| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹40.6 L+₹561.21 (0.01%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹41.5 L+₹83,215.80 (2.05%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹42.7 L+₹2.0 L (4.99%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹42.9 L+₹2.3 L (5.60%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
21 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
PROVN OF EXTERNAL ELECTRIC SUPPLY TO OP SHELTERS AT TEZU MIL STN UNDER GE LEKHAPANI
2022_MES_557388_2
84109E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE LEKHAPANI
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE LEKHAPANI
₹87,000
Yes
9 Dec 2022
5 Nov 2022
24 Nov 2022
5 Nov 2022
21 Nov 2022
16 Nov 2022
5 Nov 2022 - 10 Nov 2022
Amount
Supplying, installing, connecting, testing & commissioning of distribution transformer of capacity 200 kVA, oil immersed type, step down, copper winding, outdoor type, ONAN type cooling, connection symbol Dyn11, HT winding with delta connected, LT winding with star connected with neutral brought out, HT (11 KV, 3 Phase, 50 Hz), LT (433 Volts 3 Phase 4 wire), with off load tapings on HT side to vary secondary voltage to ± 2.5% /± 5% /±7.5% within limit all as per IS-1180 (Part-I) 2014 with amt No. 1, 2 , 3 and 4, energy efficiency level No 3 with HT Vable box and LT cable Box, complete with all fittings, accessories and item, including plinth mounting of transformer, insulation level conforming to relevant IS and rated impedance including first filing of Transformer oil conforming to IS 335- 1993 and of dielectric strength 42 KV/cm (RMS) minimum and all other fitting etc (platform for mounting of transformer made up of PCC 1:2:4 20mm graded stone aggregate, solid block and making all faces fare using extra cement as per manufacturer design of required length, width and height in and including providing of 02 Nos ISMC 100 channel embedded in PCC of suitable length as directed at site by engr in chrage and including earth work work) complete as specified and as directed.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size coarse aggregate in pole coping or roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 240 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
M & L for steel tubular swaged pole 410 SP-22 (8.5 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
M & L for steel tubular swaged pole 410 SP-55 (11.0 metre long) seamless type, including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of bituminious paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed. Note- Earthwork shall be measured and paid seperately. Volume occupied by steel pole shall be deducted to derive the quantity of PCC.
S & F LED street lights nominal power 60 Watt LED, LED of Make as given in Apps 'B',, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-671-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Supply and fix Thermoplastic cable junction box for street lights of size 155 x 210 x92 mm made of high quality polycarbonate IP-66 (Weather Proof), incl 4 way bakelite cable terminals indl 03 Nos polymide gland, shock proof, rust free, corrosion free, chemical resistant, fire retardant having high impact (IK 08) totally insulated, UV resistant having high grade gasket made of polyurethane with including MCB SP 6 Amps- 01 Nos and 2 Nos M32 size cable gland suitable up to 10 Sqmm 4 core cable etc, complete all as specified and directed
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts complete all as directed by Engineer-in-charge including taking down old unserviceable.
S&F PVC insulated and round sheathed (flexible), multi standard aluminium conductor cable 1.5 Sqmm Weather proof cable to making hole if required on top and bottom of the steel pole etc complete all as specified and as directed
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 11 kV, rated voltage 12 kV, rated normal current 200 Amps, rated frequency 50 Hz, with 15 no of insulators, rated one minute power frequency withstand voltage between (i) earth & poles 28 kV (rms) (ii) across the isolating distance 32 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 kV (Peak) (ii) across the isolating distance 85 kV (Peak), Rated short-time withstand current 25 kA for 3 seconds, rated peak withstand current 63 kA for climatic conditions at the site, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
Supply and erection of lightning arrestor (set of 03), explusion type suitable for 11 kV continuous operating voltage (3 phase) with rated voltage 24 kV (rms) with nominal discharge capacity of 65 kA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed. Note- Lightning attester shall be able to withstand wind load of 196Kg/Sqm and seismic acceleration of 0.39g.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
S & F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
M & L in UG cable route indicator made out of PCC(1:2:4) 20mm graded stone of size 1m x 0.4m and thkness 0.1m as legs duly marked and painted for HT/LT cables including, complete all as specified and as directed.
Supplying & laying, in trenches 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying, in trenches 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supply & laying unreinforced precast concrete cable cover class HV type 2, flat shape, dimension 450 mm X 180 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core 95 sqmm complete all as specified and as directed.
S & F providing chain link fencing to the area of 4m x 4m and 2m height from the ground level around the transformer by using MS galvanized 3.18mm dia of wire and 50mm square size including wicket gate of size (2m x 2m) single leaf by using 50mm x 50mm 2.9 mm tubular section including line wire, rails, straining bolts etc with necessary binding wire, along with providing angle iron fencing post of size 65mm x 65mm x 6 mm with flat iron 50mm x 4mm placing intervals as directed including necesssary excavation, PCC (1:3:6) type C1 (using 20mm graded stone aggregate) return filling removal of surplus soil etc and applyimg two coats of synthethic enamel paint over a coat of red oxide primer on steel/ iron surfaces including all fixing accessories complete all as specified and as directed
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
FEBI CONSTRUCTION
M/S SINGH TRADERS
M/s HALDER ENTERPRISE
RIA CONSTRUCTION
STANDARD ELECTRIC WINDERS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .