Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.3 L+₹69,846 (3.39%)Rejected-Finance | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹23.7 L+₹3.1 L (14.8%)Rejected-Finance | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical ADVERSE REMARK BY CHIEF ENGINEER CENTRAL COMMAND | |
| 5 | Rejected-Technical | - | Rejected-Technical FIRM UN ENLISTED BY REGISTERING AUTHORITY |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT
GE WEST DELHI CANTT
COMPREHENSIVE MAINTENANCE OF EM NATURE OF WORKS IN PIRU
2023_MES_587074_1
GE/DW-48/2023-24
Open Tender
Civil Works
Item Rate
270 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST DELHI CANTT
₹90,000
20 Jul 2023
10 May 2023
7 Jun 2023
10 May 2023
5 Jun 2023
24 May 2023
Amount
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power/call bell) complete and making good the disturbed surfaces of wall/floors/ceiling etc) and all fitting fixtures deposited to MES store Yard complete all as specfied & directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed /surface conduit, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing switches/sockets etc with cover plate/3mm thick plastic laminated sheet for the foiiowing complete all as specified and directed. :- (a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per item No. 2 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
S & F in Repair of socket 6 A 250V AC universal polycarbonate complete all as specified and directed.
S & F in Repair of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S & F in Repair of Bell push single pole one way complete all as specified and directed.
S & F in Repair of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S & F in Repair of Socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S & F in Repair of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduit on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
S&F in repair call bell electric 240 volts, AC supply, Ding Dong type complete all as specified and as directed.
M&L in repair louver shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB DP 20-40 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in replacement MCCB 4 pole 250 Amp, Icu = 35 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections all as specified and directed.
S&F replacement of lamp holder pvc/polycarbonate type with back plate complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in Replacement of MS down rod upto 1200 mm for fixing of ceiling fan all as specified and directed
S&F in Replacement of copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed.
M&L Replacement of MS outer shell with MS collar including indicator,safety nut & bolt suitable for geyser of capacity 25 ltr complete all as specified and directed.
Taking down ceiling/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store and refixng the same complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed.
M&L for rewinding exhaust fan of 300 mm sweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed.
S&F in replacement of exhaust fan motor of 300 mm sweep of any type & make complete with super enamelled copper wire (HTP) with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed.
S&F in replacement of outer body of exhaust fan of 300 mm sweep of any type & make complete provisions of new nuts pin complete all as specified & directed.
S&F in replacement of blade of exhaust fan of 300 mm sweep of any type & make complete provisions of new nuts pin complete all as specified & directed.
S&F in Replacement of of Desert Cooler copper fan motor upto cap - 1 to 2 HP complete all as specified .
S&F in Replacement of of Desert Cooler water pump upto cap 20 LPM and 6 mtr head complete all as specified .
S&F in Replacement of Desert Cooler Fan blade suitable for 1 to 2 HP motor including all new nut & bolts alongwith outer body made of 18 gauge sheet complete with front grill and 03 Nos side shutters made with same gauge sheet complete all as specified .
S&F in Replacement of of Desert Cooler water PVC tubing 10 mm dia & 01 set (three piece) of grass of suitable size complete all as specified .
M&L removing rusted iron particles by scrapping and applying two coats of aluminum spray painting to desret cooler inner and outer body including S&F in Replacement of of Air Cooler Cooling Pads set of three (conform to sample) with good holding of GI ties & PVC electric 1.5 sqmm copper cable jointing from motor and pump to panel board of cooler complete all as specified .
S&F in Replacement of Halozen Heating element Rod 400 watt capacity for Room heater (Make : Maharaja white line (lava)), including electric connections & testing complete all as specified .
S&F in Replacement of relay assembly/autocut for 1200 watt capacity Room heater complete all as specified.
S&F in Replacement of switch button (on/off) and turn button as per existing for Room heater 1200 watt capacity
S&F in Replacement of Halozen Heating element Rod for Room heater 1000 watt capacity including electric connections & testing complete all as specified .
S&F in Replacement of switch button (on/off) and turn button as per existing for Room heater 2000 watt capacity (Make : Baltra ) including electric connection and testing complete all as specified .
S&F in Replacement of Halozen Heating element Rod for Room heater 1000 watt capacity (Make : Gopi Heat pillar) including electric connections and testing complete all as specified .
S&F in Replacement of switch button (on/off) and turn button as per existing for Room heater 2000 watt capacity (Make : Gopi Heat pillar)including electric connections and testing complete all as specified .
S&F in Replacement of Compressor for Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Primary filters Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Secondry filters Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Minerals filter Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Condenser Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Drain tray Aquafresh RO plant 100 LPH capacity as per existing complete all as specified .
S&F in Replacement of Primary filters Aqua guard Hot & Cold (RO + UV) capcity 25 LPH as per existing complete all as specified .
S&F in Replacement of Secondry filters Aqua guard Hot & Cold (RO + UV) capcity 25 LPH as per existing complete all as specified .
S&F in Replacement of Minerals filter Aqua guard Hot & Cold (RO + UV) capcity 25 LPH as per existing complete all as specified .
S&F in Replacement of Primary filters Kent Elite (RO + UV) capcity 5 LPH as per existing complete all as specified .
S&F in Replacement of Secondry filters Kent Elite (RO + UV) capcity 5 LPH as per existing complete all as specified .
S&F in Replacement of Minerals filter Kent Elite (RO + UV) capcity 5 LPH as per existing complete all as specified .
Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 2. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 3. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape,screws,nut & bolts,washers,fan holding bushes, etc shall deemed to be included in the quoted rate of this item. 4.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 5. Contracror shall arrange suitable T&P such as Drill machine/cutter machine incl necessary for work and scaffolding and safety measures to make it functional complete all as specified and directed. 6. Contractor or his rep will report daily at complaint cell at Piru Vihar for collection of complaints from the concerned JE in charge . 7 Job slip & Complaint Register including stationary items as per sample shall be provided by the contractor free of cost. 8. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. 9.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,all materials except fixing accessories etc any capacityshall be issued by the department free for fixing and labour shall be paid unde respect items of this BOQ 10.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. 11.Old unserviceable material obtained from site against issued by the department to be deposited to MES store Yard. 12. The number of workers are required to be increased based upon number of complaints and quantum of work involved and during emergencies irrespective of working hours as decided by GE/Engr-in-Charge. 13. The number of workers are required to be increased based upon number of complaints and quantum of work involved and during emergencies irrespective of working hours as decided by GE/Engr-in-Charge. 14. The work inclludes attending complaints related to repair/replacement of parts and fixing of supply only items as enlisted in Sch'A' part-II including replacement of switches,sockets,ceiling roses,fan regulator,MCBS,LED fittings,elctic bell,holder,fan bearing,geyser element,CP connection,NEV of geysers,capacitors etc and all other electric works required to keep them fully functional to the entire satisfaction complete all as spd & directed by GE/Engr-in-charge 15. Labour charge for supply only items(55 to 95 of BOQ) will be paid under these items .
Supply only of MS down rod 300/450 mm for fixing of ceiling fan all as specified and directed
Supply only of Ceiling fan blade 1200mm sweep for fixing of ceiling fan all as specified and directed.
Supply only MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm swwep ceiling fan complete all as specified and as directed.
Supply only PVC connection with brass nippleof size 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25 lit capacity geyser as hot and cold connection complete all as specified and directed.
Supply only of inner shell copper body suitable for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only of inner shell Stainless steel body suitable for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only of Copper Heating Element 1500 /2000 watt including assembly suitable for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only of thermostat suitable to work at water temperature 30° to 75° C electric cut up for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only of Indicating lamp (red/green/yellow) complete suitable for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only 15A plug top 240V ACand connection complete all as specified and as directed
Supply only in Repair of socket 6 A 250V AC universal polycarbonate complete all as specified and directed.
Supply only of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
Supply only of Bell push single pole one way complete all as specified and directed.
Supply only of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
Supply only of Socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
Supply only of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
Supply only of SS combined 15 amp without Box complete all as specified and directed by Engr-in-charge
Supply only SS combined 15 amp with Box complete all as specified and directed by Engr-in-charge
Supply only SS combined 5 amp without Box complete all as specified and directed by Engr-in-charge
Supply only SS combined 5 amp with Box complete all as specified and directed by Engr-in-charge
Supply only call bell electric 240 volts, AC supply, Ding Dong type complete all as specified and as directed.
Supply only PVC flexible two core copper 1.5 sqmm size complete all as specified and directed.
Supply only Single core copper conductor 2.5 sqmm multistanded pvc insulated FRLS size complete all as specified and directed.
Supply only Single core copper conductor 1.5 sqmm multistanded pvc insulated FRLS size complete all as specified and directed.
Supply only Single core copper conductor 4.0 sqmm multistanded pvc insulated FRLS size complete all as specified and directed.
Supply only Single core copper conductor 6.0 sqmm multistanded pvc insulated FRLS size complete all as specified and directed.
Supply only saddle for fixing of conduit pipe as per site requirement including all connected items complete all as specified and directed.
Supply only LED LAMP 9 Watts pin type including taking any type of lamp all specified and directed
Supply only tube light fittings 20 watt 4 ft including taking any type of lamp allspecfied and directed
Supply only tube light fittings 10 watt 2 ft including taking any type of lamp all specfied and directed
Supply only lamp holder 240V AC pvc/polycarbonate type with back plate complete all as specified and directed.
Supply only ceiling fan capacitor 240V AC for 1200/1400 mm sweep 2.5 mfd all specfied and directed
Supply only canopy for ceiling fans (Set of two) complete all as specified and as directed.
Supply only ceiling rose 3 phase 240V AC pvc/polycarbonate isolated body complete all as specified and directed.
Supply only 3 mm thick hylum sheet 9x11 including cutting of suitable for switch/socket/regulator complete all as specified and directed.
Supply only 3 mm thick hylum sheet 8x5 including cutting of suitable for switch/socket complete all as specified and directed.
Supply only 3 mm thick hylum sheet 5x5 complete including cutting of suitable for switch/socketall as specified and directed.
Supply only metal thick sunken box 4x4 including brass screws and cup complete all as specified and directed.
Supply only metal thick sunken box 8x10 including brass screws and cup complete all as specified and directed.
Supply only metal thick sunken box 7x4 including brass screws and cup complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 429114.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum.
M/s Sohanil Construction
S.R. Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .