| 1 | L-1₹32.1 LAccepted-Finance FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L-1 | Accepted-Finance LOWEST TENDERER | |
| 2 | L-2₹32.9 L+₹73,121 (2.28%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L-2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L-3₹33.9 L+₹1.8 L (5.54%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L-3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L-4₹34.9 L+₹2.7 L (8.48%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L-4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L-5₹36.8 L+₹4.6 L (14.4%)Rejected-Finance | L-5 | Rejected-Finance GREATER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Maj Komal Parihar
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPECIAL REPAIRS TO BLDG NO P-71 AT INS SHIVAJI LONAVLA
2020_MES_379134_1
GE/LONAVLA/8949/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹95,000
Yes
14 Oct 2020
19 Sept 2020
12 Oct 2020
19 Sept 2020
10 Oct 2020
27 Sept 2020
20 Sept 2020 - 26 Sept 2020
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc.
M&L for rendering 10 mm thick cement plaster in CM 1:6 on brick work/concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified.
M&L for cement sand plaster in 2 coats 12mm and 8mm thick over the brick work in 1:4 cement sand mix admixes with integral waterproofing compound @ dosage of 200 MI per Bag of cement with a rough finish to receive finishes etc complete (make : Dr fixit pidiproof LW+equivalent product by STP/Fosroc)
M&L for preparation of new plastered surface of wall and applying two coat of oil bound diatemper over the alkali resistance priming paint primer over 3mm thick wall care putty complete all as specified and as directed.
M&L for complete removal of existing treatment of old painted wall surfaces and applying 3.00 mm thick white cement based wall care putty smooth finish.etc of approved make & shade on walls and other places complete all as specified and as directed.
M&L for complete removal of existing treatment of old painted ceiling surfaces and applying 3.00 mm thick white cement based wall care putty smooth finish.etc of approved make & shade on ceiling and other places complete all as specified and as directed.
M&L for applying one coats of priming with alkali resistant priming paint over the putty surface complete all as specified and as directed.
M&L for praparation of new or previously untreated surfaces and applying two coat of oil bound distemper over the primer surface of approved make & shade on walls, ceiling etc, complete all as specified and as directed.
Preparing new plastered external surface of wall and applying 2 Coats of Acrylic elastomeric exterior waterproof coating (Dr. Fixit Raincoat or of equivalent make mentioned in list of manufacturers herein after) with extra coat on rain lashed walls, dead walls, projections & Parapet wall top on primed surface with Efflorescence resistant penetrating primer (Dr. Fixit Primeseal or of equivalent make mentioned in list of manufacturers herein after) diluted with 50% water. Work shall be executed by engaging the approved applicator of the manufacturer and as approved by GE.
Dismantling of floor, hearth or wall tiling including cement mortar bedding.
Dismantling stone slabs and tiles of any descritpion or thickness in floors laid bedded in any mortar complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as directed.
M&L for rendering 10mm thick in CM 1:3 as in backing coat of as in skirting and glazed tiles in walls complete all as specified and directed.
M&L for Screed bed or bedding layer of mortar 15mm thick for laying floor finished in cm 1:4.
M&L for 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) in subbase for floor tiles complete all as specified and directed.
M&L for Matt finished (Salt and pepper series) Vitrified ceramic tiles of any shades 10mm thick (square/rectangular) polished, area of each tile n.exc 0.36 sqm, in floors, skirtings for passage / verandah etc set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specifed and as directed.
S&F Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement ,complete all as specifed and as directed.
S&F Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surfaces such as skirting dados and risers steps etc set and jointed in neat cement slurry and pointed in white cement. Incl cutting the tiles to the required size whereven required incl mitring the corners etc, complete all as specified and directed.
Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars all as directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing with neat cement slurry with 3.00 kg cement per sqm
M&L for Cement concrete in foundations, bases of columns/posts, filling and mass-concrete Type B2 1:2:4 (40 mm graded aggre-gate)
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
S & F MS steel work in tubular/roof trusses (framed),purlines,rafters etc, complete including nessary cutting, welding,fabrication and eraction Machine hydraulic bending etc complete using ERW pipes or indution butt welded tubes,confirming to IS 1161-1998 (Gde E-250) quality-A, complete all as specified and directed.
S&F Mild steel in rolled section as in main and cross beam , hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding door ,fixed with angle cleat or other connecting plates ,grade Fe-410-W (Gde-E-250) quality -A and complete all as specifed and directed. .
M&L for Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc complete all as specified and directed.
S&F wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed.
S&F for Pre- Painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in ridge,valley, gutter etc fixed with self tapping screws as specified.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F 160 mm dia PVC rain water gutter including all fittings such as bends elbows connectors, reducers, brackets, end caps etc fixed to roof with necessary brackets
S&F PVC (SWR) pipes single socketed 110 mm dia, in any length with rubber ring joints as downtake rainwater carrying pipes with all pipe fittings such as ends, elbows, unions, brackets, sockets, plugs, hose clips etc fixed to walls
S&F 16 to 20mm diameter of neck mild steel screws bolts any length (machine made) with hexagonal or square heads at one end and screwed the other ,or screwed both ends each screwed and to be fitted with washers and one hexagonal or square nut,n,exc.5cm etc complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description having width or girth exceeding 10 cm and applying two coats of synthetic enamel paint complete all as specified and as directed.
Dismantling of MS works of any description such as ,ladders, grating etc, including necessary straightening of bends complete all as specified and directed.
M&L for cutting holes into or through reinforced cement concrete work/brick work/stone masonry including reinforcement cut through if reqd, super facial area not exc 150 sqcm each and making good in CM (1:3) or cement concrete (1:2:4), type B-1 as required complete all as specified and as directed. Note:- To be operated with prior approval of Accepting Officer.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20 mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all fittings such as Tee, bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 16 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all fittings such as Tee, bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
Tubes, ‘medium grade’ galvanised, 25 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors
S&F in repairs 500 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position including 20mm dia ball brass valves ,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed all as specified in ssr part-I complete all as specified and directed.
S&F in repairs Bib taps, fancy type, chromium plated with crutch sc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and as directed.
S&F in repairs Pillar taps, fancy type, chromium plated, screwed down, high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15 mm bore complete all as specified and as directed.
S&F in repairs 15mm stop valves, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch , screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs Angle cock, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair PVC connections, 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames), exc 1.50 sqm but not exc 4.0 sqm each complete as directed
S&F for Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per spcification & drawing etc, complete all as specified and as directed.
S&F for 30 mm Factory made Moulded door shutter - Wood free consisting of frame made out of M.S. tube of 19 gauge thickness and size of 25 mm X 25 mm for stiles, top and bottom rails M.S. frame shall have a coat of steel primer. The inner panel shall consist of 25 mm thick High density EPSconforming to IS 4671-1984 bondedwith 2 mm termite proof, water proof and fire resistant molded PVC sheet with 2,4,6 raised panel designs in different plain and / or prelam colours after routing the Moulded design on one side & 2 mm plain and / or prelam PVC sheet on other side of the EPS. The edge of the panel is to be sealed with lipping of 10mm wide PVC sheet baton (made by sticking 2 nos , PVC sheets of 5 mmt thickness using PVC solvent cement ) and stile sides 25 mm (5mm x 5)thick and 30mm wide PVC sheet fitted along M.S tube for lock provision & for lock height 5 mm thick PVC sheet of 150 mm x 100 mm fixed with upper & lower face of inner side of EPS panel and manufacturer's specification & drawing etc, complete all as specified and directed.
Supply and fix aluminium alloy anodised Aldrop sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolt of extruded section of size 300 mm fixed at any position all as specified and directed.
S&F in stainless steel butt hinges, 100mm, medium weight complete all as specified and directed
S&F in extruded aluminium alloy handles, fabricated type of size 150mm in any position complete all as specified and directed.
S&F in aluminium, anodised, barrel tower bolts of extruded section of size 200mm complete all as specified and directed.
M&L for PCC 1:3:6 Mix Type C2 (using 40mm graded stone aggregates), 75mm thick as in plinth protection, complete all as specified and as directed.
M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade 'A' for thickness of slab 75mm complete all as specified and as directed.
M&L for reinforced concrete pipes class NP-2 ,150 mm dia laid and jointed coplete with collars and including demolition and breaking up Existing SGSW/RCC pipes concrete bed including packing under and haunching jointed in cement mortar and taking out of trenches if required etc, complete all as specifed and directed.
M&L concrete bed to 150 mm dia pipes of cement mortar 1;3;6 type C-2 including packing under and haunching against the side of pipes after they are laid and tested complete all as specifed and directed.
S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165.
Taking down steel/aluminium windows complete with all fittings n. exc 1.5 Sqm each, all as specified and as directed.
Taking down steel/aluminium windows/ventilator complete with all fittings exc 1.5 but n exc 4 Sqm each, all as specified and as directed.
S&F Powder coated aluminium three track, three shutter (equal width) type window miniumum 15 micron anodised with frame made of aluminium sections of size 91.80 x 31.75 x 1.2mm and shutters made out of aluminium sections 39.4 x17.7 x 1.2mm without sash bars including necessary jointing cleats, glazing clips, rubber packing, anodised snap beadings, screws aluminium fittings lockings arragngements etc including 4.00mm thick sheet glass for glazed shutters and stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm for wire gauge shutter all as specified and as directed, before.
S&F powder coated aluminium ventilator partly fixed and partly louvered type without sash bar section as per minimum 15 micross anodised including necessary jointing, clip, rubber packing, anodised snap beading crews and 4mm thick pin headed glass etc complete.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for issue under Schedule of credit and making good disturbed surfaces of walls, floors, etc.
Taking down MCB DBs / SFUs
M & L for point wiring with 1.5 sq mm single core PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover / PVC Switch Board mounted on wall for mounting the switches , socket outlets , fan regulators etc all as s specified and directed for One light/Fan point controlled by one switch.
All as per item No.70 above but for one socket 3 pin outlet 5 amp on independent board.
All as per item No.70 above but for one 3 pin socket outlet 5 amp on the same board board with other switches.
All as per item No.70 above but for one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item No 70 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm.
S&F in repairs switch piano flush type single pole one way 5 amp.
S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified.
S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type. .
S&F in repairs switch socket combination 2 in 1,5 amp flush type.
S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type.
S&F in repairs switch bell push, flush type 5 Amp.
S&F in repairs bell, electronic type AC, 230 Volts single pole.
S&F in repairs fan regulator flush type complete all as directed by EIC at site
M&L for replacement of lamp holder, insulated body with back plate batten/angle type for batten fitting complete all as specified & directed.
Supply and fix new adore LED lamp 15 Watt confirming to Cat No LHLDERUEMD8X015 of Havell's or euivalent in Philips / Bajaj
S&F in repairs LED Tube light 18 Watt LED complete set prewireed upto terminal block complete with all accessories and connecting up with twin core / .0076 flexible copper wire with and including LED tube light fixed on two nos PVC round / square mounting blocks complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No for Batten-BLRB DB 118, and for LED Tube Rod Cat No BLRB 18W CW LED of Bajaj or equivalent of Havell's/Philips / Wipro
Supply & fix in repairs 45 W pressure die cast aluminium housing LED Building light secondary optics IP 66 protection including connection with two core twisted copper flexible cable, Make - Bajaj, Cat No - BRTFG 45W LED WW or equivalent make of Havells /Philips/CG
Supply and fix in replacement of LED Tube light of 10 watt (2") with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:Bajaj CAT Part No BCLSB 10 NW (2ft) or equivalent to CG/Philips/Wipro complete all as specified and directed .
S&F in replacement vertical type DB , (VTPN) suitable for and including MCCB 4 pole, 125 amps, 16KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 4 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed ,
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB SPN 35-63 amps, 240 Volts, Complete all as specified and directed.
S&F in repairs MCB SP 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
Supply and fix in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto 06 -32 Apms
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
M&L for making hole in wall of size 300 mm dia to 450 mm dia for mounting of exhaust fan, making good the disturbed surfaces to match the existing complete all as directed by Engineer-in-Charge at site
Dismantling the existing energy Meters, MCCB / MCB Distribution boards by disconnecting the eletric supply connection and refixing at new or same location after carrying out repairs / replacement , reconnecting complete all as directed by EIC at site.
Supply & fix fans ceiling complete with accessories 230 V,1200 mm sweep. BEE 5 star rated including taking down old u/s ceiling fan and deposited to MES store complete all as specified and as directed.
Supply & fix exhaust fans metal body complete with and accessories 230 V,300 mm sweep including taking down old u/s exhaust fan and deposited to MES store complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and as directed.
Supply & fix Air Circulator/ Wall Mounted fans 230 volts single phase oscillating 300 mm sweep suitable for wall mountingcomplete all as specified and as directed.
M&L for taking down ceiling fan and Opening of body cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for following complete all as directed by Engineer-in-Charge.
Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of pipes and getting out in Soft / loose Soil
Cutting bituminus road as per direction of Engr in Charge for laying of UG cable and match the existing road to the existing system.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm.
Removing excavated material n. exc. 50 M away and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and as directed.
M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified. Note :- Cushioning will be measured and paid after punning down.
Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
Supply and lay in trenches / along the wall / floor pipes GI light grade of size 100 mm dia with and including all fittings and accessories including taking down old U/S pipe complete all as specified and and directed for cable protection
SAI SAMARTH ENTERPRISES
M/s S.D Construction Co
VIJAYA ENTERPRISES
RK AND SONS CREATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .