Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹22.9 L+₹1.1 L (5.22%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 3 | L3₹23.2 L+₹1.4 L (6.65%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 4 | L4₹24.2 L+₹2.5 L (11.6%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L4 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 5 | L5₹26.7 L+₹5.0 L (22.9%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER. |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
6 Mar 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIRS OF ROOF AND WATER PROOFING TREATMENT AND OTHER CONNECTED WKS IN OTM MD ACCN OF AUNDH MIL STN AND RANGE HILLS AREA REPAIRS TO COMPOUND WALL FENCING ETC IN RANGE HILLS AREA AND AUNDH MIL STN UNDER GE MH AND RH KHADKI
2024_MES_641326_1
8540/E8
Open Tender
Civil Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹84,000
13 Apr 2024
8 Feb 2024
8 Mar 2024
8 Feb 2024
6 Mar 2024
23 Feb 2024
8 Feb 2024 - 28 Feb 2024
Amount
Taking down cement or cement lime plaster of any description all as specified and directed .
M& L for rendering of external surface 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finishsed including uprooting/cutting of vegetation growth (maximum height upto three stories) using WPC @ 3% by weight of cement all as specified and directed. Note: WPC will be measured and paid seperately
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels, etc of average thickness 20mm in CM (1:3) with water proofing compound, finished even and smooth without using extra cement all as specified and directed. Note :- Rates shall deemed to be inclusive of Cost of water proofing compound.
Supply only intergral water proofing compound.
M & L applying two coats of cement base paint to newly plastered surface of wall including preparation.
M & L for complete removal of existing finishes, upto any height, by scraping down of old decorative surface of walls with steel wire brushes of smoke spots, moulds, efflorescent salts and cutting/uprooting vegetations growth, including filling of spots with POP and applying of two coat of cement base paint over a coat of primer and necessary prepation of surface all as specified and directed.
M&L for rendering of internal surfaces 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement ) all as specified and directed
M&L for of preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer finished even and smooth, all as speciified and directed
M & L for complete removal of existing finishes by scraping down old decorative surface of walls with steel wire brushes of smoke spots, moulds, efflorescent salts and applying two coats of oil bound distemper over a coat of alkali resistant primer all as specified and directed.
M&L for complete removal of existing finishes by scraping down old decorative surface of walls with steel wire brushes of smoke spots, moulds, efflorescent salts including filling of spots with POP and applying two coats of white wash on old surfaces of walls all as specified and directed.
M&L for rendering 10 mm thick on concrete surface in CM 1 :4 as in ceiling etc. all as specified and directed.
M&L for preparation of new plastered surface and for applying three coats of white wash on ceiling all as specified and directed.
M&L preparation of old surfaces applying of one coat of white wash on ceiling all as specified and directed.
Taking down shutters of any description exceeding 1.00 Sqm and n.exc 2.00 Sqm each and refixing the same after easing and adjusing in same opening all as specified and directed.
Demolition of brickwork or stone work/boulder masonary built in cement mortar or cement lime mortar all as specified
M&L for precast cement concrete, type C-1, 1:3:6 (20mm graded aggregate ) masonary with solid blocks, exc 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store.
S & F 15 mm bore tubes, medium grade, galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors.
Fixing only tubes of 15 mm bore, any grade, to walls and ceiling or laying in floors.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store.
S & F 20 mm bore tubes, medium grade, galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors.
S & F in repair PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and directed. (Make : CERA, Shakti or equivalent )
S & F in repairs Vitreous China Squatting pan Orissa pattern long pan, size 580 mmX440mm white with `P' or `S' trap, front or back inlet and foot rests any pattern including connection to trap and to flushing pipe, anti-syphonage pipe etc, including trap set in and including concrete complete including making good to floor all as specified and directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white fixing bolts (excluding flushing cistern) but including flush pipe, connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe complete, all as specified and directed.
S&F 100mm dia PVC (SWR) pipe in floor or in trenches complete all as specified and directed including taking down existing pipe.
S&F in repairs Cast iron floor trap 100 mm bore with grating including jointing to waste pipe and fixed with PCC 1:2:4 , all as specified and directed.
S&F 75mm dia PVC (SWR) pipe in floor or in trenches complete all as specified and directed including taking down existing pipe.
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregates for filleting, benching, slightly rounding or chamfering on edges, filling undulations / depressions in roof surface, providing concrete platform for tanks wherever required as directed.
Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and disposal of the same to distance exceeding 50m but not exceeding 100m as and where directed and M & L for 15 mm thick screeding / rendering in cement mortar 1:4 on concrete roof surface, using Water Proofing Compound @ 3% by weight of cement, surface finished even and smooth without using extra cement all as directed. Note: Water Proofing Compound shall be measured and paid separately.
M & L for cleaning the plastered /concrete surface with wire brush and applying water proofing treatment as under:- (a) Apply one coat of water based bituminious primer @ 0.20 Kg per Sqm. (b) Laying APP polimerised modified membrane weighing not less than 3.5Kg / sqm by torch application method. (thickness of membrane shall not be less than 3 mm). (c) The overlap for APP membrane shall be 75 mm on longitudinal direction and100 mm on transverse direction. (d) Finally applying a coat of solar reflective bituminious aluminium paint @0.15 Kg/Sqm over the membrane.
Disconnecting existing tanks exc 250 & not exc 500, setting asides (or lowering if required) for repairs, cleaning, waterproofing etc and hoisting if required reconnecting and re-fixing in position.
Disconnecting existing tanks exc 500 & not exc 1000, setting asides (or lowering if required) for repairs, cleaning, waterproofing etc and hoisting if required reconnecting and re-fixing in position.
Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and M&L for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
Making hole and M&L for fixing thr metallic packer for hydrophobic PU foam and Sealer as per manufacturers specification. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tille with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, or equivalent , curing , cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
M&L for water proofing treatment of External walls, chhajjas DFT: 110 microns by applying two coats of elestromeric coating Raincoat, material covering capabity 3 Sqm per litre in 2 Coats without dilution & 1 coat of efflorescent resistant primer 10sqm/litre/coat after cleaning the surface throughly and sealing all cracks with acrylic sealing compound as per the manufacturers specifications and directions of Engr-in-Charge Make :- Raincoat shall be of PlDlLlTE or equivalent. The product shall have following properties: Elongation > 100% as per ASTM D 412, Tensile strength : 2.5 Mpa as per ASTM D 412, Water Resistance conforming to SS 500, Crack bridging ability conforming to Class A4 as per EN 1062 Part 7, Positive hydrostatic pressure > 7 bar as per DIN 1048, Anti-carbonation property complying EN 1062 Part 6, RCPT conforming to ASTM C 1202.
Demolition of brickwork or stone work/boulder masonary built in cement mortar or cement lime mortar all as specified
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement morter 1:4 complete all as specified and as directed.
M&L for preparation of new undecorated surface of wall and applying two coats of cement base paint over a coat of primer.
M&L preparation old decorated surfaces of walls and applying one coat of cement base paint all as specified.
Dismantling fencing, wire mesh any type complete all as specified and directed by Engr in Charge
Dismantling of RCC post or struts carefully of any section embedded in concrete incl taking out embedded portion and making good disturbed ground incl taking down/out worn out unserviceable old barbed wire, chain link fencing complete.
Excavation in post hole each n.exc 0.50 Cum getting out returning filling in and ramming earth around in layers n.exc 25cm watering and removed surplus soil to a distance n.exc 50m in soft/loose soil.
S&F Mild steel for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0
M&L for cement concrete in foundation PCC 1:3:6 type C2 using 40mm graded stone agg for fencing post etc.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
S&F in repairs galvanised 2 strand barbed wire 2.24mm dia of wire and 2mm dia of barbed at 75mm spacing and straining and fixing to any type of strandre nails straining bolts, including securing or tying at crossing with and provn of galvanised MS wire staples or steel pins etc as specified.
All as per item No. 22 here in before but restraining resecuring old fence including making good staples etc only all old wire fit for reuse as directed.
S&F in repair framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe 290 Gde-E-165
Dismantling structural steel work including doors, gates but excluding framed truss etc.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
M&L for 6 mm thick asbestos cement corrugated or semi corrugated sheets in roof fixed with 'L' type or J type or cranked hook bolts.
M&L Asbestos cement two piece adjustable plain wing ridge 6mm thick fixed with L-type or J-type hook to roof all as directed by Engr-in-charge
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old Roof sheet CGI/ PGI Sheet as specified and directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old Roof sheet CGI/ PGI Sheet complete all as specified and directed.
M&L for preparation of untreated new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint ( 1st grade quality ) over a coat of red oxide primer complete all as specified and as directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level)
M&L for cement concrete type D-2, 1:4:8 (40mm graded aggregate) 75 mm thick sub base or similar items all as specified and directed.
M&L fo Sand filling under floors or in foundation including watering and consolidation. (Thickness of cushion should not be less than 25mm).
M&L for 80mm thick coloured rubburised, glossy finish colour machine pressed interlocking pattern paver block any shape and size conforming to IS 15658-2006 of M-40 Grade incl all as specified and directed by Engineer-in Charge.
M&L for PCC 1:3:6 type C-1 , 75 mm thick as in plinth protection, Path, floor construction joint after every 2 mtr interval and from wall will be filled by mastic of bitumin/Compound grade 'A' all as specified and directed.
M& for Forming Contraction (Dummy) joints 75 mm deep x 10mm wide, filled with sealing compound complete all as specified and directed by EIC.
Taking down PVC (SWR) pipes 75 mm dia single sockets and S&F in any length rubber ring joints, laid in trenches or in floor all as specified and directed.
M&L for Cement concrete type B2 (1:2:4) 40 mm graded aggregate as in surface channels and drains complete all as specified and directed.
Extra for fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc.
Demolition of cement concrete (re inforced) in roof floors, beams, staircase, landings, chajjas, pillars etc and similar suspended works and removing materials from site of work complete all as directed.
Separating scraping and cleaning of reinforcement (Demolition of concrete measure separately)
M&L for precast cement concrete type B-1 1:2:4 (20mm graded agg) set in CM 1:6 as in cover slabs for manholes etc.
S&F TMT bars 6 to 8mm dia bar, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L for RCC B-1 1:2:4 (Nominal Mix), (20mm graded agg) in columns, pillars, piers, posts and struts all as specified.
M&L for RCC type B-1 1:2:4 (Nominal Mix), (20mm graded agg) as in Beams, cantilevers, bressummers, lintels over 1.5m span.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions all as specified.
Formwork to sides of and soffits of floor or roof beams, lintels cantilevers all as specified.
S&F of Mild TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410-W (Gde.E-250).
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
Demolition of Stone slabs and tiles of any description or thickness laided bedded and pointed in cement mortar in floors, aprons etc.
M&L Coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick plastering in cm 1:4 all as specified.
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete fixed over and including backing coat of 10mm thickin CM 1:4 all as specified
Demolition of cement concrete (un reinforced) any description in any position not otherwise described complete as specified.
M&L for providing precast cement concrete louvres and jallies, Type C0 1:3:6 (12.5mm graded aggregate) 25mm thick (measured solid) set in CM 1:4, including all mouldings but including pre cast frame complete all as specified and directed by Engr-in-Charge.
Demolition of stone slabs and tiles of any description or thickness laided bedded and pointed in cement mortar in floors, aprons etc.
M&L machine cut Kota stone slab 20-22mm thick in flooring, terrace flooring but one piece as in treads of staircase etc over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, over 15mm thick screed bed or bedding in CM 1:6 for laying floor finishes, including 50mm average thick 1:2:4 PCC levelling course complete all as specified and directed.
All as per item No 85 here-in-before but on vertical surface as skirting over and including 10mm thick rendering in CM 1:3 to receive Kota stone / slab etc complete all as specified and directed.
MAHESH DADAJI BACHHAV
S P DEVELOPERS
JP ENTERPRISES
M/S JAYCONSTRUCTION CO
M/S J J ENTERPRISES
Ridhi Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .