Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹39,937.26Admitted-Finance | -12.55% | ₹39,937.26 | L1 | Admitted-Finance |
| 2 | L2₹40,850.63+₹913.37 (2.29%)Admitted-Finance | -10.55% | ₹40,850.63+₹913.37 (2.29%) | L2 | Admitted-Finance |
| 3 | L3₹42,120.22+₹2,182.96 (5.47%)Admitted-Finance | -7.77% | ₹42,120.22+₹2,182.96 (5.47%) | L3 | Admitted-Finance |
| 4 | L4₹42,371.40+₹2,434.14 (6.09%)Admitted-Finance | -7.22% | ₹42,371.40+₹2,434.14 (6.09%) | L4 | Admitted-Finance |
| 5 | L5₹42,672.81+₹2,735.55 (6.85%)Admitted-Finance | -6.56% | ₹42,672.81+₹2,735.55 (6.85%) | L5 | Admitted-Finance |
Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
7 Jul 2026, 6:00 pmClosed
Suprintending Engineer
PHED Circle Baran
Annual Rate Contract for the Work of Drilling of 125 mm dia Tube Well for Hand Pumps as per departmental specification and installation of Hand Pumps complete with assembly and construction of platform as per specification and drawings approved by UN
2026_PHCJA_568965_1
Nit no 02/2026-27 PHED Division Chhabra
Open Tender
Civil Works
Percentage
364 days
Baran
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Executive Engineer PHED Division Chhabra
₹2.5 L
Yes
19 Sept 2026
17 Jun 2026
8 Jul 2026
17 Jun 2026
7 Jul 2026
17 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Handpump | - | - | - | - |
| 2 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | - | - | - | - |
| 3 | Nominal bore 125 mm dia. | - | Mtr | 455.93 | - |
| 4 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. | - | Mtr | 68.39 | - |
| 5 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. | - | - | - | - |
| 6 | 125 mm dia nominal bore | - | Mtr | 149.15 | - |
| 7 | Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)} medium of following sizes at site of work. | - | - | - | - |
| 8 | 125 mm dia NB( Thickness of pipe 4.8 mm & mass of tube 16.40 Kg/m) | - | Mtr | 1,358.47 | - |
| 9 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with
end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. | - | - | - | - |
| 10 | 125 mm dia | - | Each | 638.98 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
Tendernotice_2.pdf
PDF • 7.06 MB
BOQ_1012519.xls
BOQ • 0.28 MB
corri01.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .