Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.0 Cr
EMD Value
₹2.0 L
Closing Date
23 Feb 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Construction of 24x7 PHC Building at Tikarpada of Saintala Block under National Health Mission in the Bolangir district of Odisha (Scope of work in addition to above is uploaded separately along with this NIT)
NBCC/ODISHA/ZO/NHM/NIT/22-23/004
NBCC/ODISHA/ZO/NHM/NIT/22-23/004
Open Tender-Domestic
Civil Works General
Balangir, Odisha
₹11,800
₹2.0 L
23 Feb 2023
8 Feb 2023
23 Feb 2023
23 Feb 2023
9 Mar 2023
Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6 stone agregate
167 4 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, 0 0.00
curring, shuttering etc. complete all depth and height. 0 0
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm
size hard granite chips including watering, curing, conveyance of all materials to worksite,
payment of royalty, taxes etc all complete as per specification and direction of the
Engineer in charge 0.000
Supplying all materials, labour, T&P and providing Pidifin 2K including conveyance of all
materials to worksite, payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Factory made single leaf solid WPC (wood polymer ) composite door shutter of 25mm
thick compacted with wood grain finish structural foam paner of 29mm thickness and a
density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as
tower blits,aldrops, handles etc shall be provided. A structural adhesive compatible with
(EPS) foam shall be used for bending the core material ,The material and process for
173 7 manufacturing the door shutters shall confrom to RV-TIFAC composites design centres 0 0.00
standards and specification and the door shutters conforming to relevant I.S.
specification . The finish of door shutter will be plain colour white /lvory/beige/light
grey/mahogany/Teak wood or any other colour using high quality pigmments. Three
heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on
one side of shutter. 0 0
Factory made solid WPC door frame of size 95mmx55mm fabricated .The door frame
consist of four segments which are provided with plug-in-socket arrangement in-situ in
the mould. The segments are plugged in and are joined together by means of screw .
The WPC frame shall be provided with the material and process for manufacturing the
door frames shall conform to relavent I.S Specification. the finish of door frame will be
plain colour white /lvory/Beige/light grey/Golden brown/mahogany/Teak wood /sand
stone/Champagne/pastel blue of any other colour using high quality pigments complete in
all respect as per specification and direction of the engineer in charge. 0 0
177 B.ii EXTERNAL P.H. & SANITARY WORK. :- 0 0.00 0 0.00
Supplying all materials, labour, T & P and constructing Gully trap chamber of the following
inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size
h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap ,
178 1 Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) 0 0.00 0 0.00
finished with a floating coat of neat cement including fixing 100mm x100mm size gully
trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification
and direction of Engineer-in-charge.
179 0 250mmx250mm with RCC cover Each 8.00 1456.238 11,649.90
Supplying all materials, labour, T & P and constructing Inspection chamber of the
following inside size with CC (1:3:6) mix using 40mm size h.g. metal on bed, Ist class Fly
Ash brickwork in CM (1:6) , moulding and shaping the channel inside and benching with
CC (1:2:4) using 12mm size h.g. chips, 12mm thick cement plastering (1:3) finished with
punning to inside , cement flush pointing (1:3) to outside , R.C.C. cover slab in (1:2:4)
using 12mm size h.g. chips with RCC man hole cover , earth work in excavation in all
kinds of soil and refilling the cavity around the chamber including watering ,curing,
conveyance of all materials to worksite , payment of royality , taxes etc. all complete as
per aproved drawing , specification and direction of Engineer-in-charge.
181 0 Inside size 760mm x760mm x450mm Each 6.00 10296.68 61,780.08
Supplying all materials, labour, T&P and laying in trenches (to level or slope)
unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for
class-3(0.60mpa) including jointing with supply of approved solvent cement by non-heat
182 3 application method/as per manufacturer’s specification, providing and laying in trench 0 0.00 0 0.00
cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard
bedding surrounding or encasing including concrete for bedding and curing etc all
complete as per PH specification and direction of the Engineer-in-charge.
183 a) 110mm dia u-pvc pipe alround concrete mtr 60.00 1301.658 78,099.48
184 b) 160mm dia u-pvc pipe alround concrete mtr 60.00 2157.63 1,29,457.80
Supplying all materials, labour, T&P and constructing Man hole chamber of the following
size with cement concrete (1:3:6) using 40 mm size HG metal on bed , !st class Fly Ash
Brick work in CM (1:6) moulding and shaping the channel inside and benching with CC
(1:2:4) mix using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning
185 4 to inside, cement flush pointing (1:3) to outside ,RCC cover slab in (1:2:4) mix using 12 0 0.00 0 0.00
mm size H.G chips with RCC man hole cover , earth work in all kinds of soil and refilling
the cavity around the camber including watering, curing, conveyance of all materials to
worksite payment of royalty, taxes etc. all completed as per approved drawing,
specification and direction of Engineer-in-charge.
186 a) Inside size 900mmx900mmx900mm each 5.00 19311.29 96,556.45
187 b) addl depth of 0.30m upto 4.50m depth each 3.00 2051.076 6,153.23
Supplying all materials, labour, T&P and constructing soakway pit of the following size
with precast RCC rings joined loose, gravel backing in the rear of well steining, precast
RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron
lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well
excavation in all kinds of soil and refilling of cavity around the pit & painting the iron
works, watering, curing, conveyance of all materials to worksite, payment of royalty,
taxes etc all complete as per approved specification and direction of the Engineer-In-
189 a) RCC rings soakway pit 1.8m dia x 2.6m deep each 1.00 23328.364 23,328.36
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Construction of 1 No production wells including scientific source finding through
191 1 consolidated and unconsolidated rock with down the hammer drilling rig or combination 0 0.00 0 0.00
rig with PVC pipe and installation of submersible pump set with all acessories
Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below
ground level through consolidated and unconsolidated rock with down the hole hammer
drilling rig or combination rig as required to suit the site condition as per the direction of
the Engineer in charge including use of own rig with its accessories, tools and plant and
consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for
192 0 housing fitted with socket and with or without well screen as per the necessity for soft, 0 0.00 0 0.00
medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent
collapse of overburden is to be provided by the contractor including lowering and
withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden
portion including packing of gravel supplied by the contractor for 400mm dia bore only
193 0 Drilling of 200mm dia bore 0 0.00 0 0.00
196 4 Drilling of 150mm dia bore 0.00 0.00 0 0.00
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes
as per the necessity from ground level up to 45.00m depth and fitted and fixed up in
perfectly vertical position including cutting and threading of pipes and slotted pipes and
supplying and fixing all jointing materials, tools and plant etc all complete and keeping the
top of casing pipe threaded including plugging tube wells to prevent entry of foreign
199 6 Lowering of 200mm dia P.V.C casing pipes 0 0.00 0 0.00
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance
with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be
3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The
pipe having external thread at one end i.e female and or belled end. The female end
202 8 having internal thread is to be belled in order to accept the male end while jointing pipes 0.00 0.00 0 0.00
with a bore threading shall be provided with a greave at the roof of the male thread
accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe
shall be blue. The name of the manufacture along with batch No class of pipe shall be
stranded legibly of each pipe length.
Supplying all materials, labour, T&P and providing and providing sanitary sealing by
cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m
below ground level (as per drawing) to plug the bore hole excluding cost of cement all
complete as per direction of the Engineer in charge. Minimum one metre of casing pipe
to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding
cost of cement which will be supplied directly by the department)
Cleaning and developing the tube well with supply of compressor worked till clear and
205 10 adequate discharge is obtained from the tube well including supply and use of all 0 0.00 0 0.00
necessary equipment and labour as per direction of the Engineer in charge
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump
with squirrel cage induction type submersible type submersible electric motor to run on 3
phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89
207 11 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, 0 0.00 0 0.00
electrification, testing, commissioning, trial running, conveyance of all materials to
worksite, payment of taxes etc all complete as per specification and direction of the
Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)
2 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge
capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby)
209 12 DOL Control panel Each 2 4490.49 8,980.98
210 13 40mm dia steel short piece Each 2 238.36 476.72
212 15 50mm size CI bracket Pair 1 107.734 107.73
214 17 20mm dia rigid UPVC pipes Mtr 35 8.142 284.97
215 18 Steel rope with cover Mtr 35 31.506 1,102.71
216 19 Labour charges for lowering including transportation Each 2 2360 4,720.00
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor
HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following
217 20 nominal bore with clamps and jointing by Fusion welding method including testing, 0 0.00 0 0.00
making good the wall, ceiling and floor all complete as per specification and direction of
the Engineer in charge
218 0 32mm HDPE pipes (Finolex/Supreme make) mtr 85.00 117.764 10,009.94
219 B.ii SEPTIC TANK. (50 USER) 0 0.00 0 0.00
Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and
other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100
metre and including dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-Charge. Cum 15.75
Filling at all depth with available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 15 cm in depth : consolidating each
deposited layer by ramming and watering complete (lead upto 100m) as directed by the
Engineer-In-charge. Cum 10.5525
Supplying of filling sand in foundation and over areas including watering, ramming,
222 3 consolidating and dressing, labours, tools, taxes etc. all complete as per the specification 1.4 335.238 469.33
and direction of E.I.C. Cum
Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6 stone agregate
223 4 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, 5736.806 4,015.76
curring, shuttering etc. complete all depth and height. Cum 0.7
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size
hard broken granite chips including watering, curing, conveyance of all materials to
worksite, payment of royalty, taxes etc all complete as per specification and direction of
the Engineer in charge Cum 2.482
Providing, lifting, hoisting and laying Reinforced cement concrete of M-250 grade as per
approved designs and drawings having a minimum compressive strength (in work test)
250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite
stone chips and screened and washed sharp sand for mortar of approved quality from
approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be
mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering,
laying and compaction concrete by using vibrators, watering and curing for 28 days,
centering and shuttering then after dismantling and removing debris from the work site
and finishing the exposed surface smooth providing grooves or beads wherever
necessary including cost, conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the work etc. complete in all
Supplying, straightening, cutting, bending, placing in position and binding reinforcement
steel work in RCC/reinforced brick works as per drawing and specification including
229 7 preparation of respective bar bending schedule and binding (Binding wire to be used as 8.44 10463.886 88,328.23
per the IS code) etc. all complete as per direction of Engineer-In-Charge.Cold Twisted
bars, Thermo-Mechanically-treated bars. Qntl
230 8 Fly Ash bricks Masinary (1:6) (in F & P). Cum 1.20 5340.562 6,422.03
12mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar
231 9 of mix 1:4 (1 cement : 4 fine sand) including neat cement punning & necessary 42.288 174.876 7,395.16
scaffolding, curing etc. all complete at all floors and all heights. SQM
Providing 16mm. thick cement plaster in all floors at all height with cement mortar of mix
(1:6) with OPC 53 grade cement finished smooth to inside smooth surface of brick
masonry walls after racking out the joints including watering and curing, rounding of
corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of
all materials and cost of all labours, sundries, T&P and scaffolding required for the work
etc. complete in all respect as desired by the Engineer in charge. SQM
Supplying all materials, labour, T&P and providing , fitting & fixing 100mm x100mm x100
mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm
233 11 size h.g chips all complete including watering, curing, conveyance of all materials to 2 365.446 730.89
worksite, payment of royalty all complete as per specification and direction of the
Engineer in charge. Each
Supplying all materials ,labour, T&P and making MS STEP IRON IN 20MM diameter MS
234 12 steel bars & fixing into walls of man hole/septic tank duly embedded in cement concrete 5 208.034 1,040.17
(1:3:6) complete as per specification and direction of the Engineer in charge. Each
235 0 Sub-Total of Plumbing Works 0 0 0 28,17,566.96
236 0 Electrical Works 0 0 0 0.00
Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point
/wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper
conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in
type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with
237 1 face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core 0 0.00 0 0.00
multistrand copper conductor as earth wire including all accesories and connection as per
direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
(Make of modular box,cover,switch & socket-Legrand Myrios/schneider opale/Eq) With
10Years Warenty
Recessed wiring to secondary light point looped from primary light point with 1.5sqmm
FRLSH PVC insulated single core multistrand copper conductor of ISI marked with
20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core
239 2 multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose Nos. 30.00 639.56 19,186.80
with all accessories & connection as per direction of Engineer-in-charge. (Make of wire
Finolex /Polycab/ Anchor / Havels/Eq) Average Length: 3 mtr
Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core
multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit
with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with
1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running
earth including all accessories & connection as per direction of Engineer in charge. (Make
of wire Finolex /Polycab/ Anchor / Havels/Eq) Group B
Recessed wiring to Twin control light point with 1.5 sq.mm FRLSH PVC insulated single
core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit
with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked
241 4 mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm Nos. 2.00 2304.54 4,609.08
FRLSH PVC insulated single core multistrand copper conductor as earth wire including all
accesories and connection as per direction of Engineer-in-charge. (Make of wire Finolex
/Polycab/ Anchor / Havels/Eq) Group C
Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular
switch ISI marked mounted on G.I moular box with face plate & cover of suitable size
including all accesories and connection on same switch board as per direction of
Engineer-in-charge.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated
single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC
conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with
243 6 face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core Nos. 2.00 2059.1 4,118.20
multistrand copper conductor as earth wire including all accesories and connection on
separate board as per direction of Engineer-in-charge.(Make of wire Finolex /Polycab/
Anchor / Havels/Eq) Group C
Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in
type switch ISI marked mounted on single G.I moular box with face plate & cover of
suitable size including all accesories and connection on separate board as per direction
of Engineer-in-charge.
Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI
marked mounted on G.I moular box with face plate & cover of suitable size including all
accesories and connection as per direction of Engineer-in-charge. 25Nos for Stage
Light,3Nos For Aquaguard.
Recessed wiring for A.C/ Power socket outlet with industrial type socket outlet, plug
247 9 top and metal chained cover in sheet steel enclosure ,20A/32A SP MCB including all Nos. 8.00 1137.52 9,100.16
accesories and connection as per direction of Engineer-in-charge.
Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated
single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC
conduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC
insulated single core multistrand copper conductor for running earth including all
accessories & connection as per direction of Engineer in charge. (Make of wire Finolex
/Polycab/ Anchor / Havels/Eq) Group C
Recessed wiring for 3 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in
type switch ISI marked mounted on single G.I moular box with face plate & cover of
suitable size including all accesories and connection on separate board as per direction
of Engineer-in-charge.
Recessed wiring to submain in 4 x 10 sq.mm FRLSH PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-
252 13 metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FRLSH PVC Mtrs 45.00 929.84 41,842.80
insulated single core multistrand copper conductor as earth wire as equired. (Make of
wire Finolex /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-
253 14 metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FRLSH PVC Mtrs 170.00 377.6 64,192.00
insulated single core multistrand copper conductor as earth wire as equired. (Make of
wire Finolex /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-
255 15 metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC Mtrs 350.00 285.56 99,946.00
insulated single core multistrand copper conductor as earth wire as equired. (Make of
wire Finolex /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-
256 16 metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC Mtrs 450.00 248.98 1,12,041.00
insulated single core multistrand copper conductor as earth wire as equired. (Make of
wire Finolex /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core
multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-
257 17 metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC Mtrs 150.00 218.3 32,745.00
insulated single core multistrand copper conductor as earth wire as equired. (Make of
wire Finolex /Polycab/ Anchor / Havels/Eq) (For Switch Board Looping)
Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution,
415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate,
259 0 interconnections, phosphatized and powder painted including earthing etc. as required 0 0.00 0 0.00
wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be
colour indication for tripping On ,Off & Trip/There should be mid trip position for toggles
for electrical fault conditions.(With 5Years Warenty)
Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin
proof, sheet steel clad ready made, double door horizontal type powder coated wall
mounted 4 way TPN Distribution Boards For PDB suitable for 440 V, three phase, 4 wire
50 Hz AC Supply complete with bottom detachable plate for interconnections etc as
below.Incommer 1 No-63A FP MCB (10KA) Outgoings-10/20A SP MCB 10KA-
12Nos.(Make-L&T/ Schneider/Legrand/Eq)
Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin
proof, sheet steel clad ready made, double door horizontal type powder coated wall
mounted 12 way SPN Distribution Boards For LDB suitable for 440 V, three phase, 4
wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as
below.Incommer 1 No-40A DP MCB (10KA) Outgoings-10A SP MCB 10KA-
10Nos.(Make-L&T/ Schneider/Legrand/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable
of 1.1 KV grade of 3.5core 50 sq.mm direct in ground including excavation , sand
cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR
Kable/Rhino cable/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable
of 1.1 KV grade of 3.5core 35 sq.mm direct in ground including excavation , sand
cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR
Kable/Rhino cable/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable
264 21 of 1.1 KV grade of 4 core 16 sq.mm Aluminium on surface as required.(Make- Rmt 35.00 370.52 12,968.20
polycab/RR Kable/Rhino cable/Eq)
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
265 0 END TERMINATION 0 0.00 0 0.00
Supplying and making end termination with brass compression gland and aluminum lugs
266 0 for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV 0 0.00 0 0.00
Supply, installation,testing & commissioning of floor mounting front operated front access
extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55
protection with hinged and lockabale doors.CRCA sheets including
interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for
use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA
symmetrical for 1 sec at 415 V complete as per specifications, as required and as below
: All switchboards shall have provision for entry of cables from the bottom as required. All
live accessible parts shall be shrouded and all equipment shall be finger touch proof. The
bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar
supports shall be used with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter
and control fuse etc. complete.MAKE- Legrand / Schneider/ L&T/SIEMENS/Eq.
MAIN PANEL with 100A 4P MCCB 25KA -1 No as incomer,125A 4P C.O. SWITCH
272 25 1Nos,63A 4P MCB 10KA 4Nos.63A 4P C.O. SWITCH 1Nos, 40A DP MCB 10KA 3Nos, set 1.00 128000.5 1,28,000.50
with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB.
EXT Light DB with 63A 4P MCB (10KA) -1 No as incomer, 1Nos Timer Switch ,20A SP
MCB 10KA-12 Nos, 20A DP MCB 10KA 6Nos. as Outgoing with E.C Busbars .
PUMP Panel Board with 63A 4P MCB (10KA) as Incomer , Outgoings-32A 4P MAB
10KA-2Nos, 20 A DP MCB 10KA-3Nos, with E.C Busbars.
Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including
276 28 accessories and providing masonary with cover plate having loccking arrangement and Set 2.00 13212.46 26,424.92
watering pipe etc with charcoal and salt as required.
Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below
ground level as strip earth electrode including soldering etc. as required.
Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess
for connection etc as required.
Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required.
280 32 Lightning Protection System. 0 0.00 0 0.00
281 (a) Supply & fixing of lightning arrester ABB ESS Type. Nos 1.00 370971.94 3,70,971.94
282 (b) Earthing with 50mm dia 3mtr long cupper With 2nos compoung (25kg) as required . Set 2.00 17110 34,220.00
Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact
fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc.
284 0 directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm 0 0.00 0 0.00
FR PVC insulated single core multistrand copper conductor and earthing as
required.Make-Bajaj/philips/wipro/JAQUAR/Eq.With 5Years Warenty.
285 33 Ceiling mounted indoor type 24w batten type LED Luminaire Nos 76.00 644.28 48,965.28
286 34 Ceiling/ Wall mounted type 10w BULK HEAD Luminaire Nos 5.00 1465.56 7,327.80
287 35 Supply, Installation, testing and commissioning of 10W Mirror Light Nos 8.00 365.8 2,926.40
Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep USHA
288 36 ENERGIA, including wiring the down rods of standard length (upto 30 cm) with 1.5 Nos 50.00 2527.56 1,26,378.00
sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.
Supply, Installation, testing and commissioning of exhaust fan of 230 mm sweep
AEROCLEAN LD GBD 900 rpm in the existing opening, including making the hole to suit
the size of the above fan, making good the damage complete, connection, etc as
290 38 Supply & fixing of 15W LED Down Light (Surface/Recessed) Nos 25.00 1500.96 37,524.00
291 39 Supply & fixing of LED 36w 2'x2' Surface/Recessed Mounted Light Nos 10.00 3600.18 36,001.80
Supplying and fixing of clip in type modular Telephone socket ISI marked mounted on
294 40 G.I modular box with face plate & cover of suitable size ,including all accesories and Nos 4.00 450.76 1,803.04
connection as per direction of Engineer in Charge.
Supplying and fixing of clip in type modular T.V. antenna socket ISI marked on mounted
295 41 on G.I modular box with face plate & cover of suitable size , including all accesories and Nos 2.00 462.56 925.12
connection as per direction of Engineer in Charge.
Supplying and drawing 4 pair, 0.5 sq.mm FR PVC insulated coper conductor,
unarmoured telephone cable in existing surface / recessed PVC conduit as required.
Recessed wiring to television point with cable RG-6 grade, 0.7 mm solid copper
conductor PE insulated shielded with fine tined copper braid and protected with FR PVC
sheath in in existing surface / recessed PVC conduit as required as per direction of
Engineer in Charge.
Supplying and fixing of following sizes PVC conduit along with accessories in recessed
298 44 wiring including cutting the wall and making good the same in case of recessed conduit 0 0.00 0 0.00
Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deep on
surface / recess with suitable size of phenolic laminated sheet cover in front including
300 45 cutting the wall and making good the same in case of recessed conduit as required. Nos 4.00 212.4 849.60
( Tel junction Box)
301 46 Supplying & Commissioning of Telephone Hand Set. Nos 4.00 866.12 3,464.48
Supplying & installation of 10 pair KRONE make moudles with locking & key
302 47 arrangements fabricated with MS sheet & powder coated to be fixed on concealed set 1.00 1098.58 1,098.58
manner incl. good the damages.
303 0 SAFETY EQUIPMENTS 0 0.00 0 0.00
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm
thick Electrical tested with test certificate.
Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each
stand for Electrical fire protection as per standards of Electrical Inspectorate.
Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test
Supply and fixing of shock treatement charts duly laminated along with separate colour
single line diagram laminated, to be fixed in Electrical control panel room.
Supply and fixing of first aid box with medicines complete with medicine with three years
expiry date to be fixed in Electrical control panel room.
309 0 EXTERNAL ELECTRICAL/SUBSTATION WORKS 0 0 0 0.00
Supply of all Materials, Labour and Stringing of 11 KV Overhead Line with, 55 mm2
Insulated Aluminum Conductor, on 100 X 116 mm RS Joist 10 Mtrs. long complete with
required Insulators, Cross Arms, Stays Set complete as per site requirement and
Direction of Engineer-In-Charge.
312 B. 63 KVA 11 / 0.4 KV OUTDOOR SUBSTATION 0 0.00 0 0.00
Supply, Erection & Testing of 10.0 Mtrs. Long 116 mm X 100 mm Joist Pole with 400 X
400 X 6 mm Base Plate to be used as Substation of Double-Pole Structure support
including excavation of Pole Pit in all kinds of Soil, PCC Base Padding, Back Filling of the
Pit with 1:3:6 PCC, Painting with two coats of Red oxide Primer and two coats of
Aluminum Paint, Construction of Brick Masonry, Cooping, fixing of Danger Board etc.
complete as required.
Supply and Erection of Structure Materials on Existing Pole supports made out of
fabricated M.S. Channels, Angles etc. as per the approved Drawing including cost of
Clamp, Nut Bolts, painting with 2 coats of Red Oxide Primer and 2 coats of Aluminum
Paint complete as required for the proposed Four Pole Structure.
Installation, Testing and Commissioning of 63 KVA, 11 / 0.433 KV Copper Wound ONAN
DY11 Transformer.
Supply, Erection and Testing of 11 KV 400 Amp. Horizontal Gang Operated A.B. Switch
316 4 on Existing Double Pole Structure including cost of GI Pipe operating Handle of Set 1.00 8850 8,850.00
appropriate Length, Nut Bolts etc. complete as required.
Supply, Erection and Testing of 11 KV 400 Amp. Horizontal Gap Fuse on Existing Double
Pole Structure including cost of Nut Bolts etc. complete as required.
Supply, Erection and Testing of 12 KV Lightning Arrestor on Existing Double Pole
318 6 Structure including cost of mounting arrangements, Nut Bolts etc. complete as required. Set 3.00 1062 3,186.00
Supply and Jumpering of 55 mm2 Insulated Aluminum Conductor including cost of
Jumpering, Binding with Insulators etc. complete as required.
Supply of all Materials, Installation & Testing of 3 Mtrs. long 50 mm Diameter Class–B
perforated GI Pipe Earth Electrode confirming IS:3043 including cost of Salt, Charcoal,
320 8 Masonry Enclosure, C I Cover, Watering Funnel, Labour Charges for excavation of Pit in Nos. 4.00 4130 16,520.00
all kinds of Soil complete as required (For Body, Lightning Arrestor & DP).
Supply of Materials and Installation of Safe Earth Electrodes (Chemical Earthing)
321 9 including cost of Electrode, Earthing Compound, Excavation of Earthing Pit, Refilling, etc. Nos. 3.00 17700 53,100.00
as required (For Neutral).
Supply of Materials and Laying Underground / Floor / Wall including making End
Termination and testing of following sizes of G.I. Earthing Conductor Earthing of
Equipment's, Switch Boards and Panels as required complete as per Direction of
Engineer-In-Charge.
Supply of Materials and laying Underground / Floor / Wall including making End
Termination and Testing of following sizes of Copper Flat for Loop Earthing of
Equipment’s, Switch Boards & Panels as required complete as per Direction of Engineer-
328 C. PANEL BOARDS & DBS: 0 0.00 0 0.00
Supply, Installation and Testing of L.T. Outdoor / Indoor Floor mounted type Distribution
Boards made out of 2 mm thick CR Sheet Metal Cubicle, duly Acid treated for Derusting,
Premiered and painted with 2 coats of Enamel Paint of approved shade; Dust, Damp and
Vermin proved; having Hinged Door and Compartmental Arrangement for each
329 1 equipment and Busbar Chamber on the Top of the Panel running horizontally; having 0 0.00 0 0.00
provision for Cable/ Conduit Entry, Earthing Studs as per specification mentioned below
duly factory wired conforming to the relevant ISS and as per special conditions of
contract making good the damages caused complete as per the Direction of Engineer-In-
330 (a) Outdoor Sub Station Panel 0 0.00 0 0.00
331 0 Bus bars: 4 Nos. 200 Amp. Aluminum Busbar. Set 1.00 59000 59,000.00
Supply of all Materials, Installation & Testing of 3 Mtrs. Long 50 mm Diameter Class–B
Perforated GI Pipe Earth Electrode confirming IS:3043 including cost of Salt, Charcoal,
333 1 Masonry Enclosure, C I Cover, Watering Funnel, Labour Charges for Excavation of Pit in No 2.00 4130 8,260.00
all kinds of Soil complete as required (For Body Earthing of Panel Board & DB - 6 Nos. &
for Pump 2 Nos.).
Supply of Materials and Installation of Safe Earth Electrodes (Chemical Earthing)
334 2 including cost of Electrode, Earthing Compound, Excavation of Earthing Pit, Refilling, etc. No 2.00 17700 35,400.00
as required (For Lightning Protection System).
Supply of Materials and Laying Underground / Floor / Wall including making End
Termination and testing of following sizes of G.I. Earthing Conductor for Loop Earthing of
Equipment's, Switch Boards & Panels as required complete as per Direction of Engineer-
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supply of Materials and Laying Underground / Floor / Wall including making end
337 4 termination and testing of 8 SWG G.I. Wire for Loop Earthing of Equipment's, Switch Mtrs. 50.00 29.5 1,475.00
Boards & Panels as required complete as per Direction of Engineer-In-Charge.
338 E. SAFETY EQUIPMENT'S: 0 0.00 0 0.00
339 1 Supply and hanging of Shock Treatment Chart duly Laminated. Nos. 3.00 619.5 1,858.50
340 2 Supply & Laying of 8 mm Thick Rubber Mat, ISI mark of 1100 V Grade. Sqm 12.00 908.6 10,903.20
Supply and Installation of 3 Nos. Fire Buckets on a Mild Steel Stand complete as per
specification and requirement of Fire Safety Provisions.
Supply and Installation of 5 Kgs. Capacity CO2 type Fire Extinguisher complete as
343 5 Supply and Installation of 440 Volt Danger Boards. Nos. 4.00 141.6 566.40
344 6 Supply and fixing of 100 mm dia GI Pipe. Mtrs. 12.00 708 8,496.00
345 0 Sub-Total of Electrical Works 26,70,965.40
346 Grand Total 2,02,76,341.65
346 Grand Total 2,02,76,341.65
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
5 NIT.pdf
Tender Document
3a GCC PMC Contracting Works.pdf
Tender Document
3b SCC.pdf
Tender Document
8 Milestone.pdf
Tender Document
11 BOQ BOL 004 NHM.pdf
Tender Document
13 List of Approved Makes NHM Project Odisha.pdf
Tender Document
14 Scope of Work.pdf
Tender Document
Drawings Bolangir PHC at Tikarpada.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .