| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Rejected due to not full fill the technical eligibility criteria |
| 4 | Rejected-Technical 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Rejected-Technical Rejected due to not full fill the technical eligibility criteria |
Tender Value
Refer Docs
EMD Value
₹6,700
Closing Date
12 Aug 2024, 12:00 pmClosed
Executive Engineer (EM) M-1
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
Providing and fixing of LED Lights and wiring with allied accessories at Gazipur SPS.
2024_DJB_260634_3
NIT No-13 EE (EM) M-I/ (24-25)
Open Tender
Electrical Works
Works
30 days
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c.50448339804
₹6,700
31 Aug 2024
5 Aug 2024
12 Aug 2024
5 Aug 2024
12 Aug 2024
5 Aug 2024
Supply of 70W LED flood light. Make-Polycab/bajaj/Havells/Crompton
Supply of 2 X 10 Sq. mm. Al Conductor Power Armoured Cable. Make:-Havelles/Kalinga/national.
Supply of led fitting luminaries with of capacity 22 W, 1×22 W FTL HF type Make - Havells/Bajaj/ Polycab
Supply of 600 mm. air circulators Fans. Make :- ( Bajaj / Havells / Crompton ).
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply of 600 mm. Exhaust Fans . Make :- ( Orient / Havells / Crompton ).
Wiring for light point/fan point/exhaust fan point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M S box & earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc as reqd. Group – C.1.8.3
Wiring for circuit / sub main wiring along with earth wire with the following. Sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 X 2.5 Sq. mm. + 1 X 2.5 Sq. mm. earth wire.1.14.2
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.1.12
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel MCB distribution board, 415 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator). 4 way (4 + 12) Doule Door.2.4.1
Supplying & Fixing 5 amp. to 32 amp. rating 240/415 V, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole. 2.10.1
Supplying & Fixing 5 amp. to 32 amp. rating 240/415 V, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole & neutral. 2.10.2
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required1.33
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.1.41
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Also for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.1.50.1 & 1.51
Shakti Trading Co.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .