Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
12 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE I RND Delhi
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF EXTERNAL ELECTRIFICATION TRANSFORMER VCB, LT PANELS, LT UG CABLE AND OTHER CONNECTED WORKS IN DIPAS, DIPR, CFEES AND RAC OF KWC AREA UNDER GE I RND DELHI
2026_MES_799753_1
GE/RND/T-64/DLI/2026-2027
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class D and Cat b(i)
2 documents required · 2 mandatory
₹500
Yes
GE I RND Delhi
₹82,000
Yes
21 Nov 2026
21 Nov 2026
19 Dec 2026
21 Nov 2026
12 Dec 2026
5 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dehydration and Filteration of 11 KV grade Transformer of capacity 1000 kVA oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achiving the dielectric strength to 40 KV for 1 minute with a sphare gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any kVA transformer etc complete all as specified and directed by Engineer-in-charge.
Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration. | 2 | Each Job | 100 | ₹200 |
| 2 | Dehydration and Filteration of 11 KV grade Transformer of capacity 750 kVA oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achiving the dielectric strength to 40 KV for 1 minute with a sphare gap of 2.5mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any kVA transformer etc complete all as specified and directed by Engineer-in-charge.
Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration. | 1 | Each Job | 100 | ₹100 |
| 3 | Dehydration and Filteration of 11 KV grade Transformer of capacity 500 kVA oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achiving the dielectric strength to 40 KV for 1 minute with a sphare gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any kVA transformer etc complete all as specified and directed by Engineer-in-charge.
Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration. | 1 | Each Job | 100 | ₹100 |
| 4 | Dehydration and Filteration of 11 KV grade Transformer of capacity 400 kVA oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achiving the dielectric strength to 40 KV for 1 minute with a sphare gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any kVA transformer etc complete all as specified and directed by Engineer-in-charge.
Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration. | 1 | Each Job | 100 | ₹100 |
| 5 | Taking out HT VCB/OCB,11 KV grade 400A rating from HT panel for servicing / repairs by dismantling the HT OCB operating mechanism, inspection of control wiring realignment of moving contacts with fixed contacts assembly, vacuum interrupter, checking of relays for protection, greasing of all moving parts of mechanism, checking and realignment of mechanism for its proper functioning and operation, re-assembling of HT VCB, fixed in its original position, testing for functions, and commissioning complete all as specified and directed by Engineer-in-charge. | 4 | Each Job | 100 | ₹400 |
| 6 | S&F of push button suitable for 400A OCB complete all as specified and directed. | 2 | Each | 100 | ₹200 |
| 7 | Calibration of 11 KV grade HT OCB/VCB relays of various types / Make by OEM through primary and Secondary injection method by bringing relay test kit, software PC system and other required measuring equipments to the site, after testing refixing to OCB 11 KV panel complete all as specified and directed by Engineer-in-charge.
Note- Certificate of this test will be provided by the contractor free of cost. | 13 | Each Job | 100 | ₹1,300 |
| 8 | Testing of HT current transformer (set of three) through primary current injection method and also checking the connected panel wiring by bringing required test kit and other required testing equipment and also checking tripping and closing operation complete all as specified and directed by Engineer-in-charge. | 8 | Each Job | 100 | ₹800 |
| 9 | Supply, installing, testing, commissioning of 11 KV grade HT OCB current transformer in replacement CT of 11 KV grade with CT ratio 300/150/5-5 fixed with HT OCB 11 KV including necessary cable connection etc suitable for fixing in HT panel board of any make including modification required at site to be carried to fix CT upto recess/coils including removing the burnt CTs complete all as specified and directed. | 8 | Each | 100 | ₹800 |
| 10 | M&L for checking of Potential Transformer by conducting ratio test/meggering for IR values, provided in OCBs 11 KV feeders checking of control wiring meters, relay and tripping system complete all as specified and directed by Engineer-in-charge. | 1 | Each Job | 100 | ₹100 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
TDR.pdf
Tender Documents • 1.32 MB
BOQ_897321.xls
BOQ • 0.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .