Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.0 L+₹50,255 (1.27%)Rejected-Finance R2 612 GOPAL NAGAR BLOCK A DHANSA ROAD NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹41.8 L+₹2.3 L (5.88%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹45.2 L+₹5.7 L (14.5%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹45.9 L+₹6.4 L (16.2%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Mahesh Enterprises L6 | V r traders L4 | M/S Anand Enterprises L3 | J.P. Enterprises L5 | Commercial Traders L1 | Poorvi Enterprises L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying, jointing and testing as in repair cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core including all necessary acessories for fixing arrengement on wall / ceiling with saddles complete all as specified and directed by engineer in charge (Note : Cost of saddles etc. of suatable size are deemed to be included in unit quoted rate.) | 418 | RM | 455 ₹1,90,190 | 239 ₹99,902 | 200 ₹83,600 Lowest | 350 ₹1,46,300 | 243 ₹1,01,574 | 289 ₹1,20,802 |
| 2.00 | Design, supply, install, testing and commissioning in replacement of factory made LT Panel Outdoor type cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 1200 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves.
The panel shall be provided with separate compartments for each switch gear, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:
Incoming :-
(a) ACB 800 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Manual drawout type ( MDO ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cables complete- 1 set
(b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 Nos
(c) LED type Phase indicator lamps (R, Y, B) - 1 Set
Outgoings:-
(a) MCCB 500 Amps 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos
(b) MCCB 400Amp,4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos
(c) MCCB 200 Amp,4 pole rupturing capacity 25 KA at 415 volt, Ics = 100% Icu - 03 Nos
(d) Control MCB 6 Amps SP-03 Nos
Note for serial BOQ item No 2 to 5 and 25: (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT/ PT and electrical connection complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel .
The panel manufacturer should have following Govt. Approved Certificates:
1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54.
2. IS/IEC : 61439 (Part-1 & Part-II) 2011 and all necessary certification as per relevant IS/IEC codes | 1 | Each Job | 6,10,000 ₹6,10,000 | 5,89,999 ₹5,89,999 | 5,45,000 ₹5,45,000 | 5,47,500 ₹5,47,500 | 5,07,400 ₹5,07,400 | 5,00,900 ₹5,00,900 Lowest |
| 3.00 | Design, supply, install, testing and commissioning in replacement of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 800 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. (For AFCAO and EDP wing Panel)
The panel shall be provided with separate compartments for each switch, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:
Incoming:-
(a) MCCB 500 Amps 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos
(b) On Load Change Over Switch 500 Amps 4 Pole 415 Volts Open Execution panel mounted with operating handle - 1 Nos
(c) LED type Phase indicator lamps (R, Y, B) - 1 Set
Outgoings:-
(a) MCCB 400 Amps 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos
(b) MCCB 250 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 02 Nos
(c) Control MCB 6 Amps SP-03 Nos ( for Metering ) | 1 | Each Job | 4,20,000 ₹4,20,000 | 3,99,999 ₹3,99,999 | 4,10,000 ₹4,10,000 | 3,85,200 ₹3,85,200 | 3,68,160 ₹3,68,160 | 3,33,900 ₹3,33,900 Lowest |
| 4.00 | Design, supply, install, testing and commissioning in replacement of factory made LT Panel indoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of Front doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-42. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 600 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. (For AFCAO, OPW Bldg Panel)
The panel shall be provided with separate compartments for each switchgear, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, Front side openable with Cable alley on Both side of panel of suitable size not less than 250 mm with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:
Incoming :-
(a) MCCB 400Amp, 4 pole rupturing capacity 36 KA at 415 volt Icu=Ics = 100% - 01 Nos
(b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 No
(c) LED type Phase indicator lamps (R, Y, B) - 1 Set
Outgoings:-
(a) MCCB 250 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 01 Nos
(b) MCCB 200 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 01 Nos
(c) MCCB 125 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 02 Nos
(d) Control MCB 6 Amps SP-03 Nos | 1 | Each Job | 3,10,000 ₹3,10,000 | 2,99,999 ₹2,99,999 | 3,05,000 ₹3,05,000 | 2,88,000 ₹2,88,000 | 2,68,450 ₹2,68,450 | 1,79,000 ₹1,79,000 Lowest |
| 5.00 | Design, supply, install, testing and commissioning in replacement of factory made LT Panel indoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of Front doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-42. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 600 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves.
The panel shall be provided with separate compartments for each switchgear, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, Front side openable with Cable alley on Both side of panel of suitable size not less than 250 mm with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:
Incoming :-
(a) MCCB 400Amp, 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos
(b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 No
(c) LED type Phase indicator lamps (R, Y, B) - 1 Set
Outgoings:-
(a) MCCB 250 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 03 Nos.
(b) Control MCB 6 Amps SP-03 Nos | 1 | Each Job | 3,00,000 ₹3,00,000 | 2,79,999 ₹2,79,999 | 3,05,000 ₹3,05,000 | 2,75,000 ₹2,75,000 | 2,56,000 ₹2,56,000 | 1,51,900 ₹1,51,900 Lowest |
| 6.00 | Taking out old unserviceable Change over switch and supply and fix new (ON-Load) Changeover switch 4 pole of capacity 630 Amps, conforms to IS/IEC:60947-3) Phase Barriers & Handle with door interlock kit is integral part of the Changeover including necessary arrangements to fix the change over to connect incoming cable and out going cables including cable end boxes made out 2 mm thick CRCA sheet duly powder coated complete all as specified and directed.
Make- Havells Cat Part No. IHCNFE0630 or equivalent of L&T/ Schneider/ Seimens | 1 | Each Job | 55,000 ₹55,000 | 51,999 ₹51,999 | 54,000 ₹54,000 | 55,000 ₹55,000 | 39,210 ₹39,210 Lowest | 47,900 ₹47,900 |
| 7.00 | M&L as in repair for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron strip 25×4mm as earthing lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 3 of SSR Part I (2009) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified and directed. Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. | 8 | Each | 7,800 ₹62,400 | 5,499 ₹43,992 | 3,500 ₹28,000 Lowest | 6,000 ₹48,000 | 4,000 ₹32,000 | 6,090 ₹48,720 |
| 8.00 | M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc with galvanised iron strip 32 x 6mm complete all as specified and directed by Engineer-in-Charge. | 34 | RM | 110 ₹3,740 Lowest | 249 ₹8,466 | 300 ₹10,200 | 180 ₹6,120 | 156 ₹5,304 | 199 ₹6,766 |
| 9.00 | Excavation in trenches in any type of soil n.exe 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipeline /cable etc n.exe 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-charge. NOTE : while excavation , if tiles removed than Contractor shall refix the same tiles as per existing . The unit quoted rates including removing of tiles. | 60 | Cum | 230 ₹13,800 | 299 ₹17,940 | 120 ₹7,200 | 180 ₹10,800 | 85 ₹5,100 Lowest | 190 ₹11,400 |
| 10.00 | Returning filling in including spreading levelling watering and well ramming hard / dense soil in layers not.exc 25 cm each layers complete all as specified and as directed by Engineer-in-charge | 42 | Cum | 30 ₹1,260 | 49 ₹2,058 | 40 ₹1,680 | 50 ₹2,100 | 15 ₹630 Lowest | 19 ₹798 |
Tender Value
₹44.5 L
EMD Value
₹88,960
Closing Date
11 Jul 2025, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2025_MES_713510_1
GE/SP/TOKEN-63/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹88,960
Yes
2 Sept 2025
11 Jun 2025
14 Jul 2025
11 Jun 2025
11 Jul 2025
28 Jun 2025
Amount
Supply, laying, jointing and testing as in repair cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core including all necessary acessories for fixing arrengement on wall / ceiling with saddles complete all as specified and directed by engineer in charge (Note : Cost of saddles etc. of suatable size are deemed to be included in unit quoted rate.)
Design, supply, install, testing and commissioning in replacement of factory made LT Panel Outdoor type cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 1200 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch gear, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: Incoming :- (a) ACB 800 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Manual drawout type ( MDO ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cables complete- 1 set (b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 Nos (c) LED type Phase indicator lamps (R, Y, B) - 1 Set Outgoings:- (a) MCCB 500 Amps 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos (b) MCCB 400Amp,4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos (c) MCCB 200 Amp,4 pole rupturing capacity 25 KA at 415 volt, Ics = 100% Icu - 03 Nos (d) Control MCB 6 Amps SP-03 Nos Note for serial BOQ item No 2 to 5 and 25: (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT/ PT and electrical connection complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel . The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54. 2. IS/IEC : 61439 (Part-1 & Part-II) 2011 and all necessary certification as per relevant IS/IEC codes
Design, supply, install, testing and commissioning in replacement of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 800 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. (For AFCAO and EDP wing Panel) The panel shall be provided with separate compartments for each switch, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: Incoming:- (a) MCCB 500 Amps 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos (b) On Load Change Over Switch 500 Amps 4 Pole 415 Volts Open Execution panel mounted with operating handle - 1 Nos (c) LED type Phase indicator lamps (R, Y, B) - 1 Set Outgoings:- (a) MCCB 400 Amps 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos (b) MCCB 250 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 02 Nos (c) Control MCB 6 Amps SP-03 Nos ( for Metering )
Design, supply, install, testing and commissioning in replacement of factory made LT Panel indoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of Front doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-42. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 600 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. (For AFCAO, OPW Bldg Panel) The panel shall be provided with separate compartments for each switchgear, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, Front side openable with Cable alley on Both side of panel of suitable size not less than 250 mm with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: Incoming :- (a) MCCB 400Amp, 4 pole rupturing capacity 36 KA at 415 volt Icu=Ics = 100% - 01 Nos (b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 Set Outgoings:- (a) MCCB 250 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 01 Nos (b) MCCB 200 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 01 Nos (c) MCCB 125 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 02 Nos (d) Control MCB 6 Amps SP-03 Nos
Design, supply, install, testing and commissioning in replacement of factory made LT Panel indoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of Front doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-42. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 600 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switchgear, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, Front side openable with Cable alley on Both side of panel of suitable size not less than 250 mm with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: Incoming :- (a) MCCB 400Amp, 4 pole rupturing capacity 36 KA at 415 volt, Ics = 100% Icu - 01 Nos (b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 Set Outgoings:- (a) MCCB 250 Amp,4 pole rupturing capacity 25KA at 415 volt, Ics = 100% Icu - 03 Nos. (b) Control MCB 6 Amps SP-03 Nos
Taking out old unserviceable Change over switch and supply and fix new (ON-Load) Changeover switch 4 pole of capacity 630 Amps, conforms to IS/IEC:60947-3) Phase Barriers & Handle with door interlock kit is integral part of the Changeover including necessary arrangements to fix the change over to connect incoming cable and out going cables including cable end boxes made out 2 mm thick CRCA sheet duly powder coated complete all as specified and directed. Make- Havells Cat Part No. IHCNFE0630 or equivalent of L&T/ Schneider/ Seimens
M&L as in repair for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron strip 25×4mm as earthing lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 3 of SSR Part I (2009) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified and directed. Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner.
M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc with galvanised iron strip 32 x 6mm complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in any type of soil n.exe 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipeline /cable etc n.exe 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-charge. NOTE : while excavation , if tiles removed than Contractor shall refix the same tiles as per existing . The unit quoted rates including removing of tiles.
Returning filling in including spreading levelling watering and well ramming hard / dense soil in layers not.exc 25 cm each layers complete all as specified and as directed by Engineer-in-charge
Removal of excavated material & surplus soil to a distance n.exc 50 mtr and depositing where directed at a level not exe 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-charge
Supplying, spreading and compacting approved river sand in trenches for cable cushioning at bottom and top of cable complete all as specified and as directed by Engineer-in-charge
Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm laid in in trenches as protection to cable all as specified and directed by Engineer-in-charge
Supply and fixing of GI tubing galvanised iron tubing medium grade 50mm dia with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plug sand unions etc) complete with screwed socket joints laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of GI tubing galvanised iron tubing medium grade 40mm dia with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plug sand unions etc) complete with screwed socket joints laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and as directed by Engineer-in-charge.
M& L for Cutting existing GI tubing/ CI pipe line of dia 80/100/150mm for alterations or additions including screwing existing tubing for alteration or addition to pipe line suitable for bore of pipe 40 to 50mm with and including new fittings and fixtures complete all as specified and as directed by Engineer-in-charge.
M&L for Making good damaged surfaces of road to match the adjoining existing surfaces with using of paste premix bituminous 25mm thick polymer based material over WBM 75mm thick including rolling etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe 50mm dia complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe 40mm dia complete all as specified and as directed by Engineer-in-charge.
Supply and fixing non return valve of size 40mm dia complete with rubber flange, MS nuts & bolts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement of unserviceable PVC PTMT float valve 40 mm dia complete with PVC ball and connecting rod complete all as specified and directed
Supply and fix of Motor Guard( weather protection cover) made out of 18 gauge GI Sheet suitable for 7.5 HP centrifugal mono block pump set with lifting handle and provision of suction /dicharge pipeline Holes complete all as specified and directed
Supply and fix of PVC water tank cylendrical shape 3 layer of capacity 5000 LTRS fixing on PCC stage with proper connection of GI fittings including GI nipple 40 to 65 mm for outlet and union socket, tank connection,Tank cover etc complete all as specified and directed by Engr-in-Charge.
Supply & fix of monoblock centrifigual pump 7.5 HP capacity, 3 phase, 415Volts, 50 Hz AC, Head range 28-45 Mtr, Discharge 10.3-5.6 LPS, suction and delivery vale size 65/50 minimum, Power 7.4 KW, IP55 including fitting in given location with GI reducer 65x40 and 50x40 (Each 01 Nos) and connected socket, union fittings and electrical connections with control wire complete all as specified and directed by Engineer -in- Charge.
Supply and laying of PVC flat submersible copper cable LT 1100 volts grade of size 6 sqmm 3 core complete all as specifed and directed by Engr-in -Charge
Supply laying & jointing of PVC insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core laid in trenches / poles / on walls etc using clamps complete all as specifed and directed by Engr-in -Charge .
M&L for PCC (1:2:4) type B-0 (using 12.50 mm graded stone aggregate) as in sunken portion and making adequate slope toward spout pipe complete all as specified and as directed.
M&L for brick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in cm 1:4 complete all as specified and directed.
M&L for rendering 15 mm thick on concrete/ brick surface in CM (1:4) for making good surface complete all as specified and as directed by Engineer-in-charge.
M&L for road cutting 60 cm in depth and 45cm in width complete all as specified and directed. Note : All T&P required for cutting shall be provided by the contractor
Taking down ceiling fan forfixing/ installation of anti suicide rod and refixing the same ceiling fan including electric connection with suitable size copper cable etc complete all as specified and directed.
Supply and fixing of anti suicide fan(12") white MS pipe zinc plated,19mm OD 1.8+/- 0.5 mm thick, spring set grade 3 carbon steel material zinc plated,MSME tested for performance test and opening at impact load of 22kgf+ and spring " hidden in the pipe will expand to about 1 mtr or more , complete as specified and directed by Engineer in charge.
Poorvi Enterprises (BID ID -3346598)
M/S Anand Enterprises (BID ID -3346427)
V r traders (BID ID -3345499)
J.P. Enterprises (BID ID -3347084)
Mahesh Enterprises (BID ID -3345413)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .