Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.0 L+₹1.0 L (3.15%)Rejected-Finance | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹33.6 L+₹1.6 L (4.89%)Rejected-Finance 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L3 | Rejected-Finance Being lowest tenderer | |
| 4 | L4₹47.2 L+₹15.2 L (47.6%)Rejected-Finance | L4 | Rejected-Finance Being not lowest tenderer | |
| 5 | Rejected-Technical | - | Rejected-Technical Not admitted due to bid withdrawn by bidder |
| Sl No | Description | Qty | Unit | M/S Delhi Engineering Co. L2 | Neeraj Enterprises L3 | M/S S.K.Electricals L4 | Deepak Electricals L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles, struts, stays etc and getting out complete all as specified and directed by Engr-in-Charge. | 141 | Cum | 70 ₹9,870 Lowest | 383 ₹54,003 | 150 ₹21,150 | 130 ₹18,330 |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete all as specified and directed by Engr-in-Charge. | 92 | Cum | 10 ₹920 Lowest | 320 ₹29,440 | 100 ₹9,200 | 50 ₹4,600 |
| 3.00 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engr-in-Charge. | 49 | Cum | 10 ₹490 Lowest | 139 ₹6,811 | 100 ₹4,900 | 50 ₹2,450 |
| 4.00 | Supply and Spread Natural Riddled soil in trenches for cushioning and covering to cable complete all as specified and directed by Engr-in-Charge.
Note: (i) Natural soil shall be riddled by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 cm and 15cm after laying of cable. This is then gently punned down to a depth of 10cm above the top of upper-most cable. (ii) For the purpose of measurement only punned thickness only will be considered for payment. | 60 | Cum | 300 ₹18,000 Lowest | 500 ₹30,000 | 500 ₹30,000 | 400 ₹24,000 |
| 5.00 | M&L for laying in trenches precast concrete cable covers Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified and directed by Engr-in-Charge. | 5,400 | Each | 20 ₹1,08,000 | 10 ₹54,000 Lowest | 55 ₹2,97,000 | 15 ₹81,000 |
| 6.00 | Dismantling U/S any size of cross arms from pole /structures and fencing post, struts etc. complete all as specified and directed by Engr-in-Charge. | 0.5 | Qtl | 1,000 ₹500 | 130 ₹65 Lowest | 1,000 ₹500 | 500 ₹250 |
| 7.00 | M&L for work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer complete all as specified and directed by Engr-in-Charge. | 0.5 | Qtl | 20,000 ₹10,000 | 11,931 ₹5,965.5 | 15,000 ₹7,500 | 8,000 ₹4,000 Lowest |
| 8.00 | M&L for boring hole under road/pavement/hard standing by trenchless technology using ultrasound technique & necessary machine for inserting DWC HDPE of pipe 150 mm size dia. DWC HDPE to be included in the quoted rate complete all as specified and directed by Engr-in-Charge. | 18 | RM | 350 ₹6,300 Lowest | 500 ₹9,000 | 600 ₹10,800 | 400 ₹7,200 |
| 9.00 | Supply & laying of UG cable XLPE insulated armored heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 400 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts etc including taking out of existing unserviceable cable of any size and description including removing/taking out damaged XLPE cable complete all as specified and directed by Engr-in-Charge. Note: Excavation and earthwork will be measured and paid separately | 90 | RM | 1,100 ₹99,000 | 1,800 ₹1,62,000 | 1,600 ₹1,44,000 | 600 ₹54,000 Lowest |
| 10.00 | All as per item No. 9 above but of cross sectional area 240 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge. | 200 | RM | 900 ₹1,80,000 | 1,168 ₹2,33,600 | 1,400 ₹2,80,000 | 600 ₹1,20,000 Lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
9 Jul 2025, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/REPLACEMENT OF UG CABLE, CIRCUIT BREAKER, LT PANEL BOARD, CAPACITOR BANK, SWITCH AND MISC ELECTRICAL WORK INCLUDING DG SET REPAIR AT BRD, AF UNDER GE (AF) TUGHLAKABAD
2025_MES_713576_1
GE/TKD-31/2025-26
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹0
₹66,000
Yes
11 Feb 2026
11 Jun 2025
11 Jul 2025
11 Jun 2025
9 Jul 2025
26 Jun 2025
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .