Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
8 Oct 2026, 6:00 pm
Lt Col, Vikramjeet Singh Reen
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF 33/11 KV INSTALLATIONS AND DITRIBUTION NETWORK, POWER TRANSFORMERS, EARTHING, CONTROL CABLES, VCBS, INSULATORS AND PANELS ALONGWITH CONNECTING WORKS IN CANTT AREA UNDER GE (I) KANPUR
2026_MES_768057_2
GE(I)/KAN/T-15 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹96,000
Yes
24 Sept 2026
24 Sept 2026
15 Oct 2026
24 Sept 2026
8 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for HT / LT underground cable / pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed. | 188 | Cum | - | - |
| 2 | Returning filling of excavated soil after laying the cable with spreading leveling watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed. | 112 | Cum | 2 | ₹224 |
| 3 | Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed. | 76 | Cum | 3 | ₹228 |
| 4 | M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid. | 56 | Cum | 4 | ₹224 |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed. | 3,482.5 | Each | 5 | ₹17,412.5 |
| 6 | M&L for drilling manually in soft/loose/ hard soil under road ,pavement hard standing for protection of GI pipe up to 80mm dia complete all as specified and directed. Note Depth of bore shall not be more than 1 Mtr from ground level. | 30 | RM | - | - |
| 7 | Supply & laying in replacement of GI tubing of 80 mm bore dia, light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, on wall or pole incl fixing arrangement as directed, culvert etc of required length for cable protection complete all as specified and directed. | 30 | RM | 2 | ₹60 |
| 8 | Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning complete all as specified and directed.
Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. | 400 | RM | 3 | ₹1,200 |
| 9 | All as per item No 8.00 above but HT 11 KV cable of size 120 Sqmm complete all as specified and directed. | 470 | RM | 4 | ₹1,880 |
| 10 | All as per item No 8.00 above but HT 11 KV cable of size 185 Sqmm complete all as specified and directed. | 125 | RM | 5 | ₹625 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_886761.xls
BOQ • 2.13 MB
TenderdocumentsT15.pdf
Tender Documents • 0.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .