Loading…
Loading…
Tender Value
₹80.8 L
EMD Value
₹1.6 L
Closing Date
7 Jul 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of GCC 2022 (Form-6 of the instant tender document), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note:- Similar nature of work - "Supply, Installation & Commissioning of Data Logger or RTUs OR Any Signal Interlocking Works involving EI OR RRI or PI OR IBS OR IBH OR LC Gate Interlocking OR Yard Modification OR UFSBI OR Track Circuit (AFTC OR DC TC) OR Axle Counter (SSDAC OR MSDAC OR HA- SSDAC)OR Automatic Signalling". to be considered as similar nature of work for the instant tender work.
14 conditions · 6 needing a document upload
The participant tenderers are requested to submit the following general information:- (i) The list of personnel / organization on hand and proposed to be engaged for the tendered work vide Annexure - AI. (ii) List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work vide Annexure - AII. (iii) List of works carried out in the past vide Annexure-AIII. (Note :- Certificates and testimonials regarding contracting experience for the type of job for which tender is invited along with certificates which may be an attested Certificate from the client, Audited Balance Sheet duly certified by the Chartered Accountant etc regarding contractual payments received in the past, please be submitted along with the offer). (iv) Details of work with the tenderer presently on hand vide Annexure - AIV. (v) Declaration regarding association of Railway Officers/Engineers with the tenderer vide Annexure- AV. (vi) List of court cases of the tenderer during last five years vide Annexure - AVI. (vii) List of arbitration cases of the tenderer during last five years vide Annexure - AVII. (viii) The participant tenderer should upload the tender document (1st sheet & 2nd sheet duly filled in and signed).
(i) A copy of document verification certificate stating that they are not liable to be disqualified and all their statements/documents submitted along with bid are true and factual. Standard format of the certificate mandatorily to be submitted by the bidder is enclosed as Annexure- B (Annexure-V of GCC) in the tender document. NOTE:- Non submission of a copy of certificate duly filled and signed vide Annexure-B of tender document/online submission of Annexure-V of GCC in IREPS by the bidder shall result in summarily rejection of his/their bid . (ii) Format for another document verification certificate mandatorily to be submitted/ uploaded by attorney/authorized signatory/each member of a Partnership Firm / Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. as the case may be vide Annexure-D in tender document/ prescribed format available in IREPS (Annexure-VA of GCC). Note: Non submission of a copy of certificate duly filled and signed (vide Annexure- D in the tender document/Annexure-VA of GCC) by the bidder as stated in tender document/IREPS shall result in summarily rejection of his/their bid.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Make in India Policy:- Provisions of Make in India Policy 2017 issued by Govt. of India, as amended from time to time, shall be followed for consideration of tenders.
The terms and conditions in details along with additional information relating to this e-Tender, the tender document uploaded herewith is to be referred.
The firm should read the various conditions to tender document attached hereto and agree to abide by the said conditions.
The provision of General Condition of Contract (G.C.C. April-2022 with upto date correction slips) for works as amended from time to time, will govern this contract and the firm should agree to abide by the Indian Railway's said standard General Conditions of Contract.
Once the tender is awarded, none of these aspects can be denied or disputed under any circumstances, otherwise necessary action will be taken as per terms & conditions of the Tender. All the installaton item should be installed only by OEMs or OEM authorized Firm.
Warranty/ Guarantee of 30 months shall be ensured for schedule item no. 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 36, 37, 38, 39, 40, 41 & 54 of Schedule 'B' from the date of supply of materials to the railway store .Twelve Months Warranty/ Guarantee shall be ensured for all rest of the schedule items for supply and workmanship from the date of completion of the work. During the guarantee period the contractor shall be responsible for any repairs/ replacement of any defective installation free of cost.
For any further queries, you can mail to our official mail ID: [email protected]
Patch repairing work in the section of KOAA-Circular-MJT-KBGB section of Sealdah division.
SDSTE-Sig-T-04-26-27-RRSK~ER
SDSTE-Sig-T-04-26-27-RRSK
Open
Works - General
9 Months
Kolkata, West Bengal
₹0
₹1.6 L
7 Jul 2026
10 Jun 2026
23 Jun 2026
117 items across 3 schedules · ₹80,82,877.32 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Shifting/lifting of location box to facilitate earthwork of Engg/Con.This includes filling with sand and plastering inside location box. Note : All the materials like Sand ,Cement etc. will be supplied by the contractor." | Numbers | 5.00 | 2,338.14 | 11,690.7 |
| 2 | "Supply of full size apparatus case (Large) (as per DRAWING NO. SW SK NO. 4/90 & other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No. will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S- 11500. Inspection : Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS " | Numbers | 5.00 | 11,793.22 | 58,966.1 |
| 3 | "Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for Full size Apparatus Case with termination & Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. Inspection : Consignee" | Numbers | 5.00 | 4,093.22 | 20,466.1 |
| 4 | "Supply of paper base hylam sheet 12 mm thick. Inspection: consignee." | Sqm | 5.00 | 4,550.85 | 22,754.25 |
| 5 | "Supply of PBT ARA terminal, 6 WAY, DRG. No. 23756, ALT-3. as per IRS Spec. No. IRS: S-75-2006(REV-2) or Latest. Material to be procured from RDSO's approved firm only. Inspection: RDSO. " | Numbers | 100.00 | 411.02 | 41,102 |
| 6 | "Supply of fuse block (PBT) to spec.no.IRS-S- 75/2006(REV-2) OR LATEST,DRG.NO.SA- 23748 with fuse inserts cartridge, non- deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Fuse Base Inspection: -RDSO." | Numbers | 20.00 | 150.85 | 3,017 |
| 7 | "Supply of fuse block (PBT) to spec.no.IRS-S- 75/2006(REV-2) OR LATEST,DRG.NO.SA- 23748 with fuse inserts cartridge, non- deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Fuse, non- deteriorating(2A/6A/10A/16A) type, cylindrical(IRS-S-78/92) Inspection: -RDSO." | Numbers | 100.00 | 51.69 | 5,169 |
| 8 | "Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of Full size Apparatus Case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - i) Location boxes to painted with anti- corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside. ii) Location box will be supplied by Rly." | Numbers | 10.00 | 2,993.22 | 29,932.2 |
| 9 | Dismantling of location box / RCC Goomty including all its accessories & concrete foundation. | Numbers | 5.00 | 551.69 | 2,758.45 |
| 10 | "Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. Of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer. Note: Hiring of HDT machine is also included in this scope of description." | Metre | 100.00 | 1,489.83 | 1,48,983 |
| 11 | "Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/ TC/ 45/ 2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll for each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: consignee" | Kilometre | 0.20 | 53,277.12 | 10,655.42 |
| 12 | Supply of cast iron offset bracket for Main Signal with U clamps, nuts, washers complete DRG. NO. SA-23080/ADV/ALT-1. RDSO SPEC. NO. IRS-S-10/78. Inspection: consignee. Note : Offset bracket has to be connected wherever necessary as per site engineer. | Numbers | 2.00 | 2,129.66 | 4,259.32 |
| 13 | "Supply of offset bracket for position light Shunt Signal (90mm outside Dia.) post with U clamps, nuts, washers complete Inspection : Consignee subject to procurement from RDSO approved vendors " | Numbers | 2.00 | 1,729.66 | 3,459.32 |
| 14 | "Supply of magneto telephones with all accessories including supply of 2 nos. Dry cell for each telephone with wooden battery box. (i) SPEC.FOR magneto telephone - IRS- TC-79/2000.AMD-1 or latest. Inspection : Consignee" | Numbers | 2.00 | 2,973.73 | 5,947.46 |
| 15 | "Supply of V.F. Transformer 1120:600/470 :1120 as per IRS:TC-22/76 or latest. Type - Cylindrical Inspection : Consignee" | Numbers | 50.00 | 620.34 | 31,017 |
| 16 | "Supply of KEY LOCK 'E' type to Drg. No. SA- 3376/M (IRS) Alt.-2 (with latest Alt if any) and KEY to Drg. No. S-3377/M (IRS) to ward No. as per site requirement and RDSO specification No. IRS: S- 30/64 (with Amdt. up to date if any). Inspection:RDSO." | Numbers | 2.00 | 938.14 | 1,876.28 |
| 17 | "Supply of Top Plate with buttons as per requirement of Domino type of control panel suitable for domino size 54 x 34 mm.Make- Deltron Inspection: Consignee " | Numbers | 2.00 | 205.93 | 411.86 |
| 18 | "SUPPLY OF ELECTRIC KEY TRANSMITER (ROTARY TYPE) FOR L.C. GATE CONTROL/ CRANK HANDLE ARRANGEMENT AS PER SPEC. NO. IRS:S-21/2001 (REV.1) & DRG. NO. SA-22601 (ALT. 4) (OR LATEST). MATERIAL TO BE PROCURED FROM RDSO APPROVED FIRM ONLY. INSPECTION : RDSO. NOTE : THE WARD NO. OF KEY SHALL BE ADVISED BY THE RAILWAY SITE ENGINEER." | Numbers | 2.00 | 6,224.58 | 12,449.16 |
| 19 | "INSTALLATION, WIRING, TESTING & COMMISSIONING OF ELECTRIC KEY TRASMITTER FOR L.C. GATE CONTROL/ CRANK HANDLE ARRANGEMENT AS PER APPROVED DIAGRAM FOR NORMAL OPERATION AND EMERGENCY INTERLOCKED KEY (PROVIDING COVERING BOX WITH LOCKING ARRANGEMENT ON THE WALL OF GATE LODGE/ CABIN) AS PER THE INSTRUCTION OF RLY. SITE ENGINEER. ONLY ELECTRIC KEY TRANSMITER WILL BE GIVEN BY THE RAILWAY. NOTE : IN CASE OF REPLACEMENT OF ELECTRIC KEY TRASMITTER (EKT), THE ABOVE WORK ALSO INCLUDES DISMANTLING OF THE EXISTING EKT AND/OR COVERING BOX BEFORE REPLACEMENT, AND TRANSPORTATION & DEPOSITION (INCLUDING LOADING & UNLOADING) OF EKT TO THE STORE OF SSE/SIGNAL/STORE/SDAH AND/ OR AS ADVISED BY THE RAILWAY AUTHORITY." | Numbers | 2.00 | 5,759.32 | 11,518.64 |
| 20 | "Supply of Motorised boom locking set (consisting of locking arrangement for two booms) . The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Make-as per site requirement Inspection: Consignee" | Set | 1.00 | 29,252.54 | 29,252.54 |
| 21 | "Supply of Power contractor/Relay for motor 24V DC, MAKE L&T MLO/SIEMENS / SCHNEIDER or SIMILAR. The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Inspection: Consignee" | Numbers | 2.00 | 1,740.68 | 3,481.36 |
| 22 | "Supply of PMDC MOTOR 24V DC, 90W/1500RPM.The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Note:- This is along with the Pinion. Inspection: Consignee" | Numbers | 2.00 | 11,289.83 | 22,579.66 |
| 23 | "Supply of boom lock PMDC MOTOR 24V DC, 40W/1500RPM.The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Note:- This is along with the Pinion. Inspection: Consignee" | Numbers | 2.00 | 2,094.92 | 4,189.84 |
| 24 | "Supply of PUSH BUTTON with ELEMENT. The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Note:- This is along with the Push Button. Inspection: Consignee." | Numbers | 2.00 | 337.29 | 674.58 |
| 25 | "Supply of TIMING BELT(277L). The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Inspection: Consignee. " | Numbers | 4.00 | 847.46 | 3,389.84 |
| 26 | "SUPPLY OF GEAR BOX WITH CONNECTING LEVER (03 PIECES WITH BOX PIN) FOR USE IN PEDESTAL OF ELECTRICALLY OPERATED LIFTING BARRIER GATE AS PER RDSO SPECIFICATION NO. RDSO/SPN/208/2012, VER. 2.0 OR LATEST.Make- As per site requirement INSPECTION : RDSO. " | Numbers | 1.00 | 35,500 | 35,500 |
| 27 | "SUPPLY OF LIMIT SWITCH LS1 AND LS2 J02TPRA, 2NO 2NC - 1 NO. FOR GEAR BOX OF PEDESTAL, AS SPARE PARTS FOR ELECTRICALLY OPERATED LIFTING BARRIER GATE AS PER RDSO SPECIFICATION NO. RDSO/SPN/ 208/2012, VER. 2.0 OR LATEST. THIS INCLUDES DISMANTLING & RELEASING OF THE EXISTING PORTION. MAKE : BCH or SIMILAR (As per the site requirement ). Note :- Limit switches should be suit with the wirings of existing ELB . Inspection: consignee" | Numbers | 5.00 | 749 | 3,745 |
| 28 | "SUPPLY OF HEAD LOCK LIMIT SWITCH JLSLA- 2NO. 2NC. FOR MOTORIZED LOCK BOX, AS SPARE PARTS FOR ELECTRICALLY OPERATED LIFTING BARRIER GATE AS PER RDSO SPECIFICATION NO. RDSO/SPN/208/2012, VER. 2.0 OR LATEST. THIS INCLUDES DISMANTLING & RELEASING OF THE EXISTING PORTION. MAKE : BCH or SIMILAR (As per the site requirement ). Note :- Limit switches should be suit with the wirings of existing ELB . Inspection: consignee" | Numbers | 5.00 | 1,180 | 5,900 |
| 29 | " S u p p l y of complete operating and transmission system of L.C. gate right from winch machine to L.C. gate. This item includes supply of all the materials required like foundations, cranks, joints, wires, wire insulators, wheels, arc lever etc by contractor. Inspection: consignee & materials to be procured from original manufacturer or dealer." | Numbers | 1.00 | 78,228.81 | 78,228.81 |
| 30 | "Supply of boom locking arrangement complete as per DRG. NO. SA- 8158/M(ADV).1) pole lock base as per RDSO's DRG. NO.8159/M (ADV). specification no. GR.FG-200. IS-210-78. IRS-S-10.2). Pole lock cover as per RDSO'S DRG. NO. S-8160/M specification no.GR. FG200.IS-210-78. IRS-S- 10. And one set consists of one lock and one cover including all accessories as required. Material to be procured from approved list of firms for manufacturer & supply of mechanical signalling item. Inspection: Consignee " | Numbers | 1.00 | 33,493.22 | 33,493.22 |
| 31 | "Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both of any reputed make are to be supplied by Contractor. The work shall be done as per instructions of rly engineer at site and extant practice on E Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals,TLJB & Block joints if any, apparatus Cases, gate booms ,etc , Description writing , legibly and neatly inside location boxes , relay hut, gate lodge etc. - for LC Gate. Inspection: Consignee." | Lot | 2.00 | 5,540.68 | 11,081.36 |
| 32 | "Installation of Electric Point Machines (143mm stroke type/220mm stroke type- TWS) on MS plate fixed on wooden/ concrete sleepers complete with fixing of junction boxes, ground connections including smithy works involved, insulation of MS plate on which the point machine is to be fixed from the gauge tie plate involving riveting/welding of angle cleats, installation of point JB, termination adjustment for operation of points by crank handle, painting and lettering as required including wiring, testing and commissioning. Note: MS plate/flat/angle /angle cleats, paints, bolts & nuts and washers of sizes as required for fixing the point machine shall be supplied by the contractor except point machine. Note : i) Point Machine & Ground Fittings to be supplied by Rly. ii) Dismantling and refixxing of existing EPD in case of DoobleSlip/Diamond Xing" | Numbers | 10.00 | 8,819.49 | 88,194.9 |
| 33 | "Supply of Point insulation Complete set as per RDSO/SPN/168/2005 for 1.Switch bracket'D' bracket insulation for IRS point machine - One set comprises of (a)Side plate LH to Drg.No.S-3266 - 1 No. (b)Side plate RH to Drg.No.S-3265 - 1 No. (c)Insulating bush to Drg.No.S-3199 - 4 Nos.(d) Insulating washer to Drg.No.S-8640 - 4 Nos., 2.Split- Stretcher bar 2.1 Insulation for Leading stretcher bars(BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T- 10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T-10371 - 6 Nos.2.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No.T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 - 6 Nos. (c) Insulating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 - 12 Nos. 2.3 Insulation of 'L' Bracket & 3. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washereach set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T- 10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 - 6 Nos. Inspection: Consignee subject to procurement from RDSO approved vendors" | Set | 10.00 | 1,044.07 | 10,440.7 |
| 34 | Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps) with contractor's fixing material. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site | Numbers | 10.00 | 1,115.25 | 11,152.5 |
| 35 | Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post per DRG. NO. S&T/SDAH/SK- 1386 and as per standard practice. Inspection: Consignee subject to procurement from RDSO approved vendors | Numbers | 10.00 | 316.1 | 3,161 |
| 36 | "Supply and installation of P/ C / G/ A/ AG marker (size 250mm dia circle) high intensity prismatic(TYPE-IV) retro reflective sheet over 2 mm thick aluminium sheet & letter will be screen printing (250 mm dia circle) as per drg. S&T/SDAH/SK-1383 and technical specification attached. This will include cost of all materials including fixing clamp required for this work. Inspection: - Consignee" | Numbers | 10.00 | 466.1 | 4,661 |
| 37 | Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C- 42(NKG). | Numbers | 4.00 | 6,834.75 | 27,339 |
| 38 | "Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 2 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as RDSO SPEC NO. RDSO/SPN/ 151/1997 OR LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes LED signal lighting unit including current regulator. This also includes protection of unit from rain water. :- SUPPLY Inspection: Consignee" | Numbers | 1.00 | 22,527.97 | 22,527.97 |
| 39 | "Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 2 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as RDSO SPEC NO. RDSO/SPN/ 151/1997 OR LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes LED signal lighting unit including current regulator. This also includes protection of unit from rain water. Execution." | Numbers | 1.00 | 1,405.08 | 1,405.08 |
| 40 | "Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 3 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only.Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water. Execution. " | Numbers | 2.00 | 1,993.22 | 3,986.44 |
| 41 | "Installation, erection and wiring of CLS unit, post, ladder & base LED unit including laying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 3 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only.Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water. Supply Inspection: Consignee " | Numbers | 2.00 | 23,143.22 | 46,286.44 |
| 42 | "Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 4 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only.Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water.Supply. Inspection: Consignee " | Numbers | 1.00 | 26,087.29 | 26,087.29 |
| 43 | "Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 4 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only.Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water. Execution " | Numbers | 1.00 | 2,313.56 | 2,313.56 |
| 44 | "Dismantling of existing main signal including dependent shunt signal, calling on signal if any, fitted on the same post along with signal post, signal unit, ci base without damaging any part." | Numbers | 5.00 | 1,032.2 | 5,161 |
| 45 | "Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Inspection : Consignee " | Numbers | 500.00 | 46.61 | 23,305 |
| 46 | "Supply of End plate 2.5mm/0.091 in thick as per site requirement. Inspection : Consignee " | Numbers | 60.00 | 8.47 | 508.2 |
| 47 | "Supply of End Stopper 10mm/0.0394 in width as per site requirement. Inspection : Consignee " | Numbers | 60.00 | 8.47 | 508.2 |
| 48 | "Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. Inspection : Consignee" | Metre | 20.00 | 92.37 | 1,847.4 |
| 49 | "Supply of Double Wall Corrugated (DWC)- HDPE pipe/duct of size 200 mm outer dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Specn.No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part-II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-cap DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: Consignee." | Metre | 100.00 | 336.44 | 33,644 |
| 50 | Placing of DWC/HDPE/RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. | Metre | 100.00 | 26.27 | 2,627 |
| 51 | "Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee " | Per Conductor | 540.00 | 7.63 | 4,120.2 |
| 52 | "Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway is not available, 4"" of 1:2:4 concreting should be done. Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment" | cum | 360.00 | 207.63 | 74,746.8 |
| 53 | "Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometre post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Note : Cable will be supplied by Rly." | RMT | 2000.00 | 4.24 | 8,480 |
| 54 | "Supply of IPS DC-DC converter 24-32V DC, 10 Amp or 60-66 V DC, 5 Amp or 60-100V DC,1 Amp/3 Amp/5 Amp.Note: Item will be supplied as per site requirement and make of existing IPS. Inspection : RDSO" | Numbers | 5.00 | 20,636.44 | 1,03,182.2 |
| 55 | "Supply of Counter Block for control cum indication panel. Make-Deltron/Ultra or Superior. Inspection- Consignee" | Numbers | 5.00 | 1,805.93 | 9,029.65 |
| 56 | "One set of different type of panel key for domino type control cum indication panel. Make- Deltron/Ultra or Superior. Inspection- Consignee" | Numbers | 7.00 | 1,240.68 | 8,684.76 |
| 57 | "Supply of PVC insulated multi strand, single corecopper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn. No. IRS: S-76/89 (Amnd-3) or latest. Each coil should be of100/200/500 meters length. Color of the wire which is required will be specified by the Engineer in charge. Inspection:Consignee subject to procurement from RDSO approved vendors " | Kilometre | 1.00 | 6,499.15 | 6,499.15 |
| 58 | "Supply of 1 x 10Sq.mm. (Green) multi strand copper power wire as per IS: 694:2010 or latest, 140 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in-charge Inspection: Consignee" | Metre | 500.00 | 100.85 | 50,425 |
| 59 | "Supply of Drill Bit 9/32' (7.14mm) IS:5099/83 and 5101/69 or latest Make: JK or Any branded company Inspection: Consignee" | Numbers | 100.00 | 43.22 | 4,322 |
| Schedule total | ₹12,42,595.91 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .