 micron and shall be vertically joined together by tongue & groove joints & cam locks spaced @ 1m c/c along the joints to form a continuous wall or ceiling and fixed by self-tapping GI screws with requisite length & number to the peripheral frame through 'Ú' tracks/ rivets etc complete in all respects as per direction of the Engineer-in-Charge. 60 mm thickness
Single leaf PUF panel door size 1.0m x 2.0 m : Providing and fixing minimum 60 mm thick factory made solid PUF (Poly Urethene Foam) core door shutter shall consists of periferial frame made out of Aluminium frame or equivalent. The size of the frame as per require for matching with 60 mm PUF wall/ceiling. The core panels shall having PUR (density 40 ± 2 kg/cum & self extinguishing) conforming to IS:12436-1988 as core material with pre painted Galvanised sheet conforming to IS:14246-1995 of minimum thickness 0.5mm & minimum yield stress 240 MPa with Zinc coating of minimum 120 gsm as per IS:277-1992 as skin on both faces affixed by self-bonding to generate minimum adhesive strength (foam to steel) 2.9 kg/cm 2 duly protected by 5-7 micron epoxy primer on both faces & polyester top coat of 15- 18 micron Matt/Plain finish. Single pices extruded Puf insulated door shutter including locking arrangement & door closure, all complete as per direction of Engineer-In-Charge.
Double leaf PUF panel door size 3.0m x 2.1 m : Providing and fixing minimum 60 mm thick factory made solid PUF (Poly Urethene Foam) core door shutter shall consists of periferial frame made out of Aluminium frame or equivalent. The size of the frame as per require for matching with 60 mm PUF wall/ceiling. The core panels shall having PUR (density 40 ± 2 kg/cum & self extinguishing) conforming to IS:12436-1988 as core material with pre painted Galvanised sheet conforming to IS:14246-1995 of minimum thickness 0.5mm & minimum yield stress 240 MPa with Zinc coating of minimum 120 gsm as per IS:277-1992 as skin on both faces affixed by self-bonding to generate minimum adhesive strength (foam to steel) 2.9 kg/cm 2 duly protected by 5-7 micron epoxy primer on both faces & polyester top coat of 15- 18 micron Matt/Plain finish. Single pices extruded Puf insulated door shutter including locking arrangement & door closure, all complete as per direction of Engineer-In-Charge.
Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
Godrej Hydraulic door closer fitted and fixed complete. Heavy type
Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including mending good damages and finishing the surface to match with adjacent areas complete as per direction. With reinforced cement concrete blocks (1:1½:3) with stone chips and nominal reinforcement. Block size 250 x 125 x 75 mm.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
6 x 4 sq.mm
2 x 6.0 sq. mm (Green colour)
Supplying and drawing following pair 0.5 sq mm FRLSPVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
1 run of cable
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Triple pole & Neutral
Supply, installation of following metal enclosure for MCB
Four pole
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A,30KA,FPMCCB
125 A,36KA,FPMCCB
Providing and fixing following rating MCCB Metal enclosure in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A,30KA,FPMCCB
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X35 sq. mm (25mm)
Finishing of end termination with proper size of pin / ring type copper solderless socket by crimping method of following sizes PVC insulated copper conductor
1 x 2.5 sq. mm
1 x 4 sq.mm
Supply of the following Items make as per attached sheet:-
Modular type RJ 45 I/O socket for CAT 6
Supply of 1.1 KV grade following PVC insulated Armoured cable confirming the IS 7098 (Part 1) 1988 specification:-
4 Core 35 sq.mm. copper cable
Supply & fixing of of following indoor type LED Light fittings with extra high efficiency 120-150 lumens/watt LEDs. The fixture must have of CRI > 80, Colour temperature 6000K/6500K and weather & dust proof with 2 years warranty.
36 Watt 595 mm x 595 mm recess mounted
Supply, installation, testing & commissioning (Maximum star rated) Air Cooled Ductable AC system with copper cooling coil and copper condensor coil and R-410A/R32 refrigerent gas and with Hermetically sealed compressor, thermostatic expansion valve and microprocessor controlled Remote switch. The job is including of electrical cabling work for power distribution, cutting holes, supply and mounting MS section on the brick pedestal / outdoor MS structure for the out door units with Plasma / filters, necessary mounting arrangement for indoor units comprising supports, leak testing & adequate gas charging etc.Installation of MS Structure,Canvas Connection,Aluminium Diffuser.
5.5 TR Ductable Type.
Supply & interconnecting refrigerant piping for liquid & discharge line, insulation, supports, brackets etc. between indoor and out door unit in surface / recess fashion as per site requirement with Communication cable,Duct installation,along with drain piping work.
5.5 TR Ductable Type.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 35 sq. mm (32mm)
CIS GLOBAL INFRATECH PRIVATE LIMITED (BID ID -903037)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .