DGM
Indian Oil Corporation Limited, Post Box no 04, Viramgam. Ahmedabad 382150, Gujarat
Shifting of 1000 KVA LT DG set from WRPL Vadinar to WRPL Abu road
2021_WRVGM_133243_1
WRPL/VGM/TS/2020-21/124
Open Tender
Electrical Works
Works
90 days
IOCL, VADINAR AND IOCL VIRAMGAM
As per NIT Criteria
10 documents required · 10 mandatory
Exempted
11 May 2021
23 Mar 2021
15 Apr 2021
23 Mar 2021
14 Apr 2021
23 Mar 2021
Amount
Supply of 4CX16 mm²,A2XFY LT Cable FRLSH - Aluminium Cable-1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%
Supply of 3.5CX400 mm²,A2XFY LT Cable FRLSH - Aluminium Cable-1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%
Supply, laying & testing of 12 x 2.5 sq. mm. Cu. Control cable XLPE insulated, FRLS property on outer sheath, PVC sheathed armoured 1.1 kV grade control & power cables with copper / Aluminium conductor conforming to IS 7098 (P-1) latest edition including supply of lugs, glands, consummables, tools, tackles, labour complete.
Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all required materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
Power cables LT : OD upto 20 mm
Power cables LT : OD upto 20 mm to 40 mm
Power cables LT : OD above 60 mm
Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect.
50 mm X 6 mm G.I. earthing strip
Copper cable as per specifications - 100 Sq.mm
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge.
Supply, installation & fixing of prefabricated perforated GI cable trays of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, backfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cutting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including preparation of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of "EPILUX 610" Primer of M/s BERGER or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of concrete work).
Designing, providing, fabricating and fixing profiled sheeting 730-1020 mm cover width, 28-30 mm crests @ 186-333 mm centre to centre, manufactured out of 0.45 mm BMT (Base Metal Thickness) Hi-Tensile Steel (Minimum yield strength of 550 MPa) coated with hot dip metalic galvalume/ zincalume coating AZ-150 or equivalent as per AS:1397 and super polyster XRW quality paint coat as per AS/ NZS2728 (Category-3) of approved colour for roofing, cladding, gutters, rainwater pipes, spouts etc. The total mass of the coating on both sides shall be 150 gms/sqm (Zinc 45%/ Aluminium 55%). The total paint coat thickness shall be 35 microns, comprising of 20 microns exterior coat of super polyster XRW on top surface and 5 micron super polyester on back surface over 5 micron primer coats on both surfaces including side and end laps. The sheets shall have wide pans with 2-3 stiffening ribs for effective water shedding and special male/ female ends with full return legs on side laps for purlins support and anti-capilary flute in side lap. The sheets shall be fixed using polymer coated hot dip galvanised hex head self drilling fasteners as per AS:3566 (Class-3) on each crest of sheets for connection with purlins and polymer coated hot dipped stitching fasteners at 300 mm c/c on all sides and end laps, etc. Approved sealing tapes shall be used on side laps and end laps of sheets and closer to be provided at the last end of sheet. The measurement shall be based on per unit of finished/ laid area. Item to include curved sheets also wherever required. The Contractor shall give minimum 10 year guarantee for the sheets against deterioration, disintegration, loss of lustre, variation in colour, etc. and leakages across laps, fasteners etc. The Contractor is to submit design and shop drawing for approval on the sheet profile, design and details before installation :
Roof, side cladding, gable end cladding, gutters, rainwater pipes/ spouts etc. [Note: The area of sheet coverings shall be measured on the flat surface i.e. without allowance for laps and ribs].
Dismantling of 1000 KVA DG set at WRPL Vadinar as detailed below: a) Dismantling of acoustic enclosure or sound proof canopy. b) Dismantling of accessories on enclosure such as fans, lights, JBs, box etc. c) Dismantling of DG Set (Engine & Alternator) base frame from foundation. d) Dismantling of Vibration pads. e) Dismantling of Exhaust piping & silencer etc. f) Dismantling of fuel piping between DG set and fuel tank. g) Disconnecting batteries, power cables, control cables and others from engine. h) Dismantling of Diesel tank from foundation and disconnecting the fuel pipes. i) Dismantling of chimney structure. j) Disconnecting cable of alternator. k) Dismantling of AMF panel from foundation. l) Disconnecting all input/output cable from AMF panel m) Others dismantling as per site requirment
Shifting of 1000 KVA DG set from Vadinar to Abu road as detailed below: a) Providing transportation vehicle or vehicles as required for shifting of all dismantled items related to 1000KVA DG set from Vadinar station to Abu road station. b) Loading of dismantled acoustic enclosure or sound proof canopy, its frame and all other dismantled accessories associated with enclosure on transportation vehicle. c) Loading of dismantled DG set (Engine & alternator) with base frame and all the other dismantled accessories associated with engine and alternator on transportation vehicle. d) Loading of dismantled fuel piping and diesel tank on transportation vehicle. e) Loading of dismantled exhaust piping and chimney structure on transportation vehicle. f) Loading of dismantled AMF panel on transportation vehicle. g) Shifting of all the above items safely from Vadinar to Abu road. h) Safe Unloading of all the materials shifted from Vadinar to Abu road. i) Transiting insurance for the asset included j) Others shifting works as per site requirment
Installation of 1000KVA DG set at WRPL Abu road as detailed below: a) Installation of 1000 KVA DG set above Vibration pads on DG foundation. Scope also includes supply of new vibration pads (16 nos.), installation of pads on foundation and other works for installation. b) Installation of Fuel piping, exhaust piping, silencer, other accessories associated with DG Set etc. Scope also includes supply of studs, bolts etc and all necessary cutting, welding, fitting works. c) Installation of chimney structure. d) Installation of AMF Panel. Scope includes termination of control and power cables and other related works for installation. e) Installation of Sound Proof Canopy of Acoustic enclosure. Scope also includes installation of dismantled accessories associated with enclosure. f) Installation of Diesel Tank & associated fuel piping. g) Other instalaltion works as per site requirment
Servicing of DG set after Installation as detailed below: a. Supply and replace all filters for fuel, Lube Oil & air, b. Replacing lube oil (supply of lube oil in IOCL scope), c. Supply and replace coolant, d. Calibration of Fuel pump, Tapered settings, e. Inspection of cylinder heads, piston, f. Alignment of engine and alternator, g. Monitoring and mitigating vibration if high, cleaning of radiator and other works required for successful commissioning of the DG.
Commissioning of DG set a) Trial run of DG Set to be taken for 4 Hrs on Load condition. b) Monitoring and record all the critical parameters like Lube Oil Pressure, Lube Oil Temperature, Jacket Water Temperature, and Vibration etc. if any abnormalities observed during trial run; corrective action to be taken
Adarsh Electric Works
Patel electricals
ALDEN ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .