Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-Finance 3082 6578 GURUJANG NANDA SAHI NEAR GURUJANG HIGH SCHOOL TALCHER ANGUL 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹26.4 L | L1 | Accepted-Finance L1 Bidder recommended as per financial evaluation committee |
| 2 | L2₹29.2 L+₹2.8 L (10.5%)Rejected-Finance PLOT NO 515 JAGANNATH BHAWAN PROFESSORPARA B K ROAD A D MARKET CUTTACK 753 012 ODISHA | CUTTACK | CUTTACK | ODISHA | 753012 | ₹29.2 L+₹2.8 L (10.5%) | L2 | Rejected-Finance L2 Bidder |
| 3 | L3₹29.3 L+₹2.9 L (10.9%)Rejected-Finance | ₹29.3 L+₹2.9 L (10.9%) | L3 | Rejected-Finance L3 Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Failure to provide necessary documents |
| 5 | Rejected-Technical | - | - | Rejected-Technical Failure to provide necessary documents |
| Sl No | Description | Qty | Unit | M/s. B.K. GIRI L2 | ORISSA TRADING HOUSE L3 | BHARAT ENGINEERIN L1 |
|---|---|---|---|---|---|---|
| 1.00HT, 33KV, CABLES: Supply, installation testing & commissioning of HT, 33KV grade XLPE insulated, inner sheath tapped, outer sheath PVC extruded, GI strip/armored, multi stranded/ Aluminum conductor power 33KV HT cable as per IS 7098 specifications, FRLS grade anti-rodent and anti-termite PVC (ST-2) outer sheathed cable, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid up, Inner sheath of PVC in ground at a depth of 900mm below ground level, sand bedding, laying of baked bricks on side and top, temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 500m and making good to the original finish etc. or hume pipes/ trenches. All as per the instructions of Engineer-in-charge-IOP. The tinned copper earth wires to be laid along with the cables should be painted with two coats of black bituminous compound for earth wire in ground & Jointing of the earth wire shall be solder joints with tinned copper cable sockets & GI nuts & bolts. Note: Scope includes all types of masonry work required making good to its original finish of holes through wall, slopes etc. after laying of the cable. Make of cables: Finolex/Polycab/CCI or approved equivalent of the same. | ||||||
| 1.01 | 01 no x 3core x 240 Sqmm Al. XLPE cable, 33KV HT, and 01 nos. of 06 SWG tinned copper earth wire. (From Old 33KV Switch Yard to Switch Yard near Over Head Water Tank) | 425 | Mtr. | 6,375 ₹27,09,375 | 6,700 ₹28,47,500 | 5,755 ₹24,45,875 Lowest |
| 2.00Supplying and making Outdoor Cable End Termination/ Straight Through Joint with Heat Shrinkable Jointing Kit complete with all accessories including lugs/ in-line connector for following size of XLPE insulated Aluminium conductor cable of 33KV grade as required. Note: 1. Insulation resistance of the cable is to be measured by a 5KV megger/ Insulation tester and to be recorded before and after the replacement of end joint/ Straight through Joint. 2. Arrangement of all instrument and equipment’s for this job is in the scope of Bidder. 3. The make of the 33KV, End Termination Kit/ Straight through Joint Kit should be of M/s Raychem Make or approved equivalent of the same. 4. Installation of end Termination Kit should be made by a Raychem certified cable jointer. 5. Five years of warranty is to be extended on the new joint. | ||||||
| 2.01 | Outdoor heat shrinkable cable end jointing kit with lugs for 3core x 240 Sqmm Al. XLPE, 33KV HT cable | 2 | Nos | 22,500 ₹45,000 Lowest | 25,000 ₹50,000 | 38,200 ₹76,400 |
| 2.02 | Outdoor heat shrinkable cable Straight Through jointing kit with lugs/ ferrules for 3core x 240 Sqmm Al. XLPE, 33KV HT cable
(This item will be executed only in case of requirement) | 1 | No. | 42,500 ₹42,500 | 10,000 ₹10,000 Lowest | 68,924 ₹68,924 |
| 3.00 | Suitable Support MS Channels for raising the cable for connection on the structure of 33KV Switch Yard at both 33KV Substation and the switch yard near Overhead water tank. The channels are to be provided on both side of cable to enclose the cable in between and same has to be fixed to the existing structure by suitable GI clamps and nut bolts (to be provided at a gap of 400mm on existing structure). Suitable MS strip extensions with holes and Nuts & Bolts to be provided on the channels to hold together both the channel around the cable tightly and same will be tightly secured with the existing structure by suitable GI clamps and Nuts & Bolts. The channels are to be painted with two coats of Red Oxide Primer and two coats of Aluminium Paint. Channel size (50x100x50x05(thickness) mm) and each set will have two channels each of length of 5mtr. Each.
Note:
The Scope of job includes the additional GI clamps with required Nuts and Bolts required for fixing the/ holding the cable with the existing 33KV structure. | 2 | Sets | 60,000 ₹1,20,000 | 10,000 ₹20,000 Lowest | 23,800 ₹47,600 |
Tender Value
₹34.8 L
EMD Value
₹1.7 L
Closing Date
4 Aug 2025, 6:00 pmClosed
REGISTRAR
Institute of Physics,PO-Sainik School,Bhubaneswar
Laying of HT, 33KV, 240Sqmm, XLPE Cable
2025_IOPB_868450_1
NIT/IOP/113/2025-26
Open Tender
Electrical Works
Works
60 days
Institute of Physics, PO-Sainik School, Bhubaneswar
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1.7 L
Yes
29 May 2026
11 Jul 2025
5 Aug 2025
11 Jul 2025
4 Aug 2025
11 Jul 2025
11 Jul 2025 - 31 Jul 2025
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.04 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .