THE COMMISSIONER
TIRUCHENGODE MUNICIPALITY
WATER SUPPLY FUND 2023-24-Attending repair and renewals of 215HP HSC Pump Unit II, 215 HP Unit-II for 630 Amps MCCB MV Panel ,MV Panal 800 Amps ACB at Karumagoundampalayam, 5 HP Vaccum pumpset Unit-I at Avathipalayam BS and MV Panal 1000 Amps ACB Uni
2023_MAWS_403201_4
4948/2023/E1
Open Tender
Maintenance Works
Works
180 days
TIRUCHENGODE MUNICIPALITY
-
1 document required · 1 mandatory
₹0
₹4,100
Yes
18 Jan 2024
25 Dec 2023
5 Jan 2024
25 Dec 2023
5 Jan 2024
25 Dec 2023
Amount
215HP HSC Pump Unit II Karumagoundampalayam.
Dismantling and removing the top cover pump, removing the impeller shaft and other roating damaged and wornout meterials from the roating assembly etc complete.
Supply and fixing of New Bronze Shaft Sleeve after adjusted the old scrap meterial etc complete.
Supply and fixing of impeller shield ring after adjusted the old scrap meterial etc complete.
Supply and fixing of water Thrower after adjusted the old scrap meterial etc complete.
Supplay and fixing of SS 304 Shaft key after adjusting old scrap materials etc complete.
Supplay and fixing of impiller lock nut after adjusting old scrap materials etc complete.
Supplay ,delivery and fixing of pump brarings for DE side N 309 after adjusting old scrap materials etc complete.
Supplay ,delivery and fixing of pump brarings for DE side 6309/C3 after adjusting old scrap materials etc complete.
Charges for pr pump DE & NDE side bearing housing sleeve in CI Materials to connect the bearing seating area to rectify the loose condition etc complete.
Charges for fixing pump packing sheet top cover complete new bolt & nut after adjusting old scrap materials/
Charges for the bed alignment commissioning lead lfit, tools and zero- Zero accurancy and painting etc complete
Suppy, delivery and fixing of Fenner 120 Tyre coupling with 12mm Bolt nuts 16 Nos.( spare-1 no)
215 HP Unit-II for 630 Amps MCCB MV Panel at Karumagoundampalayam
Supply and delivery of 630 Amps MCCB with THERMO MAGNETIC RELEASE 3 pole (TWAD S R22-23 page-124)
Supply and delivery of Spreader Terminal 630 A- 3 pole
Rate for cable joints Including jointing materials and labour 400Sqmm X 3.5 core (TWAD SR 22-23 page-121)
Labour charges for Removing Damaged fo MCCB fixing New MCCB at MV Panel at site.
Supply and delivery of power capacitor for power factor improvement (TWAD SR 22-23 page-205)
Supply and delivery of Copper Flat 25 X 6 (TWAD SR 22-23 page-205)
5 HP Vaccum pumpset Unit-I at Avathipalayam BS.
Removing the pump from the base plate by looseinig nuts and bolts disconnection suction and delivery flanges.
Removing the pump top assembly and rotating parts removing worn-out bearings, impeller and fincling faults in them.
Supply and fixing of DE & NDE Bearings
Welding the damaged portion in pump shaft marching and reconditioning etc.,
Providing bearing sleeves at DE & NDE sides including lathe work.
Removing the worn-out impeller supply and fixing of new Gun metal Impeller including lathe works.
Assembling the impeller and bearings pumpset completely connecting suction and delivery pipe line flages pump aligning the exact position painting and testing etc.
MV Panal 800 Amps ACB at karumagoundampalayam BS.
Charges for Dismantling and removing of the 800 AMPS burnt and damaged ACB from LT Panel for using special tool arrangements and inspecting the ACB complete.
Supply , delivery and fixing of 415 volts , shunt relay with plunger rod arrangements (After adjusting the old Scrap Materials).
Supply ,delivery and fixing of 415volts UVR relay (under voltage Release) with plunger rod Arrangements (after adjusting the old scrap materials)
Supply and delivery of high grade carbon steel main control spring with suitable bolt, stud and nuts (After adjusting the old Scrap Materials).
Charges for removing broken springs down rods, roller with relevant bolt, studs and attending the faults and supply and fixing the down rod, roller with relevant studs, bolt and nuts, locknuts etc checking the operating system mechanically and electrically in the desk top arrangements with qualified personal's etc.
Charges for assembling the new spares shunt relay with necessary bolt and nuts operating liver screws moving fine copper contacts. OLR copper coils brass with necessary Allen screws bolt and nuts and fixing are chutes etc.
Charges for connecting all the internal control connection U/V coil, tripping coil (DLR ) ON/OFF indicator with necessary multi core insulated cable sockets ferrules with necessary multi core insulated cable sockets ferrules etc and checking the ACB internal operations using 415 volts power supply including testing commissioning of ACB etc., complete.
Charges for Removing the insulation failled lightning arrester from the 6 poies structure with clamp set and fixing of new testing 22 KV lighting arresters for 3 phase with bold and nut and providing earth connections etc., after deduct the old scrap materials
MV Panal 1000 Amps ACB Unit- II at Sandapettai BS.
Charges for Dismantling and removing of the 1000 AMPS burnt and damaged ACB from LT Panel for using special tool arrangements and inspecting the ACB complete.
Supply , delivery and fixing of 415 volts , shunt relay with plunger rod arrangements (After adjusting the old Scrap Materials).
Supply and delivery of high grade carbon steel main control spring with suitable bolt, stud and nuts (After adjusting the old Scrap Materials).
Charges for removing broken springs down rods, roller with relevant bolt, studs and attending the faults and supply and fixing the down rod, roller with relevant studs, bolt and nuts, locknuts etc checking the operating system mechanically and electrically in the desk top arrangements with qualified personal's etc.
Charges for assembling the new spares shunt relay with necessary bolt and nuts operating liver screws moving fine copper contacts. OLR copper coils brass with necessary Allen screws bolt and nuts and fixing are chutes etc.
Charges for connecting all the internal control connection U/V coil, tripping coil (DLR ) ON/OFF indicator with necessary multi core insulated cable sockets ferrules with necessary multi core insulated cable sockets ferrules etc and checking the ACB internal operations using 415 volts power supply including testing commissioning of ACB etc., complete.
S S INFRA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_479900.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .