Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 197 4 KANTADANGA ROAD FINGAPARA N24PGS PIN 743129 | FINGAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L1 | Accepted-AOC AOC issued | |
| 2 | L2₹3.8 L+₹11,711.16 (3.16%)Rejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L2 | Rejected-Finance That the Bid is not L1 | |
| 3 | L3₹4.1 L+₹39,786 (10.7%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance That the Bid is not L1 | |
| 4 | L4₹4.3 L+₹59,286 (16.0%)Rejected-Finance 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L4 | Rejected-Finance That the Bid is not L1 | |
| 5 | L5₹4.5 L+₹78,526 (21.2%)Rejected-Finance 14 SURI LANE KOLKATA 14 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L5 | Rejected-Finance That the Bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹8,555
Closing Date
5 Feb 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Medical College and Hospital, Kolkata - Emergent repair works to the damaged rooms, corridors of inside portion and corrugated roof of outside portion for Main Boys Hostel during the year 2024-25 - Electrical Installation work.
2025_WBPWD_798892_1
WBPWD/AE/KMCESD/NIQ-131/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,555
15 Oct 2025
10 Jan 2025
7 Feb 2025
16 Jan 2025
5 Feb 2025
16 Jan 2025
Amount
A. Distribution wiring:--- Dismantling the existing E.I. work by Co's own tools & tackles and remove unnecessary,scrap items away from site by maintening normalcy as far as possible and deposit necessary materials to section office as per direction of EIC .
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] vide pg no E-15 item no. 5
avg run 10 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Havells/Glostar/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick as per GS.(on board) vide pg no E-15 item no. 4
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. (P/No., E-3. I/No. 6 (a) & 7(a)
19 mm dia 3 mm thick polythene pipe without earth continuity wire
25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: R.R Kable / Havells/Glostar/KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. vide pg no E-9 item no. 1 (b),(s),(y)
3 X 1.5 sqmm
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (from TPN to existing SPN DBs)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. vide pg no F-5 item no. 9
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories including drawing existing good insulated wires as required and mending good damages to building works 20 mm dia Pg E-16 item 7(a)
B. BDB, PDB, VTPN etc:--- Supplying and fixing double door Horizontal 6 way,TPN MCB Distribution board with IP-42/43 protection, on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand /Siemens/LK) as to GS. Vide page no D-11 item no 14
Supplying and fixing 240/415 V MCB on din rail of existing DBs and necessary connection.(Make-Legrand /Siemens/LK) Vide page no D-5 item no 6
i. 415 V ,63 A FP MCB for PBDB
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection .(Make-Legrand /Siemens/LK) Vide page no D-6 item no 7
ii. 6A - 32A SP MCB for PBDB & LBDB
C: Supply of Light fittings:- S/D 4feet single commercial LED type fluroscent light fittings (make--Philips TMC 502 1xT-LED 22W/ Wipro WIO921208P/ equivalent Lighting Technology) complete with all accessories with LED tube lamp corresponding to(Make- Philips 1200mm 20W865 T8 IND I /Wipro LL13-181-65SESL1-G1/equivalent Lighting Technology
D. Fixing of Light Fittings :--- Fixing only single/twin fluorescent light fittings suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp (125mmx125mm) x 6mm thick as per G S Vide page no C-2, Item no 17
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length as per G S Vide page no C2 Item no 16
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener / MS U Type or Double L Type MS clamp 6mm thick. Vide page no C2 Item no 14(b)
E. Plug & Sockets:--- S & F 240 V, 6 A plug socket 2 nos with separate 6 A piano key type switch 2 nos (Make-Anchor penta/ Havell's Reo) on sheet metal switch board embedded in wall incl. S & F 175 x 100 x 65 mm MS (16) SWG switch board and bakelite /perspex top cover of 3 mm thick by brass screws after making housing for switch by cutting bakelite /perspex cover and making necessary connection as required .(NS)
F: Fixing of fans :--- Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. page no C-3, Item no 21a
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. page no C-3, Item no 22
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting Vide page no D 14 Item no 29
S & F socket type Electronic fan regulator(230V,100W, step type ) (Make-Anchor penta/ Havell's Reo)
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
MAA TARA ENTERPRISE (BID ID -6051434)
ALPHA ELECTRICALS (BID ID -6070020)
A.K.ENTERPRISE (BID ID -6083484)
T.D.K. ENTERPRISE (BID ID -6088868)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .