| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-Finance LOWEST TENDERER | |
| 2 | L2₹42.1 L+₹6.3 L (17.7%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹44.9 L+₹9.1 L (25.5%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical WORK LOAD RETURN BY CHIEF ENGINEER PUNE ZONE PART-II DT 24 MAR 2021 WHETHER CONSIDERED CAPABLE OF HANDLING MORE WORK LOAD IS NO |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
8 Jun 2021, 6:00 pmClosed
Maj Komal Parihar
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPECIAL REPAIRS/REPLACEMENT OF ELECTRICAL WIRING BY REPLACING ALUMINIUM WIRING WITH COPPER WIRING AND ACCESSORIES IN BLDG NO P 282 P 283 P 284 P 285 P 479 P 480 AND SPECIAL REPAIR REPLACEMENT OF AC VENTILATION TRUNKING AND ASSOCIATED S
2021_MES_444414_1
GE/LONAVLA/8982/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹95,000
Yes
12 Jun 2021
20 May 2021
10 Jun 2021
20 May 2021
8 Jun 2021
25 May 2021
20 May 2021 - 23 May 2021
Amount
M&L for fixing single pointed air termination aluminium rod, 12mm dia 300 mm long complete all as specified and as directed.
M&L for fixing Aluminium strip 25 mmx 3 mm complete with saddles and fixing screw for fitting the strip complete all as specified and as directed. (Note:-Quoted rates are inclusive of drilling and new GI screws/nut bolts).
M&L for fixing GI strip 32 mm x 6 mm complete with saddles and fixing screw for fitting the strip complete all as specified and as directed. (Note:-Quoted rates are inclusive of drilling and new GI screws/nut bolts).
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and as directed
M&L for fixing of insulator BMD 40 for mounting of earth continuity conductor complete all as specified and as directed.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized earth plate with 32x6 mm thick GI strip by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia for watering, with funnel and wire mesh including testing on completion. All as specified and as directed incl dismentling existing unsv earthing of panel.
M&L for cement concrete Type B1 (1:2:4) 20 mm graded stone aggregate as in support blocks of size 150x150x150mm complete all as specified and as directed by EIC at site.
M&L for 40mm dia MS pipe bracket 450mm long with flange welded at the one end and arrangement for mounting of air termination rod at the other end complete all as specified and as directed.
S&F Supply/Return Air Duct with Fabricated rectangular square duct made out of 24 gauge GI sheet in shaped hollow profit including all accessories such as corner, carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete
S&F Supply/Return Air Duct with Fabricated rectangular square duct made out of 22 gauge GI Sheet in L shaped hollow profit including all accessories such as corner carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete.
Supply,Erection,Testing and commissioning of insulation comprising of the Duct Thermal insulation with 19mm thick closed cell elastomeric Nitrile Rubber closed celll, Class O fire rating
Supply & Fixing of Terminal Hepa Filter along with GI Terminal Box.
M & L for point wiring with 1.5 sq mm single core PVC insulated cable 1100 V grade with multistranded FRLS copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed FRLS copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheat concealed in the wall with 3 mm thick laminated sheet top cover/PVC Switch board mounted on wall for mounting the switches,socket outlets ,fan regulators etc all as a specified and direced for following. a) One 3 pin switch socket combination 5 Amp on independent board.
All as per item no 13 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm.
S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type.
S&F in repairs switch socket combination 2 in 1,5 amp flush type.
Supply & fix Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated complete with all fitment items (i.e. nut ,bolts , clamps etc) as specified and as directed.
Supply & fix Supply and fix Water heater storage type, electric,capacity 50 litres.BEE 5 star rated complete with all fitment items (i.e. nut ,bolts , clamps etc) as specified and as directed.
Supply & fix Wall mounted fans 230 volts single phase Havells swing dezire oscillating 300 mm (light grey) with remote suitable for wall mounting complete with all fitment items (i.e. nut ,bolts , clamps etc) as specified and as directed.
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M & L for point wiring with 1.5 sq mm single core PVC insulated cable 1100 V grade with multistranded FRLS copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed FRLS copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheat concealed in the wall with 3 mm thick laminated sheet top cover/PVC Switch board mounted on wall for mounting the switches,socket outlets ,fan regulators etc all as a specified and direced for following. (a) One light point/fan point/ex fan point controlled by one 5 Amps switch one way
One 3 pin 5 Amp switch socket outlet on same board with accessories
All as per item no 2 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm..
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. Make: Anchor / Bajaj / Cona Note:- Taking down of swithches included in taking down point wiring .
S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type complete all as specified and as directed. Make : Anchor / Bajaj / Cona .
S&F in repair Switch socket combination 2 in 1, 3/5 pin, 5 Amp flush type universal complete all as specified and as directed. Make : Anchor / Bajaj / Cona
S&F in repair Switch socket combination 2 in 1, 3/5 pin, 5 and 15 Amp flush type universal complete all as specified and as directed. Make : Anchor / Bajaj / Cona
Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. Make : Anchor / Cona / Bajaj
S&F in repairs Distribution Board, 8 Way ,Double door complete all as specified and as directed. Make : Indo Asian cat part No. 811807[Optipro] / Standard / Havells
S & F MCB SP 6 to 32 Amps, 240 Volts, Gold plus MCB C Curve Make : Havells Indo Asian / Standard
S & F MCB, DP 32/40/63 Amps 415 Volts Gold plus MCB C Curve Make : Havells Indo Asian / Standard
S&F LED Lamp 9W Make Havells LHLDEUECNL8R009
S&F of Decorative ultra slim aluminium LED lighting fixture 36 W with high lumen output, environmental friendly, energy efficient ready to use pack complete with all accessories complete all as required at site and as directed by Engineer -in-Charge. Make : Havells, LHEXACP7IN1W036 or equivalent of Bajaj/Philips / Wipro
Supply & fix exhaust fans Turbo Force SP metal body complete with and accessories 230 V,300 mm sweep 900 rpm including taking down old u/s exhaust fan and deposited to MES store complete all as specified and as directed.Make : Havells Make : Havells
M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
(d) One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm
S&F in repair Bell push, flush type, 5 amp, Make : Anchor / Bajaj / Cona
S&F Bell Multi Music type Anchor / Bajaj / Cona
Supply & fix of LED building/street light of 45 watt along with fixture Make Bajaj CAT Part No BRLEP 45W LED V2 or equivalent to CG/Philips/Wipro complete all as specified and directed Note: Inluding all fitment items. (like, bracket , nut, bolt and screws etc)
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store
S&F in repair electronics type fan regulator ,120 W complete all as specified and as directed. Make: MK/Anchor (Roma)/ABB
S&F in repairs Distribution Board, 8 Way ,Double door complete all as specified and as directed. Make : Indo Asian cat part No. 811807[Optipro] / Standard / Havells
S & F MCB SP 6 to 32 Amps, 240 Volts, Gold plus MCB B Curve Make : Havells Indo Asian / Standard
S&F LED Lamp 9W Make Havells LHLDEUECNL8R009
Supply and fix in replacement of LED Tube light of 10 watt (2') with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:Bajaj CAT Part No BCLSB 10 NW (2ft) or equivalent to CG/Philips/Wipro complete all as specified and directed .
S&F of Decorative ultra slim aluminium LED lighting fixture 22 W with high lumen output, environmental friendly, energy efficient ready to use pack complete with all accessories complete all as required at site and as directed by Engineer -in-Charge. Make : Havells, LHEXBTP7IN1S022 or equivalent of Bajaj/Philips / Wipro
M&L for Opening of body cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for Ceiling fan 1200 / 1400 mm Sweep complete all as directed by Engineer-in-Charge.
Supply & fix exhaust fans metal body complete with and accessories 230 V,300 mm sweep including taking down old u/s exhaust fan and deposited to MES store complete all as specified and as directed. Make : Havells
Dismantling the existing energy Meters, MCCB / MCB Distribution boards by disconnecting the eletric supply connection and refixing at new or same location after carrying out repairs / replacement , reconnecting complete all as directed by EIC at site.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets/Aluminium snap grid
M&L for powder coated aluminium snap grid frame work for false ceiling, with aluminium angle 25mmx25mmx1.5mm fixed to perimeter of wall, Main 'T' runner 38mmx25mmx1.5mm and secondary/cross 'T' runner 25mmx25mmx1.5mm to be interlocked in such a way that the size of grid shall be 605mmx 605mm including 6mm dia GI hangers (upto 1200mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40x3mm, 60mm long and expansion hold fastners 12.5mm dia, 40mm long complete all as specified and as directed. Note:- The thickness of the powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE.
S&F for Plastic Ceiling tiles decorative surface of 595x595x7mm hot transfer printing and good dimensional stability when the temperature is below 45 degree and suitably fixed in false ceiling aluminium snap grid frame with staples or screws complete all as specified and as directed Make :- Adorn or Equivalent
M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of priming coat of alkali resistant priming paint and over a wall care putty applying evenly all over surfaces of wall complete all as specified and directed.
Taking down chowkats with shutters( without taking off shutters from the frame) exc1.5 sqm and n exc 4 Sqm each
S&F aluminium powder coated partions partly glazed and partly panneled with 12 mm thick MDF board in bottom panel and 5 mm thick tinned in top panels fixed with clips, aluminium beads, rubber gasket etc centre to centre distance of vertical member shall n. cxe 1.10 mtr using following powder coated aluminium section as given in "JINDAL" catalouge fixed to wall ,floor and ceiling by means of screws complete all as specified & as directed (a) SP -20048 (b) DP - 20047, (c) Glazing clips - 19352. Note :- The thickness of powder coating shall not be less than 0.50 micron and tint shall be as decided by GE.
M&L MDF Board both side laminated 12 mm thick exterior grade fixed in ceiling to timber/metal frame work with screws complete all as specified and directed by Engr in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding/backing coat complete all as specified and as directed.
S&F Non skid ceramic floor tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm in floors etc coloured with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement
All as per item No 10 hereinbefore but in skirting including 10mm thick plastering for backing coat in cement mortar 1:4
S&F Non skid ceramic floor tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors/skirting etc with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement
S&F Non skid ceramic floor tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade complete
All as per item No 13 hereinbefore but in skirting including 10mm thick plastering for backing coat in cement mortar 1:4
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc
SHAILENDRA B TULSANI
M/s S.D Construction Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .