Palla wine Shop to Basantpur (Length 4900 Mtr.)
2026_HRY_550621_1
2026E2AA26CA 2D26 4E5D 9268 2A4FF89CD566284ULB
Open Tender
Civil Works
Works
730 days
Faridabad (MC)
2 documents required · 2 mandatory
₹20,000
₹59.5 L
Yes
Faridabad
26 Sept 2026
26 Sept 2026
27 Oct 2026
26 Sept 2026
24 Oct 2026
26 Sept 2026
6 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, supply, installation, testing, integration and commissioning of complete Adaptive Traffic Control System (ATCS) for traffic signal junctions, including all traffic signal controllers, camera-based vehicle detection and classification system, 300 mm LED red/amber/green signal heads, pedestrian red/green signal heads, digital countdown timers, power management/online DC-UPS system with battery backup, underground PVC insulated copper armored power/control cables of various cores and sizes, flexible copper cables, HDPE underground cable ducts of required diameters including trenchless road crossings, cable pulling, jointing and termination, junction boxes and connectors, MS standard and cantilever signal poles, RCC foundations including reinforcement, anchor bolts and base plates, metallic controller cabinets, communication/networking interface, GSM/Ethernet/IP connectivity, integration with ICCC/central traffic management system, all electrical and mechanical accessories, mounting brackets, glands, terminals, connectors, fasteners, earthing/protection arrangements, software/configuration, testing, calibration, commissioning, documentation and all associated civil, electrical, electronic and communication works, including all labour, materials, machinery, tools, transportation and incidental works necessary for complete and satisfactory operation, all as per approved drawings, technical specifications, applicable IS/EN standards and instructions of the Engineer-in-Charge. The scope shall also include operation and maintenance of the complete system for the specified DLP/AMC period, including preventive and corrective maintenance and replacement/repair of defective components, complete in all respects. | 1 | NO. | 1 | ₹1 |
| 2 | Memo No :- 45/HR/RC/E-5/2022-23/20210 dated 16.01.2024 Three Phase CCMS panels with 5 year warranty Supply and erection of 415V, 3 phase 4 wire outdoor type, degree of protection IP 55, Astronomical type, Microprocessor control system with time-of-day sequencing and Auto/manual facility, street light panel comprising of 125A MCCB as incomer and 4 no. 63 amp. MCB for outgoing, complete with internal wiring, 50x5 mm Al. Bus bar links, set of three 105/110Amp (AC 3 type). 80Amp. Contactors, one for individual phase, cable termination lugs for connecting outgoing cable of 4x25 sq. mm and 4x16 sq. mm XLPE cable, indication, metering, support channels etc., complete in all respect of CRCA sheet of thickness 2.5mm paint with PU. | 5 | Each | 1 | ₹5 |
| 3 | (23.28.14.16) LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy )135 lm/Watt) Supplying, installation, Testing and Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2
, P. F.=0.95, IP- 66,IK-10, CRI )80 , under voltage and over voltage protection,EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the
road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for
LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum
housing such that LED junction temperature shall not rise above 90°C). 120 W | 490 | Each | 1 | ₹490 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
BOQ_630397.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .