Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.2 LQualified Make: EXIDE
Model: EP26-12 VOLT EXIDE MAKE 64 BLOCK D BANGUR AVENUE KOLKATA KOLKATA WEST BENGAL 700055 | 24 PARAGANAS NORTH | WEST BENGAL | 700055 | Make: EXIDE
Model: EP26-12 VOLT EXIDE MAKE | L1 | Qualified | |
| 2 | L2₹2.3 L+₹4,500 (2.00%)Qualified Make: AMARON QUANTA
Model: 12AL026 00 GODSAR PANDEY KALANA CHHANBEY MIRZAPUR UTTAR PRADESH 231303 | MIRZAPUR | UTTAR PRADESH | 231303 | Make: AMARON QUANTA
Model: 12AL026 | L2 | Qualified | |
| 3 | L4₹2.5 L+₹25,500 (11.4%)Qualified Make: Okaya
Model: OKAYA OB 26-12V 2 YEARS FLAT NO G1 SY NO 122 P LOTUS BLOCK FORTUNE ICON ROAD NO 10 BANJARA HILLS HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | Make: Okaya
Model: OKAYA OB 26-12V 2 YEARS | L4 | Qualified | |
| 4 | L5₹2.5 L+₹30,500 (13.6%)Qualified Make: ROCKET
Model: ROCKET & 12V/26AH 15 GF DSIDC SCHEME 3 PHASE II OKHLA INDUSTERIAL AREA NEW DELHI 110020 SOUTH DELHI DADRA AND NAGAR HAVELI INDIA | SOUTH EAST DELHI | DELHI | 110020 | Make: ROCKET
Model: ROCKET & 12V/26AH | L5 | Qualified | |
| 5 | L6₹2.6 L+₹34,700 (15.5%)Qualified Make: AMARON QUANTA
Model: AMARON QUANTA 1ST FLOOR P 27 PRINCEP STREET CHANDNI KOLKATA WEST BENGAL 700072 | KOLKATA | WEST BENGAL | 700072 | Make: AMARON QUANTA
Model: AMARON QUANTA | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Jul 2018, 10:00 amClosed
lead acid battery Experience with Gov. Required 2 Year (s) Lead Acid Battery ( 100 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 26 26 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 1470 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. - 1/3 No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab BANGALORE - Name of the Lab CPRI - Test Report No. 302EATDBT14S0044 - Test Report Date 11/09/2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications N/A - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jupudi Navya 500069
Directorate of SINT- CO
Advanced Systems Laboratory C/o: Research Centre Imarat (RCI) Dr. APJ Abdul Kalam Missile Complex Vigynana Kancha Post 100 15
336725
GEM/2018/B/47728
lead acid battery
15 days
Telangana; Ranga Reddy
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| lead acid battery Experience with Gov. Required 2 Year (s) Lead Acid Battery ( 100 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 26 26 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 1470 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. - 1/3 No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab BANGALORE - Name of the Lab CPRI - Test Report No. 302EATDBT14S0044 - Test Report Date 11/09/2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications N/A - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jupudi Navya 500069 | - | - | - |
| Directorate of SINT- CO | - | - | - |
| Advanced Systems Laboratory C/o: Research Centre Imarat (RCI) Dr. APJ Abdul Kalam Missile Complex Vigynana Kancha Post 100 15 | - | - | - |
Exempted
23 Jul 2018
16 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_336725.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .