Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.7 L+₹3.2 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹26.6 L+₹7.0 L (35.9%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹26.9 L+₹7.3 L (37.4%)Rejected-Finance KOTWALI STREET MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MP | 474006 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹28.9 L+₹9.4 L (47.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹32.4 L
EMD Value
₹64,840
Closing Date
12 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8125/GWL/E8 PROVN OF CERTAIN REVENUE AND MINOR WORKS UNDER GE GWALIOR
2024_MES_683973_1
8125/GWL/E8
Open Tender
Civil Works
Works
180 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹64,840
Yes
21 Jan 2025
14 Nov 2024
14 Dec 2024
14 Nov 2024
12 Dec 2024
29 Nov 2024
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense of soil complete all as specified and directed.
M&L for surface dressing n.exc 15 cm deep in soft/loose soil complete all as specified and directed.
M&L for PCC (1:4:8) Type D2 using 40mm graded stone aggregate as in foundation filling mass concrete, complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping, complete all as specified and directed.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces, applied in two layers i.e. 1st layer of 10 mm thick rendering in cement mortar (1:6) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4) and top layer mixed with water proofing compound as per manufacturer's instruction & finished even and smooth without using extra cement including taking down existing cement plaster of any description and in any position and racking out joints, hacking for key, scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid seperately under appropriate item of BOQ as "supply only")
Supply only integral water proofing compound ISI marked complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 150mm bore of pipe complete all as specified and directed.
M&L for DWCPE Pipe (SN8) 180 (OD)/163 (ID) mm dia Pipes including testing alongwith necessary jointing material tees/union/socket etc complete all as specified and directed.
M&L Sand filling under floor or in foundations including watering and consolidation complete all as specified and as directed.
M&L for providing cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) in surfaces channels drains and benching including use and waste of form work and finishing fair and smooth using extra cement (forming fair finished channel shall be measured and paid for separately) complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 0.25 cm thick each layer complete all as specified and directed.
Removing excavated material (soil), not exceeding 50m and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in cover slabs for man holes and set in CM 1:4 including use and waste of necessary form work complete all as specified and directed. Note Renforcement and form work shall be measured paid separately)
Cutting holes in brick/ stone wall, depth of embedment portion of hold fast exc half brick wall but not exc one brick wall, built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as required complete all as specified and directed.
M&L Hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc wind ties for roof including securing bolts posts and struts in fencing post including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or rivetting, etc, and similar work conforming to Fe 290 Gde E 165 with and including applying two coats of synthetic enamel paint over a coat of primer alround before fixing in position complete all as specified and directed.
M&L for rubble random rubble uncoursed, well bounded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
M&L of flush pointing to RR masonary walling brought upto course in CM (1:4) complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L PCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in surface channels and drains etc complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed.
All as per Item No 22 above but each additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and directed.
M&L for Reinforced cement concrete (design mix) M-25 (using 20 mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better rough finished surfaces of concrete complete all as specified and directed.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as copings, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick work or conrete surfaces/stone masonary and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered sufaces of walls & applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick each layer complete all as specified and directed.
M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and untersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surfaces for applying two coats of Synthetic enamel (ordinary tint) over a coats of red oxide zinc chrome complete all as specified and directed.
Supply and fix Duct Type desert cooler electric driven (single phase), having nominal air flow capacity of 6000 Cum per hour of size 40''x40''x66'' with Steel body and 24'' heavy fan motar, 800 MSP pump, Float valve, flexible pipe & cooler stand that above all accessories are including in Quated rate complete all as specified and directed.
M&L for Duct of cooler of size 0.6m x 0.3m (l x b) in rectangular shape for uniformly distribute the cool air in all rooms and run from the air cooling unit to room of Medical ward in MH and cool every room or department by using Air grills all accessories are including in Quated rate complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 including fittings of size 50 mm in trenches complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 including fittings of size 15 mm in trenches complete all as specified and directed.
S&F in renewal of CPVC PIPE Ball Valve cofiorming to IS 14846/2000, ISI Mark MS Spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts fixed at any location of size 15 mm dia complete all as specified and directed.
S&F in renewal of CPVC PIPE Ball Valve cofiorming to IS 14846/2000, ISI Mark MS Spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts fixed at any location of size 50 mm dia complete all as specified and directed.
Rotational moulded polyethylene 1000 Ltr water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
M&L point wiring in conduit with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 2.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia with all fitting and fixing accessories and 2.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes factory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches sockets etc complete all as specified and directed.
S&F switch piano, flush button single pole one way 15 Amp complete all as specified and directed.
S&F socket out let multipurpose flush type, 2 in 1 6 Pin 5/15 amps complete all as specified and directed.
M&L sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 volts grade, 2.5 Sqmm size with multi stranded copper conductor (ISI marked with valid CML No), drawn in and including surface mounted non metallic rigid PVC conduit (ISI marked with valid CML No) not less than 20mm dia with all accessories including PVC insulated un sheathed 2.5 Sqmm cable with multistranded copper conductor (ISI marked with valid CML No) as connected to earth with dolly complete all as specified and as directed Note :- Cutting of wall and making good disturbed surface of wall shall be measured & paid sepertely.
S&F MCB DB, sheet metal enclosures double door SPN 4 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F, MCB SPN 63 Amps, 240 volts 'C' series 16 KA, including connection with suitable size copper lugs complete all as specified and directed.
S&F, MCB SP 240 volts, 6 to 40 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW of capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece with PVC Connection of any make with (ISI Mark) having 10 mm dia, 60 cm long with steel reinforcement suitable for hot & cold water geyser outlet supply with 02 nos of unions/cup shaped cover with washers complete all as specified and directed.
S&F sheet metal Enclosure with socket Plug top and earth plug, single pole and neutral with single pole MCB 20 Amps 240 volts complete all as specified and directed.
M&L sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 volts grade, 4 Sqmm size with multi stranded copper conductor (ISI marked with valid CML No), drawn in and including surface mounted non metallic rigid PVC conduit (ISI marked with valid CML No) not less than 25mm dia or Casing capping with all accessories including PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor (ISI marked with valid CML No) as connected to earth with Cutting of wall and making good disturbed surface of wall complete all as specified and directed.
M/S MAHAVIR SINGH (BID ID -3181855)
M/s Sree Baba Traders (BID ID -3177471)
M/s Ratan Lal Jain and Co. (BID ID -3180219)
M/s J.B. Construction (BID ID -3187114)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .