Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹9.5 LAccepted-AOC | L-01 | Accepted-AOC Being lowest bidder | |
| 2 | L-02₹9.8 L+₹9,039.70 (0.93%)Rejected-Finance | L-02 | Rejected-Finance Not Being Lowest | |
| 3 | L-03₹9.9 L+₹15,100.74 (1.55%)Rejected-Finance | L-03 | Rejected-Finance Not Being Lowest | |
| 4 | L-04₹9.9 L+₹17,056.38 (1.75%)Rejected-Finance | L-04 | Rejected-Finance Not Being Lowest | |
| 5 | L-05₹10.0 L+₹23,883.86 (2.46%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L-05 | Rejected-Finance Not Being Lowest |
Tender Value
Refer Docs
EMD Value
₹18,600
Closing Date
5 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Darjeeling
AGE (I) Darjeeling POST - Jalapahar Dist - Darjeeling (WB)
REPAIR MAINT OF EXTERNAL WATER SUPPLY AND ALLIED WORKS UNDER AGE I DARJEELING
2020_MES_384752_1
8772/E8
Open Tender
Civil Works
Item Rate
182 days
Darjeeling
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Darjeeling
₹18,600
Yes
26 Dec 2020
8 Oct 2020
7 Nov 2020
8 Oct 2020
5 Nov 2020
23 Oct 2020
8 Oct 2020 - 14 Oct 2020
60 days
Amount
Excavation in Trenches, not exc. 1.50 Metre wide and not exc 1.50 Metre in depth for any type of foundation/cable trench and getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
M&L for cutting existing road/hard standing not exc 45x45cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finished suraface of depth not less than 10 cm from top using PCC 1:3:6, type C-2 (using 40mm graded aggregate); including removal of surplus soil complete all as specified and as directed.
Taking down / out old unserviceable GI tubing upto 20mm bore (dia) including all fittings and fixture from floor/wall or trenches including cleaning and stacking for refixing / reuse and removal unusable materals from site of work complete all as directed.
All as per ser item No 05 above but 25 mm bore of pipe complete all as specified and as directed.
All as per ser item No 05 here-in-before but 50 mm bore of pipe complete all as specified and as directed.
All as per ser item No 05 here-in-before but 80 mm bore of pipe complete all as specified and as directed.
S&F 20mm bore (dia) GI tubing 'medium grade' galvanised with all fittings laid in trenches, complete all as specified and as directed.
All as per ser item No 09 above but 25 mm bore of pipe complete all as specified and as directed.
All as per ser item No 09 above but 50 mm bore of pipe complete all as specified and as directed.
All as per ser item No 09 here-in-before but 80 mm bore of pipe complete all as specified and as directed.
S&F 20mm bore (dia) GI tubing 'medium grade' galvanised with all fittings fixed to wall, ceiling or laid in floor, complete all as specified and as directed.
All as per ser item No 13 above but 25 mm bore of pipe complete all as specified and as directed.
All as per ser item No 13 above but 50 mm bore of pipe complete all as specified and as directed.
All as per ser item No 13 here-in-before but 80 mm bore of pipe complete all as specified and as directed.
Taking up/down Old unserviceable GI flanges from the existing GI Pipe of size 80/50 mm dia all as specified and as directed.
S&F GI Flange of size 50mm bore,threaded type, ISI marked, with and including necessary nut-bolt, washer, gasket, etc., complete all as specified and as directed.
S&F GI Flange of size80mm bore,threaded type, ISI marked, with and including necessary nut-bolt, washer, gasket, etc., complete all as specified and as directed.
S&F of 20 mm bore (dia), gun metal gate valves with iron wheel head,screwed both ends for iron pipe, ISI Marked, as per IS: 778 and including taking out old unserviceable gate valves complete all as specified and as directed.
All as per ser item No 20 above but 25 mm bore of pipe complete all as specified and as directed.
All as per ser item No 20 above but 50 mm bore of pipe complete all as specified and as directed.
Supply & Fixing , jointing and testing of cast iron sluice Valve ISI mark (PN-1.6) of size 80 mm bore confirming to IS 14846-2000, flanged ends drilled having stainless steel / brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable sluice valves, complete all as specified and as directed.
Supply & fixing Cast Iron Air Release Valves (ARV) with Double air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia including taking out old unserviceable CI ARV all as specified and as directed.
All as per ser item No 24 above but 80 mm bore (dia) ARV siutable for Cast Iron Water supply mains of size 80 mm dia complete all as specified and as directed.
M&L Cutting existing GI water tubing of size 25 or 32 mm bore for alternations or addition including screwing/threading and jointing with suitable size GI socket complete all as specified and as directed by the Engineer-in-Charge.
M&L Cutting existing GI water tubing of size 40 or 50 mm bore for alternations or addition including screwing/threading and jointing with suitable size GI socket complete all as specified and as directed by the Engineer-in-Charge.
M&L Cutting existing GI water tubing of size 80 or 100 mm bore for alternations or addition including screwing/threading and jointing with suitable size GI socket complete all as specified and as directed by the Engineer-in-Charge.
Taking out/down and refixing of sluice valve in repairs incl repacking of gland stuffing box of size 80 mm in bore complete all as specified and as directed .
M&L for cleaning the surfaces of Steel overhead water reservoir of any capacity by following methods.- (a) Draining out reserved water by opening drain out valve/ dewatering system. (b) Removing all scale, dirt, mud inside the tank by sand blasting, if sand blasting is not possible, abrading with coarse emery paper is recommended and scrubbing the wall of tank. (c) Cleaning inside surfaces of the tank with Rust converter to remove rust from steel surfaces. (d) Drying out the surfaces by using drier . Note: (i) The quoted unit rate is included for removal of mud, grits & deposits etc properly from site of work.
M&L for application of Coat ZP by thr following methods- (i) Stiring the hardener and Resin individually with drill mixer of proper size. (ii) Add the entire content of the hardener into resin container and stir the two components throughly using a low speed mixer for 2-3 minutes until a uniform colour of mixer is obtained. (iii) Now apply a coat of Coat ZP (Internally and Externally) on the steel surfaces of the water tank of any capacity, Complete all as specified and as directed.
M&L for Rearm Tar coating after through mixing of base and hardener, the mixed material is applied by means of brush on steel or concrete surfaces. Since the pot-life is very short, application must be done very quickly. The second coat is applied when the first coat is tack free (Inside walls of tank) for tank of any capacity, complete all as specified and as directed.
M&L for leakage proofing coating, consists of two coats of Aqua Arm coat by means of taking a clean container of volume appx. 2.0ltr, stiring the base and hardener thoroughly in their individual packs to achieve uniform consistency. Pour the base and hardener into clean container, mix base and hardener upto a smooth paste like material, after proper mixing of the base and hardener add 500ml of water into the properly mixed paste. Mix the total mass upto a brushable consistancy. Apply the first coat of mixed quantity of Aqua Arm tank coat by brush allow it for 6 to 8 hrs. Allow it to cure completely for 24hrs before applying second coat of Aqua tank coat. The treatment of Aqua Arm tank coat can also be kept open, as the product processes the non toxic property . In such situtation allow it to cure for minimum 3-4 days prior to storage of the water for tank of any capacity, complete all as specified and as directed. Note: (i) On completion Guarantee certificate for 10 (Ten) Years for Leak Proofing to be submitted by the contractor/ Authorized applicator to the Engg-in-Charge.
M&L for construction of Brick Masonry Valve Pit, of size 900mm X 900mm X 900mm (Internal dimension), one Brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally upto full depth and externally upto 150mm below GL, providing 3.15mm thick MS black Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Synthetic enamel Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit, complete all as specified and as directed.
Taking out old unserviceable/corroded out valve pit MS cover of valve pit size 90cm x 90cm (LxB) and replace same with new valve pit cover made of 3.15mm thick MS black sheet welded to 40 x 6mm equal angle at sides and diagonals including 40 x 6mm equal angle for making resting base frame, both resting frame and cover should be hinged at two points along one side, including necessary locking arrangement all as directed by Engr-in-charge.
S&F in-repair LED Aviation Light with fitting of 09Watt, including making connection with 2-Core flexible copper wire of 0.50Sqmm size, complete all as specified and as directed. Make- CROMPTON GREAVES, Cat Part No.- LEDWTCH-230V GLN-703 or Equivalent of Make BAJAJ/HAVELLS/PHILIPS.
M&L for Sub-main Wiring with 2-Runs of Single Core 2.50 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 2.50 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board including taking down the existing unserviceable sub-main wiring with accessories, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
S&F in-repair Switch Piano, Flush type, single pole, 1-Way, 15/16 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
Supply and installation in-repair of Water Level indicator, FRP scale conventional type complete with float, guide wire, bracket & pully, counterweight, indicator pin, etc. for 5000 Gallon Water Tank, complete all as specified and as directed. Make- RMCO or equivalent
Demolition of Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
M&L Cement Concrete 1:4:8, type D-2 (40mm graded aggregate) in Foundations, Filling and Mass Concrete, staging of MS/PVC storage tanks, repairs to pathways etc. including use and waste of Formwork as required/ordered at Site(s), complete all as specified and as directed.
M&L for Complete removal of existing Surface Treatment of Walls and preparing the surfaces even and smooth including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying Two Coats of Weather Coat Paint (Exterior Grade) over a coat of Cement primer, complete all as specified and as directed.
M&L for Complete removal of existing Surface Treatment on old steel surfaces and preparing the surfaces even and smooth including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying Two Coats of Synthetic Enamel Paint (1st quality) over a coat of Zinc chrome primer, complete all as specified and as directed.
Supply only Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas and Stronger than bleaching powder and solidum Hypochlorite) Packing in 45 Kgs in plastic Drums complete all as specified and directed.Make Rayalseema,Brand Pure chlor
M/S TSHERING BHUTIA
GEETA CONSTRUCTION
RAI CONSTRUCTION
Damdoo Bhutia
Darjeeling Enterprises
Janata Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .