Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-Finance GALI NO 2 H NO 45 2ND FLOOR NANAK VIHAR COLONY LAL KUAN GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201009 | ₹15.8 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹22.4 L+₹6.5 L (41.3%)Rejected-Finance | ₹22.4 L+₹6.5 L (41.3%) | L2 | Rejected-Finance Not Being L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not admitted due to NO remarks in CE Delhi Zone WLR QE Dec 2025. Change in constitution involved. |
| Sl No | Description | Qty | Unit | M/s S.G. BUILDERS L2 | A K ENGINEERING COMPANY L1 |
|---|---|---|---|---|---|
| 1.00Note: (i) The contractor or his authorized representative shall report daily to the Complaint Cell for collection of complaints and The contractor shall be required to attend complaints as and when intimated by the department through complaint slip , VYNUS , telephone or any otherauthorised means of communication .If it is not possible to rectify the same within timeline specified below, the matter along with detailed reasons shall immediately be brought to the notice of the Engineer-in-Charge by the contractor or his representative. If the Engineer-in-Charge is satisfied with the justification furnished, no recovery shall be effected on this account. (ii) (a) All No Light / Power Supply complaints shall be attended to and rectified within 01 hour, commencing from the date and time of issue/intimation of the complaint. Failure to attend the complaint within the stipulated period shall attract a penalty of Rs. 120/- for delay up to 04 hours and Rs. 240/- for delay beyond 04 hours, which shall be recovered from the contractor's dues. (b) All other routine maintenance complaints covered under the contract shall be attended to and rectified within 24 hours, commencing from the date and time of issue/intimation of the complaint. In case the complaint is not rectified within the stipulated period, a penalty of Rs. 120/- per complaint per day or part thereof shall be recovered from the contractor's dues.. However, labour charges for items covered under “M&L”, “S&F”, and “In Repair” shall be deemed to be included in the respective quoted rates. (iii) Items under this contract are of day-to-day nature and the complete scope/site cannot be forecast or handed over to the contractor at one time. The contractor shall therefore arrange adequate manpower, materials, and resources as per site requirements. In case the contractor fails to provide the required skilled labour in accordance with the contract provisions, suitable recoveries/penalties shall be levied as applicable. | |||||
| 1.01(iv) In addition to the above, the contractor shall arrange and maintain all necessary T&P required for execution of the work, such as multimeter , necessary electrical tools bag, tape roll , washers and screws of all sizes, , drilling machine with bits, and the like, including necessary safety measures, complete all as specified and directed by the Engineer-in-Charge. (v) The cost of all the above arrangements, obligations, T&P, consumables, labour, safety measures, and incidental requirements shall be deemed to be included in the quoted rates of the respective items and no extra payment whatsoever shall be admissible on this account. | |||||
| 2.00 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 360 | RM | 19 ₹6,840 | 8 ₹2,880 Lowest |
| 3.00 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 180 | RM | 25 ₹4,500 | 13 ₹2,340 Lowest |
| 4.00 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 180 | RM | 39 ₹7,020 | 14 ₹2,520 Lowest |
| 5.00 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 6 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 90 | RM | 60 ₹5,400 | 17 ₹1,530 Lowest |
| 6.00 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 10 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 60 | RM | 89 ₹5,340 | 22 ₹1,320 Lowest |
| 7.00 | S&F in repair plastic laminated sheet top cover 3 mm thick of size 8"x5" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed. | 20 | Each | 25 ₹500 | 19 ₹380 Lowest |
| 8.00 | S&F in repair plastic laminated sheet top cover 3 mm thick of size 11"x9" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed. | 20 | Each | 35 ₹700 | 22 ₹440 Lowest |
| 9.00 | S&F in repair MS sunken box of size 8"x11" to fixing of switch board concealed with necessary screws and washers complete as per sample complete all as specified and as directed. | 20 | Each | 35 ₹700 | 28 ₹560 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Aug 2026, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIRS/REPLACEMENT OF UNSERVICEABLE WIRING, MCBs, MCCBS, DBs, LIGHTS, SUMMER AND WINTER APPLIANCES AT SHANKAR VIHAR P TYPE MD ACCN UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2026_MES_777065_1
GE/TOKEN-19/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹40,000
Yes
17 Sept 2026
7 Jul 2026
6 Aug 2026
7 Jul 2026
4 Aug 2026
21 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | (iv) In addition to the above, the contractor shall arrange and maintain all necessary T&P required for execution of the work, such as multimeter , necessary electrical tools bag, tape roll , washers and screws of all sizes, , drilling machine with bits, and the like, including necessary safety measures, complete all as specified and directed by the Engineer-in-Charge.
(v) The cost of all the above arrangements, obligations, T&P, consumables, labour, safety measures, and incidental requirements shall be deemed to be included in the quoted rates of the respective items and no extra payment whatsoever shall be admissible on this account. | - | - | - | - |
| 2 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 360 | RM | - | - |
| 3 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 180 | RM | - | - |
| 4 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 180 | RM | - | - |
| 5 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 6 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 90 | RM | - | - |
| 6 | S&F in repair PVC insulated FRLSH single core with stranded copper cable of size 10 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. | 60 | RM | - | - |
| 7 | S&F in repair plastic laminated sheet top cover 3 mm thick of size 8"x5" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed. | 20 | Each | - | - |
| 8 | S&F in repair plastic laminated sheet top cover 3 mm thick of size 11"x9" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed. | 20 | Each | - | - |
| 9 | S&F in repair MS sunken box of size 8"x11" to fixing of switch board concealed with necessary screws and washers complete as per sample complete all as specified and as directed. | 20 | Each | - | - |
| 10 | S&F in repair single phase motor AC 230V 1300 RPM copper wound suitable for exhaust fan of 230/300 mm sweep heavy duty including taking down of old louvers complete all as specified and as directed. | 70 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TenderpagesT19.pdf
Tender Documents • 0.90 MB
BOQ_870245.xls
BOQ • 0.39 MB
SchofCrediT19.pdf
Additional Documents • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .